cs.LGApr 20, 2026

Parkinson's Disease Detection via Self-Supervised Dual-Channel Cross-Attention on Bilateral Wrist-Worn IMU Signals

Authors: Meheru Zannat

Organizations: Khulna University of Engineering & Technology (KUET), Bangladesh

Abstract

Parkinson's disease (PD) is a chronic neurodegenerative disease. It shows multiple motor symptoms such as tremor, bradykinesia, postural instability, freezing of gait (FoG). PD is currently diagnosed clinically through physical exam by health-care professionals, which can be time consuming and highly subjective. Wearable IMU sensors has become a promising gateway for passive monitoring of PD patients. We propose a self-supervised cross-attention encoder that processes bilateral wrist-worn IMU signals from a public dataset called PADS, consisting of three groups, PD (Parkinson Disease), HC (Healthy Control) and DD (Differential Diagnosis) of a total of 469 subjects. We have achieved a mean accuracy of 93.12% for HC vs. PD classification and 87.04% for PD vs. DD classification. The results emphasize the clinical challenge of distinguishing Parkinson's from other neurodegenerative diseases. Self-supervised representation learning using contrastive infoNCE loss gained an accuracy of 93.56% for HC vs. PD and 92.50% for PD vs. DD using only 20% of labelled data. This demonstrates the effectiveness of our method in transfer learning for clinical use with minimal labels. The real-time applicability was tested by deploying the optimized model with a mean inference time of 48.32 ms per window on a Raspberry Pi CPU.

Explore similar work

Sep 9, 2026cs.CV

Freezing of Gait Prediction Under Spatial Occlusion: An IMU-Supervised Cross-Modal Distillation Approach

Parkinson's disease is a progressive neurodegenerative disorder characterised by gradual deterioration of movement control. Automated freezing-of-gait (FOG) detection supports the objective assessment of gait-related motor impairment. Two common approaches are used for FOG prediction: (i) analysing video recordings of the patient's movements and (ii) analysing data collected using inertial measurement unit (IMU) wearable sensors attached to the patient's lower limbs. Video-based approaches may suffer detection errors during continuous turning-in-place tasks because the lower limbs undergo substantial geometric self-occlusion, degrading pose-estimation accuracy. IMU-based approaches are generally less affected by visual occlusion; however, they are difficult to deploy outside clinical or laboratory settings, as the sensors must be attached securely and remain in place throughout the assessment. Motivated by this, we propose a cross-modal subspace distillation framework to mitigate the limitations of unimodal FOG detection by combining IMU accuracy with video-based practicality. We extract invariant latent topologies from a pre-trained kinematic oracle to structurally supervise a non-encoded visual architecture during training. To resolve periods of severe spatial occlusion, a dual-stream visual model probabilistically fuses skeletal graph nodes and continuous spatial pixels, dynamically shifting reliance to uninterrupted pixel boundaries as joint tracking confidence drops. Evaluated against a public, multi-modal sequence dataset of Parkinson's individuals executing continuous 360360^\circ turns, empirical results demonstrate that applying sensory boundary topologies strictly mitigates tracking evaluation entropy. Our constrained optimisation confirms that highly precise FOG prediction bounds can be achieved over zero-wearable inference environments.
Chandan Biswas, Aryan Singh, Anabik Pal
Sep 8, 2026cs.CV

Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism

Objective assessment of Freezing of Gait (FoG) in Parkinson's disease (PD) relies predominantly on wearable Inertial Measurement Units (IMUs). While IMUs provide optimal kinematic precision, mandatory sensor attachment restricts continuous clinical deployment. Conversely, unobtrusive vision-based alternatives suffer substantial classification errors during turning-in-place tasks, where geometric self-occlusion degrades deterministic skeletal coordinates and obscures the high-frequency precursors required for FoG detection. To resolve these physical observation limits, we propose a supervised cross-modal subspace distillation framework. During optimisation, pre-trained kinematic data from IMU sensors and contextual clinical metadata act as oracles to guide a deployable visual architecture. By incorporating joint velocity and acceleration derivatives, utilising a confidence-based gating mechanism, the visual model mitigates some of the tracking errors during occlusion events. Empirical evaluations confirm this latent alignment transfers the predictive fidelity of hardware sensors directly into the visual representation, yielding 85.5%85.5\% accuracy, and 82.4%82.4\% balanced accuracy. All the while maintaining a vision only model at inference.
Aryan Singh, Chandan Biswas
Jun 8, 2026cs.SD

Multi-View Speech Representation Learning for Parkinson's Disease Detection Using Context-guided Cross-modal Attention

Parkinson's disease (PD) is a progressive neurodegenerative disorder that frequently causes speech impairments associated with hypokinetic dysarthria. As speech production relies on the precise coordination of complex neuromuscular mechanisms, speech analysis has emerged as a promising non-invasive and cost-effective biomarker for early PD detection. Recent deep learning approaches have shown encouraging results; however, most existing methods rely on a single speech representation, potentially overlooking complementary pathological information encoded across different feature spaces. In this work, we propose a multi-branch deep learning framework for automatic PD detection from speech. Each recording is segmented into 5-second chunks and represented using three complementary modalities: Log-Mel spectrograms, MFCCs, and HuBERT embeddings extracted from raw waveforms. The spectrograms are processed using a pre-trained ResNet-18 encoder, MFCC sequences are modeled through a BiLSTM network, and raw speech is encoded using a pre-trained HuBERT model. To effectively integrate these heterogeneous representations, we introduce a context-guided cross-modal attention mechanism that dynamically weights temporal HuBERT embeddings according to the global acoustic context derived from the spectrogram and MFCC branches. Experiments conducted on the publicly available Spanish PC-GITA corpus under strict speaker-independent 5-fold cross-validation demonstrate the effectiveness of the proposed approach. The proposed architecture achieves an accuracy of 91.51%, an F1-score of 91.24%, and an AUC of 95.97%. Furthermore, ablation studies confirm the contribution of both the proposed context-guided cross-modal attention mechanism and the integration of complementary speech representations. These findings highlight the potential of heterogeneous speech modeling for robust and clinically reliable PD detection.
George Theodosiou, Loukas Ilias, Dimitris Askounis