eess.IVJul 15, 2026

Prospective clinical indication, post-hoc report leakage, and fusion design in multi-image chest radiograph classification: a patient-clustered evaluation

Authors: Kamran ShahidMuhammad Munwar Iqbal

Organizations: Department of Computer Science, University of Engineering and Technology, Taxila, Pakistan

Abstract

Chest radiograph datasets often combine multiple images with Clinical Indication, Findings, and Impression, although these inputs are produced at different stages of care. We evaluated 15,000 ReXGradient-160K studies with two readable images and five CheXbert-derived report observations. Frozen DenseNet-121 and Bio+ClinicalBERT encoders were used to compare image-only, Indication-only, fixed-order multimodal, random-swap, DeepSets, and SectionGuard-MI models. Findings and Impression were evaluated only as post-hoc leakage controls. Models were trained with five seeds, and public-test uncertainty was estimated with 2,000 patient-cluster bootstrap replicates. Under U-Ones, macro AUROC was 0.643 for the primary image, 0.694 for two images, 0.749 for Indication, and 0.780 for ordinary two-image-plus-Indication fusion. SectionGuard-MI achieved AUROC 0.783 and AUPRC 0.260. Relative to ordinary fusion, its paired AUROC difference was 0.0031 (95% CI, -0.0042 to 0.0104; adjusted p=0.374), while its AUPRC difference was 0.0289 (95% CI, 0.0095 to 0.0413; adjusted p=0.004). DeepSets had the highest prospective AUROC point estimate (0.787), and random-swap fusion had the highest prospective AUPRC point estimate (0.265) with better calibration than SectionGuard-MI. Full report text alone reached AUROC 0.979 and AUPRC 0.836; AUROC remained above 0.973 after exact or expanded masking. These results show that prospective Indication is strongly associated with report-derived targets, permutation-aware fusion is competitive, and post-hoc report text creates substantial report-label circularity.

Explore similar work

Jun 16, 2026cs.CV

Vision-language models for chest radiography do not always need the image

Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image. That inference is unsafe: a model exploiting finding-name priors scores like one that reads the scan, and no standard benchmark separates them. We introduce a causal audit that intervenes on the image, occluding the relevant region, occluding an irrelevant one, and swapping in another patient's same-label scan, and combines three behavioral metrics to test whether a correct answer depends on the image. Across nine systems, a text-only model with no image access reaches within 5.7 accuracy points of the best multimodal one, and a 119-billion-parameter multimodal model is statistically indistinguishable from a 7-billion text-only baseline. The audit splits the cohort into three models that ignore the image, one that is unstable, and five that use it selectively, for a subset of findings; the categories hold across a second dataset, resolution, and prompt phrasing. Against board-certified radiologists, a text-only model is statistically indistinguishable from a radiologist's accuracy while grounding at zero, whereas the image-using models ground at radiologist-comparable rates. Reported confidence flags ungrounded answers only when a model uses the image. Grounding audits, not accuracy, should gate clinical deployment.
Mahshad Lotfinia, Sebastian Ziegelmayer, Lisa Adams +3
Aug 11, 2026cs.AI

RadFusion: Towards Threshold-Controllable Radiology Report Generation

Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions. A single fixed report can neither adapt to these scenarios nor support the ROC-based validation widely expected for regulatory clearance. We introduce RadFusion, a framework that equips report generation with threshold controllability. Our method fuses a multi-label classifier, which provides per-disease confidence scores, with a VQA-based report generator, which describes medical findings in detail; an LLM then rewrites the report so that its stated diagnoses follow the classifier's decisions at the selected threshold while staying grounded in the generator's descriptions. On MIMIC-CXR, the performance of RadFusion conforms to the classifier's ROC curve: sweeping the threshold and mapping the reports back to class labels reproduces the classifier's validated ROC performance. This conformance makes generated reports quantitatively evaluable through ROC analysis, strengthening the case for regulatory clearance, and enables operating-point selection that matches report behavior to clinical context. Moreover, combining the two model types improves diagnostic accuracy over uncontrolled generation: sensitivity increases by 6.9% at matched specificity, and specificity by 20.7% at matched sensitivity. These results show that RadFusion makes report generation clinically adaptable, quantitatively verifiable, and diagnostically more reliable.
Ying Jin, Noel C. F. Codella, John Corring +3
Jul 8, 2026cs.CV

Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation

Despite rapid advances in chest X-ray (CXR) foundation models, most radiology report generation (RRG) systems still rely on heavily downsampled inputs (e.g., 256x256) due to the fixed visual token budgets of pretrained vision encoders, suppressing subtle yet clinically important cues present in native-resolution images. However, enabling high-resolution (high-res) perception remains challenging: naive tiling causes prohibitive token inflation, while global compression suppresses subtle lesions and degrades diagnostic fidelity. Inspired by radiologists' workflow, localizing suspicious regions before detailed high-res assessment. We propose Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Reporting (LePaX), the first RRG framework that enables efficient high-res CXR perception (up to 1920x1920) without increasing the vision-token count. LePaX formulates high-res perception as a constrained spatial resolution allocation problem under a fixed token budget and introduces two key components: Learnable Spatial Resolution Allocation (LSRA), which learns a spatial utility map that adaptively allocates limited high-res capacity to diagnostically relevant regions, enabling targeted extraction of high-res patches from native CXRs; and Global-Regional Fusion (GRF), which performs token-preserving region-to-global refinement by projecting high-resolution regional evidence back onto the global feature grid through spatially aligned resolution write-back, avoiding token inflation. Experiments on multiple CXR benchmarks demonstrate that LePaX consistently improves both clinical and linguistic metrics while enabling native-resolution CXR perception with over 10x fewer visual tokens than naive high-res tiling.
Yingshu Li, Yunyi Liu, Zhenghao Chen +5