Intraoperative Cone Beam Computed Tomography (CBCT) provides a reliable 3D anatomical context essential for interventional planning. However, its static nature fails to provide continuous monitoring of soft-tissue deformations induced by respiration, probe pressure, and surgical manipulation, leading to navigation discrepancies. We propose a deformation-aware CBCT updating framework that leverages robotic ultrasound as a dynamic proxy to infer tissue motion and update static CBCT slices in real time. Starting from calibration-initialized alignment with linear correlation of linear combination (LC2)-based rigid refinement, our method establishes accurate multimodal correspondence. To capture intraoperative dynamics, we introduce the ultrasound correlation UNet (USCorUNet), a lightweight network trained with optical flow-guided supervision to learn deformation-aware correlation representations, enabling accurate, real-time dense deformation field estimation from ultrasound streams. The inferred deformation is spatially regularized and transferred to the CBCT reference to produce deformation-consistent visualizations without repeated radiation exposure. We validate the proposed approach through deformation estimation and ultrasound-guided CBCT updating experiments. Results demonstrate real-time end-to-end CBCT slice updating and physically plausible deformation estimation, enabling dynamic refinement of static CBCT guidance during robotic ultrasound-assisted interventions. The source code is publicly available at https://github.com/anonymous-codebase/us-cbct-demo.
Figures & tables
Figure 1: System overview. (a) Rigid calibration between robotic ultrasound and CBCT. (b) Image-based registration refinement. (c) Deformation estimation with USCorUNet. (d) Deformation transfer for CBCT slice updating. Ultrasound examples from the in vivo arm dataset (c) and the CT-mapped phantom dataset (b,d) illustrate cross-domain applicability. Conf. map denotes confidence map.
Figure 2: Architecture of USCorUNet.
Figure 3: Bidirectional deformation estimation results. (a,b) In vivo arm examples (Dataset A); (c,d) probe-induced motion (Datasets B and D); (e) externally induced motion (Dataset B). Orange/yellow dashed lines indicate visual alignment guides for I0 , I1 . The color bar indicates flow direction (x/y).
Method
MAE ↓
NCC ↑
FB ↓
Fold(% ) ↓
Dice(% ) ↑
Baseline
RAFT
0.05±0.02
0.85±0.10
1.81±1.22
0.24±0.14
90.31±4.14
Ours
USCorUNet
0.05±0.02
0.85±0.09
0.85±0.57
0.13±0.10
90.62±3.76
Ablation Study
w/o Corr.
0.08±0.03
0.61±0.18
1.32±3.14
0.56±0.51
89.10±3.33
Table 1: Testset performance of the base model on Datasets A, averaged over both deformation directions ( I0→I1 , I1→I0 ) and reported as mean ± standard deviation. ↓/↑ indicate lower/higher is better. Best results are in bold.
Method
1 N
2 N
3 N
4 N
5 N
6 N
DefCor-Net
95.9±3.3
92.4±4.8
91.1±7.5
87.8±7.1
87.8±12.2
82.6±12.1
USCorUNet
95.4±2.6
94.1±2.4
94.0±3.6
93.2±1.8
89.8±1.5
87.5±1.2
Table 2: Bone-mask Dice under the force-stratified protocol of DefCor-Net [ 9 ] on Dataset A. Dice is reported for the I1→I0 direction.
Motion
Method
MAE ↓
NCC ↑
FB ↓
Fold(% ) ↓
Probe- induced
RAFT
0.03±0.01
0.94±0.03
1.03±2.27
0.23±0.14
Base model
0.04±0.01
0.84±0.08
0.84±0.65
0.15±0.11
Probe-adapted
0.03±0.01
0.93±0.03
0.33±0.28
0.09±0.10
Externally induced
RAFT
0.03±0.01
0.93±0.05
0.91±1.35
0.14±0.13
Base model
0.05±0.02
0.71±0.17
1.28±1.95
0.45±0.55
External-adapted
0.03±0.01
0.92±0.05
0.23±0.24
0.07±0.07
Table 3: Test-set performance of fine-tuned models on Datasets B–D (probe-induced) and Dataset B (externally induced), averaged over both directions.
Figure 4: CT1′ update results on two representative abdominal phantom cases (Dataset D) using USCorUNet, RAFT, and LC2-FFD ( CT0 : source; CT1 : target). Red/orange boxes indicate structural artifacts/severe deformation regions.
Model
MAE ↓
SSIM ↑
Dice (%) ↑
Timing (ms) ↓
USCorUNet
0.33 ± 0.04
0.22 ± 0.02
82.22 ± 10.54
11.25 ± 0.44
RAFT
0.34 ± 0.04
0.21 ± 0.03
79.86 ± 12.31
56.24 ± 1.78
LC2-FFD
0.33 ± 0.05
0.22 ± 0.03
58.91 ± 8.77
5764.26 ± 510.63
Table 4: Quantitative results for CBCT updating on Dataset D using ultrasound-based deformation estimation, with all three methods evaluated under identical conditions and runtime reported end-to-end.