eess.IVJun 23, 2026

Female-RHINO: A Real-Time Scanner-Integrated Framework for Automated Quantitative Uterine MRI Analysis and Structured Reporting

Authors: Deepak BhatiaSaad AhmadSmiti TripathyMaria Camila Bustos VivasLieselotte KratzschAnika KnupferJordina Aviles VerderaSusanne Schulz-Heise+2 more

Abstract

Standardized assessment of uterine MRI remains challenging due to anatomical variability, observer dependence, and the lack of workflow-integrated automated analysis tools. This work presents Female-RHINO: (R)eproductive (H)ealth (I)maging A(N)alysis T(O)ol, a real-time AI-assisted framework for automated quantitative uterine MRI analysis and structured reporting during image acquisition. We present an end-to-end system that integrates inline communication with the MRI scanner and deep learning-based analysis to derive quantitative uterine biomarkers from sagittal T2-weighted pelvic MRI. The framework combines segmentation and anatomical landmark detection models trained and evaluated on more than 500 multi-center datasets spanning diverse protocols, vendors, and patient populations. It performs volumetry, detects and quantifies common incidental findings such as fibroids and Nabothian cysts, and extracts six anatomical landmarks for biometric assessment. Results are compiled into a structured clinician-oriented report with integrated visualizations, without manual interaction. Evaluation on independent retrospective and prospective cohorts demonstrated robust performance across varying acquisition settings. Mean Dice similarity coefficients were 0.82 for the uterus and 0.80 for fibroids, with lower but consistent agreement for Nabothian cysts. Landmark detection achieved a mean radial error of 3.7 mm. End-to-end processing was completed in under 70 seconds, enabling availability of results during the ongoing scan. Prospective deployment yielded immediate, standardized, and reproducible analyses supported by inter-observer agreement. The proposed system enables real-time scanner-integrated AI for automated uterine MRI analysis and reporting, with potential to improve standardization, efficiency, and clinical workflow in pelvic imaging.

Explore similar work

Jul 27, 2026cs.CV

Panda: Unsupervised Pelvic Anomaly Detection for Real-Time MR Imaging

Female pelvic diseases remain an under researched area characterized by often delayed diagnosis. While pelvic MRI offers superior soft-tissue contrast for diagnosis and image-guided procedures, real-time anomaly detection remains challenging due to physiological motion, tissue deformation, and instrument artifacts. Existing supervised approaches are impractical, as adverse events are rare, heterogeneous, and difficult to annotate. We present a Dinomaly-based unsupervised anomaly detection framework adapted for pelvic MRI that learns normative representations from healthy cases and flags deviations without requiring labels. Our approach leverages a frozen DINOv3 Vision Transformer encoder combined with a noisy MLP bottleneck and Linear Attention decoder to prevent identity mapping while maintaining computational efficiency. Anomalies are localized via per-token cosine distance between encoder and decoder representations, yielding spatial anomaly maps that provide immediate feedback at the scanner to support radiologist decision-making and adaptive protocol adjustment. Evaluated on a curated subset of the Uterine Myoma Dataset, the framework achieves a pixel-level AUROC of 88.06% and high specificity (95.45%) at frame level at 40.5 slices/s, meeting real-time clinical deployment requirements. The spatial anomaly maps and frame-level scores provide immediate, localized feedback at the scanner to support radiologist decision-making and adaptive protocol adjustment during active procedures.
Anika Knupfer, Maximilian Lindholz, Johanna Paula Müller +4
May 23, 2026physics.med-ph

Catching magnetic resonance imaging outliers in artificial intelligence-supported radiotherapy workflows: unsupervised detection and localization of image anomalies using deep learning

Artificial intelligence is increasingly integrated into radiotherapy workflows, yet such pipelines remain vulnerable to out-of-distribution image data that may introduce unexpected behavior in clinical tasks. Deep learning-based anomaly detection for pelvic magnetic resonance imaging (MRI) remains largely unexplored, and transparent evaluation of its feasibility for full automation is limited. We developed and evaluated a fully automated, unsupervised anomaly-detection framework for pelvic and brain MRI. A two-stage framework was trained on reference images from public datasets: LUND-PROBE for pelvic MRI, and IXI, fastMRI, and fastMRI+ for brain MRI. In the first stage, MRI slices were compressed into discrete tokens; in the second, the distribution of normal tokens was modeled. Anomaly evidence was estimated by combining perceptual image differences with token-surprisal scores based on negative log-likelihood. Automated detection was evaluated on pelvic MRI with synthetic global and real clinical anomalies, and on brain MRI with clinically annotated fastMRI+ abnormalities. Sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and false-positive behavior in held-out normal cases were assessed. The framework achieved robust detection across hidden evaluation cohorts, with AUCs of 0.97 (95% CI, 0.95-0.98) and 0.81 (95% CI, 0.74-0.87) for pelvic and brain MRI, respectively. Heatmap analysis showed strong spatial agreement between detected anomalies and ground-truth locations, supporting localization accuracy and interpretability. These results support the potential of unsupervised anomaly detection as an automated MRI quality-control layer for radiotherapy workflows, with transparent visualization of image regions likely to compromise downstream AI-based tasks.
Mustafa Kadhim, Viktor Rogowski, Emilia Persson +7
Jun 17, 2026cs.HC

A Clinician-Centered Pipeline for Annotation and Evaluation in Ultrasound AI Studies

Clinician-centered evaluation is critical for validating medical AI systems, especially in ultrasound imaging where quantitative metrics do not always capture clinical usability. Existing medical image platforms primarily focus on dataset labeling. They lack integrated support for blinded model comparison and reproducible evaluation workflows. We present a clinician-centered pipeline for remote annotation and evaluation in ultrasound AI studies. The proposed pipeline uses a centralized server and lightweight browser interfaces to enable clinicians to perform annotation, blinded ranking, and review without local dataset downloads. The pipeline also supports multi-rater participation, centralized result aggregation, and automated statistical analysis. We validate the pipeline in a fetal ultrasound segmentation study with six raters spanning expert, generalist, and non-expert experience levels. The system automatically generated Spearman correlation, Kendall's ττ, and top-1 selection statistics. Results indicated moderate to strong agreement across experts and other groups. The blinded evaluation results showed a tendency for later active learning models to be preferred. These outcomes suggest that the pipeline can support clinician-centered annotation and reproducible human-\ac{AI} evaluation studies in ultrasound imaging. The proposed pipeline is available on \href{https://github.com/13204942/SonoRate}{GitHub}.
Fangyijie Wang, Jianjun Yu, Wentao Shi +4