cs.ROJul 8, 2026

In vivo feasibility study of humanoid robots in surgery

Authors: Zekai LiangNikita TharejaPeihan ZhangCalvin JoyceSoofiyan AtarFlorian RichterGarth JacobsenShanglei Liu+2 more

Abstract

Recent advances in actuation, control and learning have rapidly pushed humanoid robots from a distant vision towards near-term real-world deployment. Healthcare is a particularly pressing domain, in which staffing shortages and increasing care demand are widening the gap between clinical workload and available skilled labour. Although current automation has largely focused on digital and logistical tasks, much hospital work remains embodied, requiring mobility, manipulation and safe interaction in human-designed environments. Humanoid form factors offer unique potential, particularly for assisting with surgical tasks. Traditionally, robotic systems for surgery are purpose-built platforms such as Intuitive Surgical's da Vinci Surgical System, and it remains unclear how close current humanoid systems are to meeting the precision, control and safety requirements of minimally invasive surgery. Here we present a systematic evaluation of contemporary humanoid technology for laparoscopic surgical tasks. We develop a humanoid-based laparoscopic teleoperation framework using general-purpose instruments and assess its abilities through benchtop characterization, dry-laboratory user studies spanning diverse surgical experience levels and in vivo porcine studies. Across these evaluations, we quantify technical feasibility, task performance and clinical readiness relative to established surgical platforms. Together, our study provides an evidence-based assessment of current humanoid abilities and limitations for surgical applications, highlighting both their promise and key technical challenges that must be addressed before clinical deployment.

Explore similar work

Oct 3, 2025cs.RO

LapSurgie: Humanoid Robots Performing Surgery via Teleoperated Handheld Laparoscopy

Robotic laparoscopic surgery has gained increasing attention in recent years for its potential to deliver more efficient and precise minimally invasive procedures. However, adoption of surgical robotic platforms remains largely confined to high-resource medical centers, exacerbating healthcare disparities in rural and low-resource regions. To close this gap, a range of solutions has been explored, from remote mentorship to fully remote telesurgery. Yet, the practical deployment of surgical robotic systems to underserved communities remains an unsolved challenge. Humanoid systems offer a promising path toward deployability, as they can directly operate in environments designed for humans without extensive infrastructure modifications -- including operating rooms. In this work, we introduce LapSurgie, the first humanoid-robot-based laparoscopic teleoperation framework. The system leverages an inverse-mapping strategy for manual-wristed laparoscopic instruments that abides to remote center-of-motion constraints, enabling precise hand-to-tool control of off-the-shelf surgical laparoscopic tools without additional setup requirements. A control console equipped with a stereo vision system provides real-time visual feedback. Finally, a comprehensive user study across platforms demonstrates the effectiveness of the proposed framework and provides initial evidence for the feasibility of deploying humanoid robots in laparoscopic procedures.
Zekai Liang, Xiao Liang, Soofiyan Atar +7
Apr 30, 2026cs.RO

An Experimental Modular Instrument With a Haptic Feedback Framework for Robotic Surgery Training

Robotic-assisted surgery offers significant clinical advantages but largely eliminates direct haptic feedback, increasing the risk of excessive tool-tissue interaction forces. Although recent commercial systems have begun to introduce force feedback, their high cost limits accessibility, particularly for surgical training. This paper presents a modular experimental robotic laparoscopic instrument integrated with a real-time haptic feedback framework. The proposed instrument employs a wrist-mounted force/torque (F/T) sensor to estimate tool-tissue interaction forces while avoiding the durability and integration challenges of tip-mounted sensors. A haptic feedback framework is developed to extract the external contact forces, render them to the haptic device, and generate stable and perceptually meaningful feedback. The instrument is integrated into the robotic surgery training system (RoboScope) and evaluated through a controlled user study involving a force regulation task. Experimental results demonstrate that haptic feedback significantly improves task success rate, force regulation accuracy, and task efficiency compared to visual-only feedback. The proposed instrument enables stable, high-fidelity haptic interaction, supporting effective robotic surgery training.
Walid Shaker, Mustafa Suphi Erden
Sep 22, 2026cs.RO

Contact-Stable Deformable Tissue Simulation Using Implicit Integration and Live-Pose Grasp Constraints for Laparoscopic Surgery Robot Policy Evaluation

Closed-loop evaluation of surgical robots requires tissue that deforms, can be grasped and lifted, and reproduces the anatomy in which the robot will operate. We present a simulator in which this tissue is reconstructed from a fixed-view RGB-D recording of the surgical field, composited to remove the instruments, closed into watertight volumes and tetrahedralised; the pipeline was applied unchanged to three specimens of two species (thirteen organs, 146,061 tetrahedra, no inverted elements). For one specimen, the organs are placed in a bimanual cell in which two Franka FR3 arms operate motorised instruments through 6 mm trocars. The core contribution is the numerical and contact design that keeps this cell stable: implicit integration, simulation meshes separate from collision meshes, numerical guards, and a grasp constraint captured at the live tissue pose. In 45 repeated grasp-lifts, a friction grasp held the tissue in 0 of 15 trials and each constraint grasp in 13 of 15; on displaced tissue, a rest-pose constraint produced one-step snaps of up to 17.8 mm, which live-pose capture eliminates. Against the recording, front-surface depth error is 1.33 to 1.41 mm, organ silhouette IoU is 0.80, and in five grasp-lifts reproduced from video the landmark displacement RMSE is 11.8 mm against 14.2 mm for a static prediction. Biofidelity is not claimed; the environment is intended for closed-loop feasibility, safety, contact and policy screening.
Juahn Oh, Dongho Yee, Jinseok Lee +9