Accurate 3D dental imaging is vital for diagnosis and treatment planning, yet CBCT's high radiation dose and cost limit its accessibility. Reconstructing 3D volumes from a single low-dose panoramic X-ray is a promising alternative but remains challenging due to geometric inconsistencies and limited accuracy. We propose HiCT, a two-stage framework that first generates geometrically consistent multi-view projections from a single panoramic image using a video diffusion model, and then reconstructs high-fidelity CBCT from the projections using a ray-based dynamic attention network and an X-ray sampling strategy. To support this, we built XCT, a large-scale dataset combining public CBCT data with 500 paired PX-CBCT cases. Extensive experiments show that HiCT achieves state-of-the-art performance, delivering accurate and geometrically consistent reconstructions for clinical use.
Figures & tables
Figure 1: The pipeline of HiCT.
Method
FDK
ASD
SART
NeRF
NAF
HiCT
Scene
PSNR
SSIM
PSNR
SSIM
PSNR
SSIM
PSNR
SSIM
PSNR
SSIM
PSNR
SSIM
Head
25.16
0.7154
35.26
0.8106
34.87
0.8056
34.81
0.8618
35.32
0.9014
39.69
0.9880
Chest
22.89
0.6861
31.12
0.8421
32.17
0.8584
33.27
0.8629
32.30
0.9158
37.87
0.9719
Leg
24.47
0.6690
35.39
0.8213
35.29
0.8409
32.01
0.8557
36.57
0.9401
43.95
0.9978
Carp
22.31
0.7273
33.06
0.8337
36.74
0.8282
32.29
0.8490
38.16
0.9029
46.72
0.9902
Foot
23.02
0.7815
29.89
0.8209
30.29
0.8296
33.03
0.9312
31.63
0.9101
37.98
0.9403
Table 1: Comparisons on the 3D CBCT reconstruction task. The best and second-best results are marked in bold and underlined.
Figure 2: HiCT demonstrates excellent visual consistency and boundary clarity in the results of multi - view projection generation stage and 3D CBCT generation stage when compared with GT.
Method
PSNR
SSIM
LPIPS ↓
IoU
Dice
RealFusion
6.665
0.489
0.683
0.497
0.502
Zero123
10.574
0.571
0.505
0.539
0.601
Zero123++
11.925
0.668
0.442
0.640
0.623
Zero123-XL
13.052
0.691
0.423
0.698
0.670
Stable-Zero123
15.129
0.701
0.396
0.733
0.737
SyncDreamer
16.262
0.742
0.283
0.769
0.792
Table 2: Results of novel multi-view projections synthesis.
X-ray Sampling
RDA
PSNR ( ↑ )
SSIM ( ↑ )
✗
✗
34.40
0.9223
✓
✗
36.13
0.9437
✗
✓
37.69
0.9502
✓
✓
39.21
0.9735
Table 3: Ablation results respectively show the impact of density-driven X-ray mixed-sampling method and RDA on CBCT reconstruction quality.
Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries. We propose X-Splat, the first Gaussian Splatting framework for generating CBCT-like 3D dental volumes from a single PXR. X-Splat uses the known panoramic acquisition geometry as a generation scaffold: learnable anisotropic Gaussian primitives are initialized along the X-ray paths that formed the input image and adjusted in a single feed-forward pass, constrained by Beer-Lambert reprojection and multi-view radiographic training supervision. A lightweight residual refiner adds dataset-level anatomical priors without overriding the geometry already resolved by the Gaussians. We train on synthetic PXR-CBCT pairs, enabling direct volumetric supervision without paired real scans. We further introduce segmentation-based geometry-aware metrics, providing the first evaluation of PXR-based generation over maxillofacial anatomy. X-Splat outperforms NeRF- and GAN-based baselines, recovering individual teeth, cortical boundaries, and alveolar structure, including the mandibular canal which prior methods fail to reconstruct. Code will be available at https://github.com/tomek1911/X-Splat
Tomasz Szczepański, Szymon Płotka, Michal K. Grzeszczyk +2
Sano Centre for Computational Medicine, Poland · Jagiellonian University, Poland · Warsaw University of Technology, Poland +2
Panoramic radiograph (PR) is fundamentally used in routine dental care, but it inherently provides only a two-dimensional (2D) projection of complex three-dimensional (3D) craniofacial anatomy. Most existing learning-based methods attempt to computationally recover this 3D information by directly regressing native cone-beam computed tomography (CBCT) volumes from PR. However, this direct mapping requires the model to simultaneously learn common anatomical structures and patient-specific morphological variations. This entangled formulation makes the ill-posed 2D-to-3D inverse problem highly ambiguous, often producing over-smoothed reconstructions with blurred anatomical boundaries. To address this, we propose HyDAR-Pano3D, a two-stage framework that reformulates PR-to-CBCT reconstruction as a disentangled anatomical recovery problem. In Stage 1, a dual-encoder network integrates radiographic features with SAM-derived semantic priors to reconstruct an arch-normalized canonical volume. In Stage 2, an Anatomical Restoration Network predicts a prior-constrained structured deformation field to map this canonical volume back to the native space, restoring individual morphological variations. Experiments on three large-scale datasets show that HyDAR-Pano3D significantly outperforms baseline methods (p<0.05), achieving a 25.76 dB PSNR, 85.70% SSIM, and an 83.83% overall anatomical Dice score. The synthesized volumes successfully support downstream segmentation of whole teeth (82.4% Dice) and the inferior alveolar canal (72.2% Dice), demonstrating that our disentangled approach preserves clinically relevant structures to enable robust anatomy-aware assessment when CBCT data is unavailable.
Yaoyao Yue, Jérôme Schmid, Xiaoshuang Li +2
School of Computer Science, the University of Sydney, Australia · Geneva School of Health Sciences, HES-SO University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland · Department of Computer Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China +1
Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited availability. Standard chest X-rays are cost-effective and widely accessible, but provide only 2D projections with limited pathological information. Reconstructing 3D CT volumes from 2D X-rays could markedly increase diagnostic accessibility, yet existing methods rely predominantly on synthetic X-ray projections, limiting clinical generalization. We propose AXON, a multi-stage diffusion-based framework that reconstructs 3D CT volumes directly from real X-rays with substantially improved fidelity over existing approaches. AXON follows a coarse-to-fine paradigm: a Brownian Bridge diffusion model first captures global anatomical structure, and a ControlNet-guided refinement stage then enhances local intensity detail and anatomical realism. To alleviate the depth ambiguity inherent in 2D-to-3D reconstruction, AXON incorporates bi-planar X-ray views, enabling more accurate spatial reasoning and structural recovery. A dedicated super-resolution module further increases the spatial resolution of the generated volumes. Experiments on public and external datasets show that AXON consistently surpasses state-of-the-art approaches while generalizing across diverse clinical distributions. At our highest-resolution bi-planar setting, AXON achieves an 11.9% improvement in PSNR and an 11.0% increase in SSIM over the strongest baseline evaluated at that resolution. In the 1283 single-planar setting, it maintains a lead of 7.8% in PSNR on LIDC-IDRI, with larger margins on the external clinical dataset of 8.0% in PSNR and 16.9% in SSIM. Our code is available at https://github.com/ai-med/AXON/.
Martin Rath, Morteza Ghahremani, Yitong Li +3
Technical University of Munich (TUM), Germany · Munich Center for Machine Learning (MCML), Germany · University of Western Australia (UWA), Australia