cs.CVMar 20, 2026

A Unified Platform and Quality Assurance Framework for 3D Ultrasound Reconstruction with Robotic, Optical, and Electromagnetic Tracking

Authors: Lewis Howell, Manisha Waterston, Tze Min Wah, James H. Chandler, James R. McLaughlan

Organizations: School of Computer Science, University of Leeds, Leeds, LS2 9JT · School of Electronic and Electrical Engineering, University of Leeds, Leeds, LS2 9JT · St James’s University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, LS9 7TF · Leeds Institute of Medical Research, University of Leeds, St James’ University Hospital, Leeds, LS9 7TF

Abstract

Three-dimensional (3D) Ultrasound (US) can facilitate diagnosis, treatment planning, and image-guided therapy. However, current studies rarely provide a comprehensive evaluation of volumetric accuracy and reproducibility, highlighting the need for robust Quality Assurance (QA) frameworks, particularly for tracked 3D US reconstruction using freehand or robotic acquisition. This study presents a QA framework for 3D US reconstruction and a flexible open source platform for tracked US research. A custom phantom containing geometric inclusions with varying symmetry properties enables straightforward evaluation of optical, electromagnetic, and robotic kinematic tracking for 3D US at different scanning speeds and insonation angles. A standardised pipeline performs real-time segmentation and 3D reconstruction of geometric targets (DSC = 0.97, FPS = 46) without GPU acceleration, followed by automated registration and comparison with ground-truth geometries. Applying this framework showed that our robotic 3D US achieves state-of-the-art reconstruction performance (DSC-3D = 0.94 +- 0.01, HD95 = 1.17 +- 0.12), approaching the spatial resolution limit imposed by the transducer. This work establishes a flexible experimental platform and a reproducible validation methodology for 3D US reconstruction. The proposed framework enables robust cross-platform comparisons and improved reporting practices, supporting the safe and effective clinical translation of 3D ultrasound in diagnostic and image-guided therapy applications.

Figures & tables

Explore similar work

Mar 1, 2026

MLRecon: Robust Markerless Freehand 3D Ultrasound Reconstruction via Coarse-to-Fine Pose Estimation

Freehand 3D ultrasound (US) reconstruction promises volumetric imaging with the flexibility of standard 2D probes, yet existing tracking paradigms face a restrictive trilemma: marker-based systems demand prohibitive costs, inside-out methods require intrusive sensor attachment, and sensorless approaches suffer from severe cumulative drift. To overcome these limitations, we present MLRecon, a robust markerless 3D US reconstruction framework delivering drift-resilient 6D probe pose tracking using a single commodity RGB-D camera. Leveraging the generalization power of vision foundation models, our pipeline enables continuous markerless tracking of the probe, augmented by a vision-guided divergence detector that autonomously monitors tracking integrity and triggers failure recovery to ensure uninterrupted scanning. Crucially, we further propose a dual-stage pose refinement network that explicitly disentangles high-frequency jitter from low-frequency bias, effectively denoising the trajectory while maintaining the kinematic fidelity of operator maneuvers. Experiments demonstrate that MLRecon significantly outperforms competing sensorless and sensor-aided methods, achieving average position errors as low as 0.88 mm on complex trajectories and yielding high-quality 3D reconstructions with sub-millimeter mean surface accuracy. This establishes a new benchmark for low-cost, accessible volumetric US imaging in resource-limited clinical settings.
Jul 14, 2026

Seeing Globally, Refining Locally: Global Visual Guidance and Local Ultrasound Cues for Robust Freehand 3-D Ultrasound Reconstruction

Freehand 3-D ultrasound (US) imaging has attracted increasing attention owing to its intuitive volumetric visualization, ease of use, and low cost. However, accurate 3-D reconstruction critically depends on stable probe pose estimation, yet existing trackerless methods remain susceptible to accumulated pose errors, particularly over long scanning trajectories. To address this limitation, we propose a global-to-local pose estimation framework that exploits external camera observations for globally stable localization and B-mode US images for anatomy-aware local refinement. Specifically, the framework comprises a dual-camera branch that performs contextual feature aggregation across camera views and temporal observations to estimate a globally consistent probe trajectory, and a B-mode branch that performs anatomical feature aggregation from sequential US images to capture tissue-dependent local motion cues. A cross-modal fusion module subsequently integrates the contextual camera features and anatomical US features to predict pose residuals and refine the camera-derived estimates in the transformation space. Furthermore, a multi-scale pose loss constrains relative motion over multiple temporal horizons to suppress accumulated drift during extended scans. The proposed framework is validated on phantom and in vivo datasets. On two in-house datasets (FUSION-J and FUSION-L) collected using different machines, the proposed US + Dual-Cam model reduces average trajectory drift to 1.67 mm and 1.29 mm, representing improvement of 16.50% and 27.12%, respectively, over a strong dual-camera baseline, while substantially outperforming US-only pose estimation (>13 mm drift). In in vivo forearm arteries reconstruction, it achieves Hausdorff distances of 1.58 mm, demonstrating the effectiveness of the proposed method on real clinical scenarios.
Sep 18, 2026

Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization

Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of 1.75±0.511.75\pm0.51 mm and 0.85±0.110.85\pm0.11 mm, respectively, compared with 1.72±0.511.72\pm0.51 mm and 0.84±0.120.84\pm0.12 mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE±\pmSD values of 0.41±0.350.41\pm0.35 mm for the cone and 0.50±0.410.50\pm0.41 mm for the triangular prism, closely matching the three-marker results of 0.40±0.350.40\pm0.35 mm and 0.48±0.400.48\pm0.40 mm, respectively.