eess.IVMar 18, 2026

Deep Learning-Based Airway Segmentation in Systemic Lupus Erythematosus Patients with Interstitial Lung Disease (SLE-ILD): A Comparative High-Resolution CT Analysis

Authors: Sirong Piao, Ying Ming, Ruijie Zhao, Jiaru Wang, Ran Xiao, Rui Zhao, Zicheng Liao, Qiqi Xu, 

Organizations: Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China · Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. · Research and Development Center · Research and Development Center (RDC), Canon Medical Systems (China) , Beijing, China. · 

Abstract

To characterize lobar and segmental airway volume differences between systemic lupus erythematosus (SLE) patients with interstitial lung disease (ILD) and those without ILD (non-ILD) using a deep learning-based approach on non-contrast chest high-resolution CT (HRCT). Methods: A retrospective analysis was conducted on 106 SLE patients (27 SLE-ILD, 79 SLE-non-ILD) who underwent HRCT. A customized deep learning framework based on the U-Net architecture was developed to automatically segment airway structures at the lobar and segmental levels via HRCT. Volumetric measurements of lung lobes and segments derived from the segmentations were statistically compared between the two groups using two-sample t-tests (significance threshold: p < 0.05). Results: At lobar level, significant airway volume enlargement in SLE-ILD patients was observed in the right upper lobe (p=0.009) and left upper lobe (p=0.039) compared to SLE-non-ILD. At the segmental level, significant differences were found in segments including R1 (p=0.016), R3 (p<0.001), and L3 (p=0.038), with the most marked changes in the upper lung zones, while lower zones showed non-significant trends. Conclusion: Our study demonstrates that an automated deep learning-based approach can effectively quantify airway volumes on HRCT scans and reveal significant, region-specific airway dilation in patients with SLE-ILD compared to those without ILD. The pattern of involvement, predominantly affecting the upper lobes and specific segments, highlights a distinct topographic phenotype of SLE-ILD and implicates airway structural alterations as a potential biomarker for disease presence. This AI-powered quantitative imaging biomarker holds promise for enhancing the early detection and monitoring of ILD in the SLE population, ultimately contributing to more personalized patient management.

Explore similar work

Aug 28, 2026

Prompt-Guided Interactive Segmentation of Interstitial Lung Disease in Thoracic CT

Accurate segmentation of interstitial lung disease (ILD) patterns is essential for quantitative disease assessment and longitudinal monitoring. However, existing approaches remain limited by relying on dense annotations and producing static predictions that cannot be refined, motivating interactive approaches. While promptable models show promise in interactive segmentation, their adaptation to ILDs remains largely unexplored. To address this gap, we investigate prompt-guided foundation models for ILD refinement and present, to the best of our knowledge, the first adaptation of MedSAM2 for interactive 3D ILD segmentation on thoracic CT. We investigate three fine-tuning strategies and multiple clinically motivated prompts: bounding-boxes (BBox), point, lasso, and scribble. On a dataset spanning seven ILD patterns and healthy lung tissue, full model fine-tuning performed best, improving the average Dice score by 4.7 percentage points over MedSAM2.While BBox prompts achieve the strongest performance, non-native MedSAM2 interactions such as lasso and scribble prompts also prove effective. Finally, we present and evaluate a proof-of-concept end-to-end workflow in which MedSAM2 is initialized from an automatic segmentation prior and subsequently refined using radiologist prompts. Model weights and plug-ins made available at: https://github.com/AIHNlab/ILD-SemiSegTool.
Oct 12, 2026

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.
Jun 21, 2026

Human and AI collaboration for pulmonary nodule segmentation

Medical expert annotators are scarce, and blind reliance on artificial intelligence (AI) can be misleading, motivating approaches in which humans, particularly junior medical trainees or even non-medical personnel, collaborate with AI to achieve robust medical segmentation. Although the Segment Anything Model (SAM) shows promise for general-purpose image segmentation, its performance in human-AI collaboration for specialized medical tasks has not been thoroughly evaluated. Here we present Hi-Seg, a human-in-the-loop segmentation framework for pulmonary nodules built on SAM. Humans iteratively refine prompts through trial-and-error learning and semantic reasoning, progressively guiding SAM toward higher-quality masks. Using chest CT scans from 1,179 patients across 12 centers, we conducted the first large-scale external validation of collaborative human-SAM segmentation. Across all annotator groups, Hi-Seg achieved a mean Dice score of almost 85%, outperforming five state-of-the-art deep learning models by 10-22% and 13 SAM variants by 1-29%. Hi-Seg improved segmentation accuracy while reducing annotation time for medical annotators, and briefly trained non-medical annotators achieved performance comparable to that of the junior medical student. These findings suggest that human-in-the-loop segmentation can reduce clinician workload, enable scalable crowdsourced annotation, and transform clinical workflows by facilitating the safe and efficient integration of foundation models into routine clinical practice.