cs.CVJun 8, 2026

MAGIS: Evidence-Based Multi-Agent Reasoning for Interpretable Strabismus Clinical Decision-Making

Authors: Xikai TangYifan WangJiafan ZhuangLi LuoJinming GuoXiaoling XieJiacheng LiuPeiwei Wei+7 more

Organizations: School of Information and Software Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China · Shenzhen Institute for Advanced Study, University of Electronic Science and Technology of China, Shenzhen, 518000, China · Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, 515041, China · School of Artificial Intelligence, Guangzhou City Polytechnic, Guangzhou, 510405, China · Medical College, Shantou University, Shantou, 515041, China · College of Engineering, Shantou University, Shantou, 515063, China · Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, 200092, China · Shenzhen Loop Area Institute, Shenzhen, 518048, China

Abstract

Strabismus is a common ocular disorder that requires fine-grained subtype diagnosis for individualized treatment planning. However, existing deep learning methods mainly provide diagnostic predictions without transparent reasoning, while recent large vision-language models (LVLMs), although promising for joint image understanding and report generation, remain highly prone to hallucination in this evidence-sensitive and rule-driven medical task. To address these challenges, we propose MAGIS, an evidence-based Multi-AGent reasoning for Interpretable Strabismus diagnosis framework. MAGIS transforms black-box end-to-end generation into a structured diagnostic process consisting of candidate hypothesis generation, dual-evidence constrained context, evidence-based corrective verification, and report generation. Specifically, we introduce a Dual-Evidence Constrained Context (DECC) mechanism that jointly organizes visual evidence from the photograph of the nine cardinal positions of gaze and evidence-based clinical diagnostic rules into a constrained context for reliable diagnostic reasoning. We further develop an Evidence-Based Corrective Verification (EBCV) mechanism that verifies whether the current diagnostic hypothesis is supported by visual evidence, heatmap-based visual cues, and evidence-based clinical diagnostic rules. Hypothesis refinement is triggered when inconsistency is detected. Experiments on a fine-grained strabismus benchmark demonstrate that MAGIS not only significantly outperforms other state-of-the-art diagnostic systems, improving the weighted F1 score from 72.0% to 91.3%, but also substantially improves the clinical reliability (consistency, alignment, and completeness) of generated diagnostic reports. These results demonstrate that MAGIS provides an effective solution for building accurate, evidence-based, and clinically interpretable strabismus diagnosis systems.

Explore similar work

May 7, 2026cs.CV

Retina-RAG: Retrieval-Augmented Vision-Language Modeling for Joint Retinal Diagnosis and Clinical Report Generation

Diabetic Retinopathy (DR) is a leading cause of preventable blindness among working-age adults worldwide, yet most automated screening systems are limited to image-level classification and lack clinically structured reporting. We propose Retina-RAG, a low-cost modular framework that jointly performs DR severity grading, macular edema (ME) detection, and report generation. The architecture decouples a high-performance retinal classifier and a parameter-efficient vision-language model (Qwen2.5-VL-7B-Instruct) adapted via Low-Rank Adaptation (LoRA), enabling flexible component integration. A retrieval-augmented generation (RAG) module injects curated ophthalmic knowledge together with structured classifier outputs at inference time to improve diagnostic consistency and reduce hallucinations. Retina-RAG achieves an F1-score of 0.731 for DR grading and 0.948 for ME detection, substantially outperforming zero-shot Qwen (0.096, 0.732) and MMed-RAG (0.541, 0.641) on a retinal disease detection dataset with captions. For report generation, Retina-RAG attains ROUGE-L 0.438 and SBERT similarity 0.884, exceeding all baselines. The full framework operates on a single consumer-grade GPU, demonstrating that clinically structured retinal AI can be achieved with modest computational resources.
Abdelrahman Zaian, Sheethal Bhat, Mohamed Abdalkader +1
Aug 10, 2025cs.AI

EndoCogniAgent: Closed-Loop Agentic Reasoning with Self-Consistency Validation for Endoscopic Diagnosis

Endoscopic diagnosis is an iterative process in which clinicians acquire, compare, and verify local visual evidence before reaching a conclusion. Current AI systems do not adequately support this process because fine-grained evidence acquisition and multi-step reasoning remain weakly coupled, complicating reconciliation of image-derived findings with their textual interpretations. This gives rise to two failure modes, hallucinated evidence and uncorrected error accumulation, that undermine diagnostic reliability. We propose EndoCogniAgent, a closed-loop agentic framework that formulates endoscopic diagnosis as a controlled state update process for integrating complementary visual and textual evidence. At each reasoning round, a central planner selects an evidence acquisition action, specialized expert tools extract spatial and semantic observations as structured textual evidence, and a self-consistency validation mechanism examines this evidence along two dimensions, knowledge consistency against the input image and temporal consistency with prior validated findings, before updating the diagnostic state. Validated observations are admitted into the evolving state to condition subsequent planning, while insufficiently supported or conflicting findings are retained with corrective feedback that redirects the planner toward additional verification. We further introduce EndoAgentBench, a workflow-oriented benchmark comprising 6,132 question-answer pairs from 11 endoscopic datasets, to evaluate diagnostic agents across a comprehensive diagnostic chain, from fine-grained visual perception to high-level diagnostic reasoning. EndoCogniAgent achieves 85.23% overall accuracy on perception tasks and 71.13% clinical acceptance rate on reasoning tasks. Blinded clinician evaluation further shows consistent improvements in diagnostic response quality over the evaluated baselines.
Yi Tang, Kai-Ni Wang, Liang-Peng Pu +3
Mar 23, 2026cs.AI

Guideline-grounded retrieval-augmented generation for ophthalmic clinical decision support

In this work, we propose Oph-Guid-RAG, a multimodal visual RAG system for ophthalmology clinical question answering and decision support. We treat each guideline page as an independent evidence unit and directly retrieve page images, preserving tables, flowcharts, and layout information. We further design a controllable retrieval framework with routing and filtering, which selectively introduces external evidence and reduces noise. The system integrates query decomposition, query rewriting, retrieval, reranking, and multimodal reasoning, and provides traceable outputs with guideline page references. We evaluate our method on HealthBench using a doctor-based scoring protocol. On the hard subset, our approach improves the overall score from 0.2969 to 0.3861 (+0.0892, +30.0%) compared to GPT-5.2, and achieves higher accuracy, improving from 0.5956 to 0.6576 (+0.0620, +10.4%). Compared to GPT-5.4, our method achieves a larger accuracy gain of +0.1289 (+24.4%). These results show that our method is more effective on challenging cases that require precise, evidence-based reasoning. Ablation studies further show that reranking, routing, and retrieval design are critical for stable performance, especially under difficult settings. Overall, we show how combining visionbased retrieval with controllable reasoning can improve evidence grounding and robustness in clinical AI applications,while pointing out that further work is needed to be more complete.
Shuying Chen, Sen Cui, Zhong Cao