cs.CVJun 25, 2026

Anatomy-Guided Residual Motion Diffusion for Controllable 4D Cardiac MRI Synthesis

Authors: Yiheng CaoGustavo Andrade-MirandaJiatian ZhangLingxiao ZhaoXin Gao

Organizations: Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, China · Systemes Complexes et Intelligence Artificielle, IMT Mines Ales, Ales, France · School of Artificial Intelligence and Advanced Computing, Xi’an Jiaotong-Liverpool University, Suzhou, China

Abstract

Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation. A semi-supervised variational autoencoder learns a compact latent representation of anatomical volumes while jointly predicting aligned segmentation masks in a unified framework. Anatomical structure is then disentangled from temporal dynamics through a cascaded latent diffusion model (LDM). A static LDM generates subject-specific anatomy conditioned on clinical priors (diagnosis and volumes measures) and a subsequent motion LDM estimates residual latent motions, ensuring strict temporal coherence across the 4D sequence. The proposed approach was evaluated on cine cardiac MRI as a representative 4D imaging application. Experiments across multiple datasets demonstrate high controllability of static anatomy (Pearson r > 0.8) and strong temporal coherence (FVD = 288.08). In cross-vendor generalization experiments, augmenting training sets with synthetic 4D sequences significantly improves downstream segmentation performance. Using nnU-Net, the proposed augmentation strategy improves the average Dice score by 1.4% and reduces the Hausdorff Distance by 3.0mm compared to training on real data alone, for the left ventricle, Dice improves by 2.8% with a 5.4mm reduction in boundary error. Overall, this framework provides a scalable and controllable solution for 4D medical image synthesis, supporting the development of more robust models with limited annotations and cross-vendor variability. Code available on https://github.com/cyiheng/4DCardiacMRISynthesis.

Explore similar work

Jun 8, 2026cs.CV

Temporally Consistent and Controllable Video Generation of 2D Cine CMR via Latent Space Motion Modeling

Cine cardiac magnetic resonance is the gold standard for assessing cardiac function, but the scarcity of public datasets limits the development of advanced data-driven models. To address this limitation, we propose a generative method for synthesizing temporally coherent and anatomically consistent cardiac sequences. Our text-to-video framework decouples cardiac spatial structure from temporal motion. First, a fine-tuned diffusion model synthesizes an initial frame from a clinical text prompt, controlling anatomical features. Then, a latent flow model conditioned on a cardiac phase embedding generates the complete cardiac motion, ensuring spatial consistency and temporal control. Our model generates anatomically and pathologically diverse sequences with high temporal coherence and strong fidelity to input prompts, achieving a FID of 31.68 for image realism and a CLIP score of 31.04 for text-image alignment. These experimental results highlight its potential to produce high-fidelity, on-demand medical data, offering a scalable solution to data scarcity.
Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang +2
Jun 2, 2026cs.CV

Conditional Latent Diffusion Model with Fourier-based Motion Modelling for Virtual Population Synthesis

In-silico trials of medical devices require the generation of virtual populations of anatomies. In cardiovascular applications, virtual anatomy is typically represented as a 3D+t mesh sampled from a generative model. However, most existing mesh generators focus on static anatomy, while sequence models often lack explicit periodicity. To this end, we propose 4D F-MeshLDM, a conditional generative framework comprising a convolutional mesh VAE to encode meshes, a structural latent space that parameterises motion using a truncated Fourier series, and a diffusion prior that learns the latent distribution over Fourier coefficient tokens. By conditioning the diffusion process on clinical covariates via affine modulation, we enable controllable synthesis. Sampling tokens and performing inverse Fourier synthesis yield cycle-consistent latent trajectories, which can be decoded into 3D+t cardiac mesh sequences. Experiments on 5,000 UK Biobank subjects demonstrate that 4D F-MeshLDM outperforms state-of-the-art baselines in anatomical fidelity and achieves near-zero cycle closure error. Furthermore, the generated cohorts accurately preserve clinical functional indices, highlighting the potential of our framework for reliable in-silico cardiac trials.
Shaokun Lan, Haoran Dou, Jinghan Huang +5
Jul 2, 2026cs.CV

Personalized 4D Whole-Heart Mesh Reconstruction from Cine MRI via Multi-Scale Temporal Modeling and Differentiable Contour Rendering

Accurate 4D whole-heart mesh reconstruction from sparse cine MRI is critical for creating cardiac digital twins, but remains challenging due to limited 2D slice coverage and the complex coupling between cardiac shape and motion. Existing methods often rely on intermediate contour fitting and typically reconstruct static, single-phase, or partial cardiac geometries, limiting their ability to capture full-chamber dynamics. We propose a novel end-to-end framework for reconstructing temporally resolved whole-heart meshes from multi-view 2D cine MRI sequences by learning an image-to-mesh mapping. The framework incorporates a differentiable contour renderer inspired by the Beer-Lambert attenuation principle, enabling anatomy-aware supervision of 3D+t mesh deformation through contour-based projection losses. To improve temporal consistency across the cardiac cycle, we further introduce a multi-scale temporal modeling module that integrates global cycle-level dynamics with local inter-frame coherence to generate smooth and physiologically plausible mesh trajectories. The proposed method achieved a whole-heart mean absolute error of 1.68 ±\pm 0.31 mm and a motion jitter of 0.77 ±\pm 0.17 mm/frame3\mathrm{mm}/\mathrm{frame}^{3}, outperforming existing methods with lower reconstruction error and substantially improved motion smoothness. It also improved 2D contour alignment across multiple cine MRI views and supported downstream proof-of-concept electrophysiological simulation. The code will be released publicly upon acceptance of the manuscript for publication.
Xiaoyue Liu, Dongcheng Cang, Xiaohan Yuan +3