cs.CVMar 12, 2026

High-Precision 6DOF Pose Estimation via Global Phase Retrieval in Fringe Projection Profilometry for 3D Mapping

Authors: Sehoon Tak, Keunhee Cho, Sangpil Kim, Jae-Sang Hyun

Organizations: Department of Mechanical Engineering, Yonsei University, Seoul 03722, South Korea. · Department of Artificial Intelligence, Korea University, Seoul

Abstract

Digital fringe projection (DFP) enables micrometer-level 3D reconstruction, yet extending it to large-scale mapping remains challenging because six-degree-of-freedom pose estimation often cannot match the reconstruction's precision. Conventional iterative closest point (ICP) registration becomes inefficient on multi-million-point clouds and typically relies on downsampling or feature-based selection, which can reduce local detail and degrade pose precision. Drift-correction methods improve long-term consistency but do not resolve sampling sensitivity in dense DFP point clouds.We propose a high-precision pose estimation method that augments a moving DFP system with a fixed, intrinsically calibrated global projector. Using the global projector's phase-derived pixel constraints and a PnP-style reprojection objective, the method estimates the DFP system pose in a fixed reference frame without relying on deterministic feature extraction, and we experimentally demonstrate sampling invariance under coordinate-preserving subsampling. Experiments demonstrate sub-millimeter pose accuracy against a reference with quantified uncertainty bounds, high repeatability under aggressive subsampling, robust operation on homogeneous surfaces and low-overlap views, and reduced error accumulation when used to correct ICP-based trajectories. The method extends DFP toward accurate 3D mapping in quasi-static scenarios such as inspection and metrology, with the trade-off of time-multiplexed acquisition for the additional projector measurements.

Figures & tables

Explore similar work

Jun 10, 2026

Spatially Coupled Phase-to-Depth Calibration for Fringe Projection Profilometry

In fringe projection profilometry (FPP), depth is commonly recovered by fitting a phase-to-depth relation independently at each camera pixel. Although such pixel-wise calibration achieves high local accuracy, neighboring pixels can acquire markedly different calibration functions even when they observe the same smooth surface, producing spatially inconsistent geometry and structured surface artifacts. We propose a spatially coupled phase-depth transformation in which all pixels share a single low-dimensional mapping-global phase scalars combined with affine spatial terms on the undistorted reference-camera grid-rather than independent per-pixel fits, optionally augmented by a bounded, spatially smooth correction field. We further introduce a native-grid pairing scheme that constructs phase-depth calibration pairs directly on the reference-camera grid: when depth supervision comes from a rectified active-stereo pipeline, planes are fitted in stereo 3D and sampled back onto the camera grid along native rays, so the phase maps are never rectified. On a dental target with high-resolution scanner ground truth, the proposed model attains point-to-surface RMSE comparable to an active-stereo reference (about 12μm aggregate) while substantially improving spatial coherence over pixel-wise polynomial and rational calibration, and reduces the runtime mapping to a few element-wise operations per pixel with negligible parameter storage.
Jun 16, 2026

Contact-Based Fringe Projection Profilometry for High-Resolution 3-D Surface Measurement of Reflective and Transparent Objects

This paper presents a contact-based 3-D surface measurement method based on a Digital Fringe Projection (DFP) system, belonging to the vision-based tactile sensing family pioneered by the commercially successful GelSight sensor. Such sensors have proven effective for robotic fingertip manipulation and contact sensing. However, because GelSight employs photometric stereo with RGB LEDs, it does not measure absolute depth directly but instead infers it by integrating estimated surface gradients, which can accumulate reconstruction errors; in addition, it becomes increasingly difficult to calibrate as the sensing area grows, and its depth accuracy is challenged on highly reflective or transparent objects. To overcome these drawbacks, we propose a fringe-projection-based contact measurement technique that performs triangulation-based 3-D reconstruction on a coated silicone contact surface, providing dense per-pixel surface geometry and full-field 3-D shape measurement over the contact region. By integrating high-accuracy digital fringe projection into the sensor, our approach simplifies calibration over larger areas and enhances depth precision for complex surfaces. Experimental results, including a direct comparison with a GelSight Mini sensor, a sphere-fitting accuracy evaluation, and an uncertainty analysis, confirm that the proposed method significantly improves the accuracy and stability of structured-light-based 3-D measurements, allowing reliable reconstruction of objects with diverse optical properties.
Jul 16, 2026

Ray-based phase error correction for miniaturized DOE projector-based FPP under single-directional hyperbolic projection

Fringe Projection Profilometry (FPP) systems using miniaturized DOE pro-jectors often suffer from severe phase artifacts due to nonlinear projection characteristics and limited pattern controllability. We propose a ray-based phase error correction framework that models phase artifacts along projection rays from the projector pinhole, incorporating projector geometry without re-lying on image-domain processing or neighboring pixels. A projector pinhole estimation method based on a single-directional hyperbolic fringe pattern is introduced, through which projector geometry can be recovered without stereo calibration. In addition, a data-efficient strategy constructs the re-finement model from a single calibration pose. Experiments on miniaturized DOE projector-based FPP systems demonstrate significant improvements in reconstruction accuracy under nonlinear projection conditions, confirming the robustness and physical consistency of the proposed approach.