cs.CVJun 19, 2026

NoduLoCC2026: Lung Nodule Localization and Classification Contest from Chest X-Ray Images

Authors: Adnan MustaficHalim BenhabilesAdnane CabaniKristhian André Oliveira AguilarRomain AmigonClément BardinChiara BentifeceMarin Boehm+14 more

Abstract

We propose NoduLoCC2026, a challenge on lung nodule detection and localization in chest X-ray images. We have provided a dataset for both tasks and received submissions from 5 international teams. The participating teams' solutions are presented in this work along with results on an external dataset used for testing. Proposed methods show good performance on the classification task. The best method shows a balanced accuracy score of 0.72 and AUC-ROC of 0.79. We highlight the limitations of current approaches for the localization task, with the best approach having predicted the correct number of nodules on 53% of the test images with a median distance of 12.83mm, showing that it is a more challenging task than the first one. The challenge website is available via https://gt-i2mdp.github.io/website/nodule_challenge.html.

Explore similar work

Sep 12, 2026cs.CV

GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT

Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.
Haojie Yang, Ran Su
Apr 16, 2026cs.CV

CXR-LT 2026 Challenge: Multi-Center Long-Tailed and Zero Shot Chest X-ray Classification

Chest X-ray (CXR) interpretation is hindered by the long-tailed distribution of pathologies and the open-world nature of clinical environments. Existing benchmarks often rely on closed-set classes from a single institution, failing to capture the prevalence of rare diseases or the appearance of novel findings. To address this, we present the CXR-LT challenge. The first event, CXR-LT 2023, established a large-scale benchmark for long-tailed multi-label CXR classification and identified key challenges in rare disease recognition. CXR-LT 2024 further expanded the label space and introduced a zero-shot task to study generalization to unseen findings. Building on the success of CXR-LT 2023 and 2024, this third iteration of the benchmark introduces a multi-center dataset comprising over 145,000 images from PadChest and NIH Chest X-ray datasets. Additionally, all development and test sets in CXR-LT 2026 are annotated by radiologists, providing a more reliable and clinically grounded evaluation than report-derived labels. The challenge defines two core tasks this year: (1) Robust Multi-Label Classification on 30 known classes and (2) Open-World Generalization to 6 unseen (out-of-distribution) rare disease classes. This paper summarizes the overview of the CXR-LT 2026 challenge. We describe the data collection and annotation procedures, analyze solution strategies adopted by participating teams, and evaluate head-versus-tail performance, calibration, and cross-center generalization gaps. Our results show that vision-language foundation models improve both in-distribution and zero-shot performance, but detecting rare findings under multi-center shift remains challenging. Our study provides a foundation for developing and evaluating AI systems in realistic long-tailed and open-world clinical conditions.
Hexin Dong, Yi Lin, Pengyu Zhou +25
Jul 10, 2026cs.CV

From Classification to Localization and Clinical Validation: Large-Scale Development of a Deep Learning System for Thoracic Disease Detection on Chest Radiographs in Thailand

Chest radiography (CXR) remains the most widely used thoracic imaging modality, yet expert interpretation is constrained by a severe shortage of radiologists in Thailand and across Southeast Asia. Local adaptation of deep learning models to Thai data has been shown to substantially improve accuracy on Thai populations. Here we present the development and comprehensive validation of the chest radiograph analysis model in Inspectra CXR version 5, a deep learning system that performs multi-label thoracic disease classification and weakly supervised lesion localization within a single model. The architecture couples a DenseNet-121 backbone with Attend-and-Compare Modules (ACM) and a Probabilistic Class Activation Map (PCAM) aggregation layer, producing a per-condition classification score and heatmap simultaneously. The model was developed on 874,858 frontal chest radiographs with paired radiologist reports from Siriraj Hospital, Bangkok. On a held-out, radiologist-verified in-domain test set of 19,871 cases, it achieved a mean AUROC of 0.994 (mean sensitivity 92.4%, specificity 98.6%) across nine clinically important conditions. On an independent generalization set of 5,992 cases from 13 hospitals across Thailand, the mean AUROC was 0.970, indicating robust transfer across sites. For localization, evaluated on 4,549 radiologist-annotated cases, the model attained a mean lesion-localization fraction (LLF) of 77.9% at 0.59 non-lesion localizations per image. In a usability evaluation with five thoracic radiologists, the system reached a classification concordance of 93.6%, a localization concordance of 94.7%, and a mean System Usability Scale (SUS) score of 89. These results indicate that a locally developed, localization-capable CXR system can deliver high accuracy, generalize across heterogeneous Thai hospitals, and earn the trust of practicing radiologists.
Isarun Chamveha, Tretap Promwiset, Napat Wanchaitanawong +3