Bayesian Uncertainty-Aware MRI Reconstruction
Organizations: Department of Computer Science, University of Exeter, UK · UCL Hawkes Institute, Department of Computer Science, University College London, UK
Abstract
We propose a novel framework for joint magnetic resonance image reconstruction and uncertainty quantification using under-sampled k-space measurements. The problem is formulated as a Bayesian linear inverse problem, where prior distributions are assigned to the unknown model parameters. Specifically, we assume the target image is sparse in its spatial gradient and impose a total variation prior model. A Markov chain Monte Carlo (MCMC) method, based on a split-and-augmented Gibbs sampler, is then used to sample from the resulting joint posterior distribution of the unknown parameters. Experiments conducted using single- and multi-coil datasets demonstrate the superior performance of the proposed framework over optimisation-based compressed sensing algorithms. Additionally, our framework effectively quantifies uncertainty, showing strong correlation with error maps computed from reconstructed and ground-truth images.
Figures & tables
| Under-sampling Ratio | |||||
|---|---|---|---|---|---|
| Method | 5% | 10% | 20% | 30% | 40% |
| IFFT | 19.85 2.8 | 15.32 2.5 | 12.08 2.2 | 9.72 1.8 | 7.67 1.5 |
| ADMM-Wav | 5.62 1.5 | 3.71 1.2 | 2.26 1.0 | 1.45 0.8 | 0.98 0.6 |
| ADMM-TV | 5.56 1.5 | 3.68 1.2 | 2.25 1.0 | 1.42 0.8 | 0.98 0.6 |
| MCMC-TV | 5.65 1.6 | 3.60 1.2 | 2.11 1.0 | 1.30 0.8 | 0.90 0.6 |
| SR | 5% | 10% | 20% | 30% | 40% |
|---|---|---|---|---|---|
| CC | 0.80 .068 | 0.79 .059 | 0.79 .051 | 0.75 .047 | 0.74 .045 |