HICT: High-precision 3D CBCT reconstruction from a single X-ray
Organizations: Zhejiang University · Angelalign Technology Inc.
Abstract
Accurate 3D dental imaging is vital for diagnosis and treatment planning, yet CBCT's high radiation dose and cost limit its accessibility. Reconstructing 3D volumes from a single low-dose panoramic X-ray is a promising alternative but remains challenging due to geometric inconsistencies and limited accuracy. We propose HiCT, a two-stage framework that first generates geometrically consistent multi-view projections from a single panoramic image using a video diffusion model, and then reconstructs high-fidelity CBCT from the projections using a ray-based dynamic attention network and an X-ray sampling strategy. To support this, we built XCT, a large-scale dataset combining public CBCT data with 500 paired PX-CBCT cases. Extensive experiments show that HiCT achieves state-of-the-art performance, delivering accurate and geometrically consistent reconstructions for clinical use.
Figures & tables
| Method | FDK | ASD | SART | NeRF | NAF | HiCT | ||||||
| Scene | PSNR | SSIM | PSNR | SSIM | PSNR | SSIM | PSNR | SSIM | PSNR | SSIM | PSNR | SSIM |
| Head | 25.16 | 0.7154 | 35.26 | 0.8106 | 34.87 | 0.8056 | 34.81 | 0.8618 | 35.32 | 0.9014 | 39.69 | 0.9880 |
| Chest | 22.89 | 0.6861 | 31.12 | 0.8421 | 32.17 | 0.8584 | 33.27 | 0.8629 | 32.30 | 0.9158 | 37.87 | 0.9719 |
| Leg | 24.47 | 0.6690 | 35.39 | 0.8213 | 35.29 | 0.8409 | 32.01 | 0.8557 | 36.57 | 0.9401 | 43.95 | 0.9978 |
| Carp | 22.31 | 0.7273 | 33.06 | 0.8337 | 36.74 | 0.8282 | 32.29 | 0.8490 | 38.16 | 0.9029 | 46.72 | 0.9902 |
| Foot | 23.02 | 0.7815 | 29.89 | 0.8209 | 30.29 | 0.8296 | 33.03 | 0.9312 | 31.63 | 0.9101 | 37.98 | 0.9403 |
| Method | PSNR | SSIM | LPIPS | IoU | Dice |
| RealFusion | 6.665 | 0.489 | 0.683 | 0.497 | 0.502 |
| Zero123 | 10.574 | 0.571 | 0.505 | 0.539 | 0.601 |
| Zero123++ | 11.925 | 0.668 | 0.442 | 0.640 | 0.623 |
| Zero123-XL | 13.052 | 0.691 | 0.423 | 0.698 | 0.670 |
| Stable-Zero123 | 15.129 | 0.701 | 0.396 | 0.733 | 0.737 |
| SyncDreamer | 16.262 | 0.742 | 0.283 | 0.769 | 0.792 |
| X-ray Sampling | RDA | PSNR ( ) | SSIM ( ) |
| ✗ | ✗ | 34.40 | 0.9223 |
| ✓ | ✗ | 36.13 | 0.9437 |
| ✗ | ✓ | 37.69 | 0.9502 |
| ✓ | ✓ | 39.21 | 0.9735 |