Accelerated magnetic resonance imaging reduces acquisition time, but reconstruction from undersampled k-space can blur diagnostically relevant structures or introduce failures that are not captured by global image metrics. We propose SA-RDM-DC, a Self-Auditing Residual generative Drifting Model with Data Consistency for accelerated knee MRI. The method adapts the newly proposed generative drifting paradigm to accelerated MRI by training a physics-conditioned drift field from the zero-filled reconstruction toward the fully sampled residual correction. It predicts image- and missing-k-space residual corrections, enforces data consistency with acquired k-space, uses frequency-aware and residual drifting supervision to recover fine detail, and produces dense error maps and slice-level risk scores in the same inference pass. We evaluate SA-RDM-DC on multi-coil fastMRI knee data at acceleration factors of 4, 8, and 12, with fastMRI+ pathology annotations for region-level and classifier-based task preservation, and on SKM-TEA for zero-shot and fine-tuned protocol-shift evaluation. Compared with zero-filled reconstruction, UNet-image-SENSE, DC-UNet, Score-Diffusion, ELF-Diff, SENSE-VarNet, and MoDL baselines, SA-RDM-DC achieves the highest SSIM across fastMRI acceleration factors while retaining subsecond per-slice inference and avoiding the long sampling time of iterative diffusion baselines. In pathology-aware analysis, SA-RDM-DC preserves lesion-region structural fidelity and reduces meniscus prediction instability. Its self-auditing scores strongly identify high-error reconstructions on fastMRI and partially transfer as a selective-review signal under SKM-TEA protocol shift. These results support reconstruction evaluation that jointly considers image fidelity, pathology preservation, runtime, and case-specific reliability.
MRI reconstruction is an inherently ill-posed inverse problem, since incomplete measurements admit many plausible solutions. This ambiguity becomes more severe under high acceleration, where pixel-domain continuous predictors tend to average over feasible reconstructions and suppress high-frequency anatomy. We address this limitation by moving reconstruction to discrete multi-scale latent space and posing it as autoregressive next-acceleration-scale prediction. Leveraging discrete priors proven effective in visual autoregressive modeling, our method restricts the solution to compact sequences of codebook tokens, enabling sharp reconstructions even from extremely sparse measurements. This discrete autoregressive formulation also aligns naturally with modern large language model post-training techniques. Building on this observation, we introduce on-policy privileged information distillation for visual autoregressive modeling, where a teacher is provided training only privileged context that is unavailable at inference, in our case fully sampled acquisitions, and supervises a student trained on its own rollouts, leading to consistent reconstruction gains. Through extensive experiments on the fastMRI benchmark, we show that our approach delivers improved reconstruction performance across diverse sampling patterns under extreme undersampling. Project website is \href{https://yilmazkorkmaz1.github.io/discrete-mri-reconstruction-opd/}{here}.
Accelerated magnetic resonance imaging (MRI) enabled by the training of deep learning (DL)-based image recon. models requires large and diverse raw k-space datasets. In most clinical MRI applications, due to storage and patient privacy concerns, raw k-space data is discarded and magnitude-only images are the only component saved. Consequently, a large portion of the DL-based MRI recon. literature has either relied on small training datasets or has used one of the few available open-source k-space datasets. At the same time, the growing number of anonymized magnitude-only image registries/databases motivates the development of techniques that can use them as training datasets for generalizable DL-based recon. models. Here we propose to address this challenge by employing a generative approach based on conditional score-based diffusion models (SBDMs): given a magnitude-only MR image, it synthesizes a phase map (in the image domain) that realistically corresponds to the magnitude-only image. We evaluate its generative capabilities in a downstream DL-based recon. task whereby a large k-space dataset is generated by combining the SBDM-synthesized phase-maps and the corresponding magnitude-only images, and this k-space dataset is then used to train a DL model for accelerated MRI recon. We compare the performance of the resulting DL model versus those trained according to (a) a naive approach that uses smooth phase, (b) a k-space training dataset generated using synthesized phase maps derived from a generative adversarial network, and (c) the ground truth k-space data. Our results suggest that the DL model trained from SBDM-synthesized k-space data outperforms the other approaches in terms of quantitative metrics as well as qualitatively observed recon. fidelity, i.e., whether the reconstructed images include erroneous or hallucinated features that could adversely impact diagnostic accuracy.
M. Berk Sahin, Dilek Yalcinkaya, Abolfazl Hashemi +1
Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixel-wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.
Ilias I. Giannakopoulos, Lokesh B Gautham Muthukumar, Yvonne W. Lui +1