cs.CVAug 14, 2026

TRIAGE: Risk-Controlled Pseudo-Label Admission for Annotation-Efficient Semi-Supervised Retinal OCT Classification

Authors: Md Ashraful Hossen Akash, Shyla Afroge, Abdullah Al Mamun, Md. Kishor Morol, Tze Hui Liew

Organizations: Department of Computer Science & Engineering, Rajshahi University of Engineering & Technology, Rajshahi-6204, Bangladesh · Elite Research Lab LLC, New York, USA · Faculty of Information Science and Technology, Multimedia University, Melaka, Malaysia · Centre for Intelligent Cloud Computing (CICC), COE of Advanced Cloud, Faculty of Information Science & Technology, Multimedia University, 75450, Melaka, Malaysia

Abstract

The advanced retinal disease diagnosing imaging modality, optical coherence tomography (OCT), encounters a lack of automation because of the high expenses for annotations performed by specialists. The use of SSL solves the problem of insufficient annotations using unlabeled B-scans; however, most of the current techniques for generating pseudo-labels are based on prediction confidence without considering the asymmetry between different types of errors. This paper proposes TRIAGE, a risk-controlled semi-supervised framework for OCT scans classification, which uses the concept of a patient-level conformal risk controller with an asymmetric cost matrix. TRIAGE unites three crucial modules: a hierarchical classifier that is capable of working with partially abnormal supervision of the disease subtypes, a patient-grouped conformal risk controller with primal-dual coverage control, and a context-aware Transformer teacher for cross-slice verification. On the dataset from Noor Eye Hospital (16,822 B-scans, 161 patients, and 554 volumes) with a test set of unseen patients, TRIAGE demonstrates 89.66% scan-level accuracy, 0.8805 macro-F1, 0.9641 macro-AUC, and an 8.34% under-grading rate when using only 20% of the labeled data. With only 5% of the labeled data, TRIAGE keeps 76.88% accuracy and a 0.1656 under-grading rate. Compared with the other six state-of-the-art semi-supervised methods, TRIAGE significantly outperforms them with ablation study demonstrating the contribution of each module in the overall framework performance (by 42.7% in terms of under-grading rate comparing to fixed threshold methods). TRIAGE demonstrates 98.00% accuracy for 3-class classification with 1% labeled data and 95.94% accuracy for 8-class classification with 10% labeled data on the OCT-C8 dataset.

Figures & tables

Explore similar work

Jul 20, 2026

PC-Seg: Progressive Cross-View Consistency for 3D OCT Segmentation from Sparse 2D Annotations

Volumetric segmentation of optical coherence tomography (OCT) images is essential for diagnosing ocular diseases but requires labor-intensive voxel-wise annotations. While semi-supervised learning (SSL) can reduce annotation costs, most existing methods process data slice by slice and fail to exploit the inherent 3D spatial context. We propose PC-Seg, a progressive cross-view consistency framework that learns high-accuracy 3D segmentation models from sparse 2D annotations. Unlike conventional multi-view approaches, PC-Seg uses a single 2D model to learn cross-view consistency from standard B-scans and orthogonal slices, thereby generating reliable volumetric pseudo-labels. These pseudo-labels are then distilled into a 3D model, followed by a co-training stage in which the 2D and 3D models mutually refine each other through ensemble pseudo-labeling. Experiments on the MSHC and Duke DME datasets demonstrate that PC-Seg achieves accuracy comparable to fully supervised learning while using labels for only about 0.7% of the training data, outperforming state-of-the-art semi-supervised and retinal layer segmentation methods. Our code is publicly available at https://github.com/gsisaoki/pc-seg-official.
Apr 24, 2026

Anatomy-Aware Unsupervised Detection and Localization of Retinal Abnormalities in Optical Coherence Tomography

Reliable automated analysis of Optical Coherence Tomography (OCT) imaging is crucial for diagnosing retinal disorders but faces a critical barrier: the need for expensive, labor-intensive expert annotations. Supervised deep learning models struggle to generalize across diverse pathologies, imaging devices, and patient populations due to their restricted vocabulary of annotated abnormalities. We propose an unsupervised anomaly detection framework that learns the normative distribution of healthy retinal anatomy without lesion annotations, directly addressing annotation efficiency challenges in clinical deployment. Our approach leverages a discrete latent model trained on normal B-scans to capture OCT-specific structural patterns. To enhance clinical robustness, we incorporate retinal layer-aware supervision and structured triplet learning to separate healthy from pathological representations, improving model reliability across varied imaging conditions. During inference, anomalies are detected and localized via reconstruction discrepancies, enabling both image and pixel-level identification without requiring disease-specific labels. On the Kermany dataset (AUROC: 0.799), our method substantially outperforms VAE, VQVAE, VQGAN, and f-AnoGAN baselines. Critically, cross-dataset evaluation on Srinivasan achieves AUROC 0.884 with superior generalization, demonstrating robust domain adaptation. On the external RETOUCH benchmark, unsupervised anomaly segmentation achieves competitive Dice (0.200) and mIoU (0.117) scores, validating reproducibility across institutions.
Feb 23, 2026

Gradient based Severity Labeling for Biomarker Classification in OCT

In this paper, we propose a novel selection strategy for contrastive learning for medical images. On natural images, contrastive learning uses augmentations to select positive and negative pairs for the contrastive loss. However, in the medical domain, arbitrary augmentations have the potential to distort small localized regions that contain the biomarkers we are interested in detecting. A more intuitive approach is to select samples with similar disease severity characteristics, since these samples are more likely to have similar structures related to the progression of a disease. To enable this, we introduce a method that generates disease severity labels for unlabeled OCT scans on the basis of gradient responses from an anomaly detection algorithm. These labels are used to train a supervised contrastive learning setup to improve biomarker classification accuracy by as much as 6% above self-supervised baselines for key indicators of Diabetic Retinopathy.