Predicting a patient's physiological trajectory under a planned treatment sequence is a prospective interventional problem, not standard time-series extrapolation. We study this problem in glucose management, where insulin and carbohydrate records are policy-dependent: future drivers are coupled to patient state, behavior, and clinical decision rules, so observational forecasting accuracy alone does not guarantee correct responses to planned interventions. We introduce Interventional Flow Matching (IFM), a continuous-time generative framework for physiologically constrained prospective forecasting. IFM conditions a flow-matching velocity field on patient history and planned future drivers in a bounded latent glucose space. Rather than embedding strict mechanistic glucose--insulin ODE equations or enforcing causality through rollout-based simulations, IFM uses a solver-free regularization: it penalizes the Jacobian of the instantaneous velocity field with respect to smoothed treatment drivers. This imposes signed, dose-bounded local sensitivities directly on the learned dynamics: insulin lowers glucose, carbohydrates raise it, and both responses remain within plausible ranges. On a simulated UVA/Padova type 1 diabetes cohort, IFM achieves the strongest balance between observed-driver RMSE and interventional response metrics. Across experiments, it consistently produces physiologically correct responses to both insulin and carbohydrate drivers while maintaining high directional, and ranking consistency.
Clinical time-series forecasting is increasingly studied for decision support, yet standard aggregate metrics can obscure whether a model is actually useful for the task it is meant to serve. In safety-critical settings, low average error can coexist with dangerous failures in exactly the high-risk regimes that matter most. We present a task-aware evaluation framework for blood glucose forecasting built around two downstream uses: hypoglycemia early warning and insulin dosing decision support. For early warning, we evaluate on real data from three clinical cohorts using event-level recall and false alarms per patient-day, metrics that reflect operational alarm burden rather than aggregate accuracy. We show that models appearing acceptable overall, with recall above 0.9 on the full test set, can fail badly in the post-bolus slice, where insulin-on-board is elevated and missed warnings carry the greatest clinical consequences. Standard forecasting evaluation, however, does not test whether a model can reason about the effects of actions, a requirement for supporting insulin dosing decisions. We therefore add a second, interventional arm using the FDA-accepted UVA/Padova simulator, where we evaluate whether forecasters can predict glucose responses to altered insulin plans in paired factual/counterfactual scenarios. We show that models that look strong on real-data forecasting often fail to predict the direction, magnitude, or ranking of intervention effects, and choose poor insulin doses when evaluated under a clinically motivated cost. Taken together, the two arms reveal a consistent gap between forecasting accuracy and task-relevant usefulness. We release the benchmark, the standardized preprocessing pipeline for public cohorts, and the simulator-based interventional dataset as a reproducible toolkit.
Accurate long-horizon glucose forecasting is critical for automated insulin delivery systems, which help people with type 1 diabetes (T1D) manage their glucose and avoid dangerous hypoglycemia. However, standard recursive long short-term memory (LSTM) networks suffer from systematic negative bias at longer horizons due to error compounding, while purely mechanistic ordinary differential equation (ODE) models fail to generalize across individuals when parameterized at the population level. We propose PhysioSeq2Seq, a hybrid architecture that combines patient-specific physiological modeling with a sequence-to-sequence (Seq2Seq) LSTM. For each glucose segment, twin matching searches a population of 300 parameterized digital twins to identify the best-fitting physiological match from a 3-hour continuous glucose monitoring (CGM) history. The 10 internal ODE state variables of the matched twin are injected as exogenous covariates into both the encoder and decoder of the Seq2Seq LSTM. This simultaneous 48-step prediction strategy eliminates recursive error compounding, while the ODE features provide a physics-grounded constraint that bounds long-horizon drift within physiologically plausible ranges. PhysioSeq2Seq was trained on CGM and insulin data from 348 participants in the Type 1 Diabetes Exercise Initiative (T1DEXI) dataset and evaluated on 74 held-out participants. At the 240-minute horizon, PhysioSeq2Seq achieves a mean absolute error of 39.28 mg/dL and a mean error of -10.62 mg/dL, reducing bias by 13.89 mg/dL over the recursive LSTM and reducing mean absolute error by 28.62 mg/dL over the ODE-based digital twin. These results show that eliminating architectural feedback and injecting patient-matched physiological states is an effective and clinically meaningful strategy for long-horizon glucose forecasting in T1D.
We introduce Prior-Fitted Functional Flows, a generative foundation model for pharmacokinetics that enables zero-shot population synthesis and individual forecasting without manual parameter tuning. We learn functional vector fields, explicitly conditioned on the sparse, irregular data of an entire study population. This enables the generation of coherent virtual cohorts as well as forecasting of partially observed patient trajectories with calibrated uncertainty. We construct a new open-access literature corpus to inform our priors, and demonstrate state-of-the-art predictive accuracy on extensive real-world datasets.