cs.CVApr 30, 2026

Stop Holding Your Breath: CT-Informed Gaussian Splatting for Dynamic Bronchoscopy

Authors: Andrea Dunn BeltranDaniel RhoAarav MehtaXinqi XiongRaúl San José EstéparRon AlterovitzMarc NiethammerRoni Sengupta

Organizations: University of North Carolina at Chapel Hill · 2Harvard Medical School · University of California, San Diego

Abstract

Bronchoscopic navigation relies on registering endoscopic video to a preoperative CT scan, but respiratory motion deforms the airway by 5-20 mm, creating CT-to-body divergence that limits localization accuracy. In practice, this is mitigated through breath-hold protocols, which attempt to match the intraoperative anatomy to a static CT, but are difficult to reproduce and disrupt clinical workflow. We propose to eliminate the need for breath-hold protocols by leveraging patient-specific respiratory modeling. Paired inhale-exhale CT scans, already acquired for planning, implicitly define the patient-specific deformation space of the breathing airway. By registering these scans, we reduce respiratory motion to a single scalar breathing phase per frame, constraining all reconstructions to anatomically observed configurations. We embed this representation within a mesh-anchored Gaussian splatting framework, where a lightweight estimator infers breathing phase directly from endoscopic RGB, enabling continuous, deformation-aware reconstruction throughout the respiratory cycle without breath-holds or external sensing. To enable quantitative evaluation, we introduce RESPIRE, a physically grounded bronchoscopy simulation pipeline with per-frame ground truth for geometry, pose, breathing phase, and deformation. Experiments on RESPIRE show that our approach achieves geometrically faithful reconstruction, over 20x faster training, and 1.22 mm target localization accuracy (within the 3mm clinically relevant tolerances) outperforming unconstrained single-CT baselines. Please check out our website for additional visuals: https://asdunnbe.github.io/RESPIRE/

Explore similar work

Aug 7, 2026cs.CV

Geometry-Aware Camera Localization for Bronchoscopy

Camera localization in bronchoscopy remains a challenging problem due to stringent accuracy requirements, real-time constraints, and limited training data. Compared to natural scenes, the confined anatomical structures demand millimeter-level precision, while intraoperative guidance necessitates low-latency inference. However, existing methods often fail to effectively exploit preoperative geometric priors, limiting their robustness and accuracy. To address these limitations, we propose a unified geometry-aware bronchoscope localization framework (GABL) that effectively fuses preoperative structural priors with paired intraoperative video to estimate 6-DoF camera poses. Specifically, to address visual ambiguity in complex airways, we propose a graph-guided coarse-to-fine localization scheme that effectively leverages structural priors for precise pose estimation. Furthermore, to mitigate pose jitter and bridge the visual-structural gap, we integrate a Transformer-based tracking model with a novel RGB-depth matching objective, jointly enforcing spatio-temporal and geometric consistency. Extensive experiments demonstrate that our method yields remarkable reductions of 8.37% and 31.76% in translation and rotation errors over the prior state-of-the-art, alongside 4 times inference speedup (33.6 FPS) for robust real-time bronchoscope localization. Project website: https://paulili08.github.io/GABL/.
Lumin Chen, Qingyao Tian, Jinpeng Li +5
Aug 4, 2026cs.CV

Dual-domain U-Nets with embedded back projection operators for motion-resolved 4D CBCT reconstruction

Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts. We propose a deep learning method for motion-resolved 4D CBCT reconstruction from conventional free-breathing scans, without a respiratory signal or explicit projection binning. Our CNN takes free-breathing 3D CBCT projections as input and predicts a static volume at maximum inhalation plus ten displacement vector fields (DVFs) spanning a breathing cycle. The network extends U-Net: the encoder acts on filtered projection stacks, the decoder acts in the volume domain, and skip connections are replaced with non-trainable back-projection functions at multiple resolutions to transfer features between domains. The model is trained on simulated CBCT scans and evaluated on 11 unseen simulated patients and 13 clinical free-breathing scans. Two additional models (60 s and 6 s scans) were evaluated by clinical experts on three and two scans, comparing single phases of our 4D reconstruction to reference 3D SART-TV images for tumor and esophagus visibility. Experts preferred our method for tumor visibility (59% vs. 36% no preference, 5% reference) and esophagus visibility (47% vs. 42%, 11%). On simulated data, image quality matched SART-TV (mean RMSE: -1.19 HU, PSNR: +0.09 dB, SSIM: -0.009) while enabling 4D reconstruction. On clinical scans, our method showed sharper dynamic structures (e.g., diaphragm) and fewer motion streak artifacts than traditional reconstruction. This non-patient-specific CNN predicts static volumes and full 4D respiratory motion models from a single free-breathing scan, without a respiratory surrogate or projection binning, reducing motion artifacts while adding motion-modeling capability.
Ivo Herzig, Pascal Paysan, Daniel Barco +8
May 12, 2026cs.CV

BronchoLumen: Analysis of recent YOLO-based architectures for real-time bronchial orifice detection in video bronchoscopy

Bronchoscopy is routinely conducted in pulmonary clinics and intensive care units, but navigating the complex branching of the respiratory tract remains challenging. This paper introduces BronchoLumen, a real-time YOLO-based system for detecting bronchial orifices in video bronchoscopy, aiming to assist navigation and CAD systems. The paper investigates if bronchial orifices can be robustly detected across image domains using state-of-the-art object detection and a limited set of public image data. The study includes the description and comparison of YOLOv8, a widely adopted architecture, and YOLOv12, a more recent architecture integrating attention-based modules to improve spatial reasoning. Both models are trained and tested solely on publicly available datasets comprising different image domains. A comparison of both models is conducted based on the common metrics mAP@0.5 and mAP@0.5:0.9 with the latter emphasizing localization accuracy. For YOLOv8 we obtained a mAP@0.5 of 0.91 on an in-domain and 0.68 on a cross-domain test set. YOLOv12 achieved 0.84 and 0.68 respectively with slightly better localization accuracy with mAP@0.5:0.9 of 0.48 and 0.26 compared to YOLOv8 with 0.45 and 0.25. Challenges like motion blur and low contrast occasionally entailed uncertainties but the system demonstrated overall robustness in most scenarios. BronchoLumen is an open-weight, YOLO-based solution for bronchial orifice detection offering high accuracy and efficiency across multiple image domains. While the more recent YOLOv12 achieves better localization accuracy, we observed a slightly worse precision. The models have been made publicly available to foster further research in bronchoscopy navigation.
Yongchao Li, Marian Himstedt