Cardiac MRI Through-Plane Super-Resolution Guided by Reference and Memory
Authors: Shaoming Pan, Chenchuhui Hu, Leon Axel, Meng Ye
Organizations: University of Texas at Arlington · New York University Grossman School of Medicine
Abstract
Clinical cardiac MRI is commonly acquired with high in-plane resolution but coarse through-plane resolution to reduce scan time and accommodate breath-hold and cardiac-motion constraints, which limits 3D analysis and diagnostic accuracy. We propose STRMSR, a reference- and memory-guided through-plane super-resolution (SR) framework that reconstructs high-resolution (HR) cardiac volumes by leveraging HR reference views acquired from the same subject and intermediate SR results as the memory. Our method uses coarse-to-fine contextual matching to establish robust correspondence between low-resolution target and reference/memory images under spatial misalignment. A learnable patch-wise dynamic feature aggregation module predicts content-adaptive mixture weights for each local patch, effectively fusing dynamic information while suppressing unreliable feature transfers. The intermediate SR results stored in the memory bank ensure slice-to-slice consistency for the super-resolved 3D volume. Experiments on the WHS cardiac MRI dataset under two reference protocols, orthogonal-plane views and long-axis chamber views, demonstrate consistent improvements over baselines at 4x and 8x upsampling factors.
Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.
Accurate 4D whole-heart mesh reconstruction from sparse cine MRI is critical for creating cardiac digital twins, but remains challenging due to limited 2D slice coverage and the complex coupling between cardiac shape and motion. Existing methods often rely on intermediate contour fitting and typically reconstruct static, single-phase, or partial cardiac geometries, limiting their ability to capture full-chamber dynamics. We propose a novel end-to-end framework for reconstructing temporally resolved whole-heart meshes from multi-view 2D cine MRI sequences by learning an image-to-mesh mapping. The framework incorporates a differentiable contour renderer inspired by the Beer-Lambert attenuation principle, enabling anatomy-aware supervision of 3D+t mesh deformation through contour-based projection losses. To improve temporal consistency across the cardiac cycle, we further introduce a multi-scale temporal modeling module that integrates global cycle-level dynamics with local inter-frame coherence to generate smooth and physiologically plausible mesh trajectories. The proposed method achieved a whole-heart mean absolute error of 1.68 ± 0.31 mm and a motion jitter of 0.77 ± 0.17 mm/frame3, outperforming existing methods with lower reconstruction error and substantially improved motion smoothness. It also improved 2D contour alignment across multiple cine MRI views and supported downstream proof-of-concept electrophysiological simulation. The code will be released publicly upon acceptance of the manuscript for publication.
Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.
Yihong Chen, Jiancheng Yang, Deniz Sayin Mercadier +3