Low-Field Magnetic Resonance Image Quality Enhancement using Undersampled k-Space and Out-of-Distribution Generalisation
Organizations: Department of Computer Science, University of Exeter, Exeter, United Kingdom · UCL Hawkes Institute, Department of Computer Science, University College London, London, United Kingdom
Abstract
Low-field magnetic resonance imaging (MRI) offers affordable access to diagnostic imaging but faces challenges such as prolonged acquisition times and reduced image quality. Although accelerated imaging via k-space undersampling helps reduce scan time, image quality enhancement methods often rely on spatial-domain postprocessing. Deep learning achieved state-of-the-art results in both domains. However, most models are trained and evaluated using in-distribution (InD) data, creating a significant gap in understanding model performance when tested using out-of-distribution (OOD) data. To address these issues, we propose a novel framework that reconstructs high-field-like MR images directly from undersampled low-field MRI k-space, quantifies the impact of reduced sampling, and evaluates the generalisability of the model using OOD. Our approach utilises a k-space dual channel U-Net to jointly process the real and imaginary components of undersampled k-space, restoring missing frequency content, and incorporates an ensemble strategy to generate uncertainty maps. Experiments on low-field brain MRI demonstrate that our k-space-driven image quality enhancement outperforms the counterpart spatial-domain and other state-of-the-art baselines, achieving image quality comparable to full high-field k-space acquisitions using OOD data. To the best of our knowledge, this work is among the first to combine low-field MR image reconstruction, quality enhancement using undersampled k-space, and uncertainty quantification within a unified framework.
Figures & tables
| Domain | Metric | 100% | 50% | 30% |
|---|---|---|---|---|
| Pseudo-radial Sampling | ||||
| Low-Field (LF) | SSIM | 0.7466 0.0495 | 0.3070 0.0727 | 0.2606 0.0565 |
| PSNR | 21.80 1.9568 | 17.76 0.6992 | 17.72 0.7950 | |
| sIQT | SSIM | 0.8163 0.0496 | 0.8081 0.0539 | 0.8077 0.0587 |
| PSNR | 24.74 1.6038 | 24.01 2.071 | 23.64 2.5127 | |
| kIQT | SSIM | 0.8219 0.0550 | 0.8159 0.0675 | 0.8138 0.0725 |
| Methods | Metric | OOD |
| Low-Field (LF) | SSIM | 0.7466 0.0495 |
| PSNR | 21.80 1.9568 | |
| IQT-DDL | SSIM | 0.7660 0.0610 |
| PSNR | 24.25 0.823 | |
| sIQT | SSIM | 0.8163 0.0496 |
| PSNR | 24.74 1.6038 |