Organizations: Centre for Artificial Intelligence and Robotics, Hong Kong Institute of Science & Innovation, Chinese Academy of Sciences · Institute of Automation, Chinese Academy of Sciences · The First Affiliated Hospital, Sun Yat-sen University
Camera localization in bronchoscopy remains a challenging problem due to stringent accuracy requirements, real-time constraints, and limited training data. Compared to natural scenes, the confined anatomical structures demand millimeter-level precision, while intraoperative guidance necessitates low-latency inference. However, existing methods often fail to effectively exploit preoperative geometric priors, limiting their robustness and accuracy. To address these limitations, we propose a unified geometry-aware bronchoscope localization framework (GABL) that effectively fuses preoperative structural priors with paired intraoperative video to estimate 6-DoF camera poses. Specifically, to address visual ambiguity in complex airways, we propose a graph-guided coarse-to-fine localization scheme that effectively leverages structural priors for precise pose estimation. Furthermore, to mitigate pose jitter and bridge the visual-structural gap, we integrate a Transformer-based tracking model with a novel RGB-depth matching objective, jointly enforcing spatio-temporal and geometric consistency. Extensive experiments demonstrate that our method yields remarkable reductions of 8.37% and 31.76% in translation and rotation errors over the prior state-of-the-art, alongside 4 times inference speedup (33.6 FPS) for robust real-time bronchoscope localization. Project website: https://paulili08.github.io/GABL/.
Navigational bronchoscopy is critical for pulmonary interventions, yet current platforms depend heavily on pre-operative CT or external sensors, limiting their use in critical care and resource-constrained settings. Vision-only navigation offers a scalable alternative, but conventional visual odometry (VO) struggles with texture-poor airway images, specularities, and the vanishing-point singularities of tubular anatomy, leading to frequent tracking failures and drift. We present a geometry-aware VO framework that explicitly leverages vanishing-point cues from airway lumens. Detected lumens are back-projected to 3D rays, whose weighted fusion yields a stable forward heading even when parallax cues are absent. This heading, together with looming-based velocity estimates, is fused with noisy VO outputs using a bespoke high-gain observer that enforces airway-following priors and rejects drift. We validate the method on ex-vivo mechanically ventilated human lungs with electromagnetic tracking ground truth. Compared to state-of-the-art pipelines (ORB-SLAM2, LoFTR-VO, DPVO), our approach reduces absolute trajectory error by more than 50% and achieves the lowest relative pose error across all test sequences.
Mohammadreza Kasaei, Francis Xiatian Zhang, Feng Li +3
Bronchoscopic navigation relies on registering endoscopic video to a preoperative CT scan, but respiratory motion deforms the airway by 5-20 mm, creating CT-to-body divergence that limits localization accuracy. In practice, this is mitigated through breath-hold protocols, which attempt to match the intraoperative anatomy to a static CT, but are difficult to reproduce and disrupt clinical workflow. We propose to eliminate the need for breath-hold protocols by leveraging patient-specific respiratory modeling. Paired inhale-exhale CT scans, already acquired for planning, implicitly define the patient-specific deformation space of the breathing airway. By registering these scans, we reduce respiratory motion to a single scalar breathing phase per frame, constraining all reconstructions to anatomically observed configurations. We embed this representation within a mesh-anchored Gaussian splatting framework, where a lightweight estimator infers breathing phase directly from endoscopic RGB, enabling continuous, deformation-aware reconstruction throughout the respiratory cycle without breath-holds or external sensing. To enable quantitative evaluation, we introduce RESPIRE, a physically grounded bronchoscopy simulation pipeline with per-frame ground truth for geometry, pose, breathing phase, and deformation. Experiments on RESPIRE show that our approach achieves geometrically faithful reconstruction, over 20x faster training, and 1.22 mm target localization accuracy (within the 3mm clinically relevant tolerances) outperforming unconstrained single-CT baselines. Please check out our website for additional visuals: https://asdunnbe.github.io/RESPIRE/
Bronchoscopy is routinely conducted in pulmonary clinics and intensive care units, but navigating the complex branching of the respiratory tract remains challenging. This paper introduces BronchoLumen, a real-time YOLO-based system for detecting bronchial orifices in video bronchoscopy, aiming to assist navigation and CAD systems. The paper investigates if bronchial orifices can be robustly detected across image domains using state-of-the-art object detection and a limited set of public image data. The study includes the description and comparison of YOLOv8, a widely adopted architecture, and YOLOv12, a more recent architecture integrating attention-based modules to improve spatial reasoning. Both models are trained and tested solely on publicly available datasets comprising different image domains. A comparison of both models is conducted based on the common metrics mAP@0.5 and mAP@0.5:0.9 with the latter emphasizing localization accuracy. For YOLOv8 we obtained a mAP@0.5 of 0.91 on an in-domain and 0.68 on a cross-domain test set. YOLOv12 achieved 0.84 and 0.68 respectively with slightly better localization accuracy with mAP@0.5:0.9 of 0.48 and 0.26 compared to YOLOv8 with 0.45 and 0.25. Challenges like motion blur and low contrast occasionally entailed uncertainties but the system demonstrated overall robustness in most scenarios. BronchoLumen is an open-weight, YOLO-based solution for bronchial orifice detection offering high accuracy and efficiency across multiple image domains. While the more recent YOLOv12 achieves better localization accuracy, we observed a slightly worse precision. The models have been made publicly available to foster further research in bronchoscopy navigation.