Purpose: Laparoscopic ultrasound (LUS) enhances the safety of liver surgery by visualizing intrahepatic vessels in real-time. Still, vessel identification remains difficult due to probe constraints, complex vascular structure, and tissue deformation. This work aims to enable real-time, patient-specific vessel identification that remains robust under deformation through deformable ultrasound augmentation. Methods: Preoperative CT vessel annotations are used to generate synthetic ultrasound data via optimized physics-based rendering, coupled with domain adaptation to intraoperative ultrasound. The rendering is trained end-to-end for vessel identification and patient-specificity, eliminating the need for preoperative ultrasound. A deformation-aware augmentation simulates realistic intraoperative motion and tissue deformation within the rendering pipeline. Results: In abdominal phantom and limited clinical feasibility experiments (single-case clinical evaluation), the framework achieved real-time intrahepatic vessel-branch identification, maintaining performance under new patient poses. Conclusion: The framework enables real-time vessel identification without preoperative ultrasound and supports technical feasibility, but multi-patient validation is still needed for generalizability and clinical feasibility.
Accurate segmentation of hepatic and portal vessels in contrast-enhanced computed tomography angiography (CTA) remains challenging due to complex vascular topology, peripheral visibility limitations, and acquisition-induced ambiguities. While existing public datasets offer valuable benchmarks, few include clinically realistic annotation constraints. We introduce VEELA (Vessel Extraction and Extrication for Liver Analysis), a rigorously curated liver vessel dataset derived from 40 CTA scans inherited from the CHAOS grand-challenge cohort. All vessels were manually delineated slice-by-slice under multi-expert consensus, using a strict visibility-driven annotation policy and avoiding anatomically inferred interpolation. This design explicitly captures anatomical variability and imaging-related uncertainty. As a continuation of the CHAOS challenge, VEELA enables reproducible cross-benchmark evaluation while extending the scope to fine-grained hepatic and portal vessel segmentation. We further establish a standardized benchmarking framework and analyze complementary evaluation metrics, including topology-aware (clDice), overlap-based (IoU), boundary-sensitive (NSD), and geometry-aware (area, length) measures. Our results demonstrate that different metrics capture distinct aspects of vascular integrity, underscoring the necessity of multi-perspective evaluation for clinically meaningful vessel segmentation. VEELA is publicly released to facilitate reproducible research and support the development of robust vascular segmentation methods. Researchers can access the evaluation metrics, dataset, and submission platform at https://www.synapse.org/Synapse:syn65471967.
Blood vessel segmentation is a core task in medical image analysis for the care of vascular diseases and surgical planning, yet the challenges of providing expert vascular annotations pose a major obstacle for the progress of related deep learning techniques. To address this, we propose VesselSim, a two-stage framework for universal 3D blood vessel segmentation that eliminates the need for real annotated data during training. First, we introduce a stochastic, geometry-driven vascular simulation framework that models recursive branching, curvature-controlled growth, and collision-aware topology, followed by domain-randomized intensity synthesis to generate 16,500 anatomically plausible 3D angiographic volumes. Second, a 3D U-Net is trained solely on this synthetic data. To bridge the domain gap from synthetic to real images at inference time, we introduce a test-time adaptation strategy via a self-supervised mask reconstruction decoder, enabling adaptation to unseen clinical scans without prior domain knowledge. We evaluate VesselSim in a zero-shot setting on multiple real-world datasets spanning MR and CT across several anatomical regions, including the brain and kidneys. Despite being trained exclusively on synthetic data, VesselSim achieves performance competitive with state-of-the-art vascular segmentation foundation models. These findings suggest that learning vessel geometry from synthetic tubular structures is effective for robust cross-domain generalization, substantially reducing the reliance on acquired medical imaging data and more importantly, expert annotations.
Large vision-language models (LVLMs) have achieved strong performance across many medical imaging tasks, yet their application to ultrasound remains limited due to its inherent complexity and variability. In this work, we revisit what is truly needed to enable real-world ultrasound understanding. Instead of introducing complex architectures or elaborate training strategies, we show that data scale and clinically faithful data alignment are the key factors. We construct a large-scale dataset of 1.5M real-world ultrasound examinations, containing 17.7M images, multi-organ coverage, and paired uncurated clinical reports. Crucially, we organize the data at the examination level, aligning multiple images with their corresponding reports to reflect real clinical workflows. We then fine-tune a standard LVLM using low-rank adaptation (LoRA) on this dataset without task-specific modifications. Surprisingly, this simple recipe already leads to strong performance across diverse ultrasound understanding tasks, outperforming prior methods designed with more complex pipelines. Beyond these results, we present model and data scaling analyses that provide insights into the role of scale in ultrasound LVLMs.