cs.AIApr 6, 2026

MedGemma 1.5 Technical Report

Authors: Andrew Sellergren, Chufan Gao, Fereshteh Mahvar, Timo Kohlberger, Fayaz Jamil, Madeleine Traverse, Alberto Tono, Bashir Sadjad, 

Abstract

We introduce MedGemma 1.5 4B, the latest model in the MedGemma collection. MedGemma 1.5 expands on MedGemma 1 by integrating additional capabilities: high-dimensional medical imaging (CT/MRI volumes and histopathology whole slide images), anatomical localization via bounding boxes, multi-timepoint chest X-ray analysis, and improved medical document understanding (lab reports, electronic health records). We detail the innovations required to enable these modalities within a single architecture, including new training data, long-context 3D volume slicing, and whole-slide pathology sampling. Compared to MedGemma 1 4B, MedGemma 1.5 4B demonstrates significant gains in these new areas, improving 3D MRI condition classification accuracy by 11% and 3D CT condition classification by 3% (absolute improvements). In whole slide pathology imaging, MedGemma 1.5 4B achieves a 47% macro F1 gain. Additionally, it improves anatomical localization with a 35% increase in Intersection over Union on chest X-rays and achieves a 4% macro accuracy for longitudinal (multi-timepoint) chest x-ray analysis. Beyond its improved multimodal performance over MedGemma 1, MedGemma 1.5 improves on text-based clinical knowledge and reasoning, improving by 5% on MedQA accuracy and 22% on EHRQA accuracy. It also achieves an average of 18% macro F1 on 4 different lab report information extraction datasets (EHR Datasets 2, 3, 4, and Mendeley Clinical Laboratory Test Reports). Taken together, MedGemma 1.5 serves as a robust, open resource for the community, designed as an improved foundation on which developers can create the next generation of medical AI systems. Resources and tutorials for building upon MedGemma 1.5 can be found at https://goo.gle/medgemma.

Figures & tables

Appendix figures & tables9 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Oct 14, 2026

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration
May 9, 2026

MultiMedVision: Multi-Modal Medical Vision Framework

Multi-modal medical imaging enables comprehensive diagnostics, yet current foundation models process 2D (e.g. X-ray) and 3D (e.g. CT) data with separate, dimensionality-specific architectures. We present MultiMedVision, a unified framework for joint 2D/3D representation learning built on a Sparse Vision Transformer. Our model uses 3D Rotary Positional Embeddings and variable-length sequence packing to process mixed-modality batches natively within a shared latent space, without modality-specific adapters or treating 3D volumes as 2D slice sequences. Trained with a self-supervised objective on chest X-rays (MIMIC-CXR) and CT scans (CT-RATE), and using a single shared encoder with 5x less data, MultiMedVision achieves competitive performance on both 2D benchmarks (Macro AUROC 0.82 on MIMIC, 0.84 on CheXpert) and 3D tasks (0.85 on CT-RATE). Analysis of the learned representations reveals coexisting modality-specific and shared feature subspaces, demonstrating that unified cross-dimensional representation learning is feasible without sacrificing modality-specific performance.
Apr 14, 2026

Medical thinking with multiple images

Large language models perform well on many medical QA benchmarks, but real clinical reasoning often requires integrating evidence across multiple images rather than interpreting a single view. We introduce MedThinkVQA, an expert-annotated benchmark for thinking with multiple images, where models must interpret each image, combine cross-view evidence, and answer diagnostic questions with intermediate supervision and step-level evaluation. The dataset contains 8,067 cases, including 720 test cases, with an average of 6.62 images per case, substantially denser than prior work, whose expert-level benchmarks use at most 1.43 images per case. On the test set, the best closed-source models, Claude-4.6-Opus, Gemini-3-Pro, and GPT-5.2-xhigh, reach only 57.2%, 55.3%, and 54.9% accuracy, while GPT-5-mini and GPT-5-nano reach 39.7% and 30.8%. Strong open-source models lag behind, led by Qwen3.5-397B-A17B at 52.2% and Qwen3.5-27B at 50.6%. Further analysis identifies grounded multi-image reasoning as the main bottleneck: models often fail to extract, align, and compose evidence across views before higher-level inference can help. Providing expert single-image cues and cross-image summaries improves performance, whereas replacing them with self-generated intermediates reduces accuracy. Step-level analysis shows that over 70% of errors arise from image reading and cross-view integration. Scaling results further show that additional inference-time computation helps only when visual grounding is already reliable; when early evidence extraction is weak, longer reasoning yields limited or unstable gains and can amplify misread cues. These results suggest that the key challenge is not reasoning length alone, but reliable mechanisms for grounding, aligning, and composing distributed evidence across real-world multimodal clinical inputs.