UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI
Authors: Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
Organizations: Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA · Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA
MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net
Figures & tables
Fig. 1 : Comparison between conventional PD-DL and the UMPIRE-Net architecture for accelerated MRI reconstruction.
Fig. 2 : Representative reconstruction results for the Cor-PD and Cor-PDFS datasets. In both cases, conventional PD-DL introduces residual artifacts, indicated by the yellow arrows, which are partially reduced by UMPIRE with simple GD. These artifacts are fully removed when using UMPIRE with Nesterov-accelerated GD as the DF solver.
Smoothing Operator
PSNR (dB)
SSIM (−)
Log-Exp [ 19 ]
32.53
0.880
Huber [ 9 ]
34.63
0.886
Quadratic Smoothing
35.11
0.896
Table 2: Ablation study of smoothing operators for UMPIRE (GD) on Cor-PD at R=8 with PF =6/8 .
MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose C+Mag, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.
Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle +2
Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA · Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA · Department of Medicine (Cardiology), University of Minnesota, Minneapolis, MN, USA
Accelerated magnetic resonance imaging (MRI) enabled by the training of deep learning (DL)-based image recon. models requires large and diverse raw k-space datasets. In most clinical MRI applications, due to storage and patient privacy concerns, raw k-space data is discarded and magnitude-only images are the only component saved. Consequently, a large portion of the DL-based MRI recon. literature has either relied on small training datasets or has used one of the few available open-source k-space datasets. At the same time, the growing number of anonymized magnitude-only image registries/databases motivates the development of techniques that can use them as training datasets for generalizable DL-based recon. models. Here we propose to address this challenge by employing a generative approach based on conditional score-based diffusion models (SBDMs): given a magnitude-only MR image, it synthesizes a phase map (in the image domain) that realistically corresponds to the magnitude-only image. We evaluate its generative capabilities in a downstream DL-based recon. task whereby a large k-space dataset is generated by combining the SBDM-synthesized phase-maps and the corresponding magnitude-only images, and this k-space dataset is then used to train a DL model for accelerated MRI recon. We compare the performance of the resulting DL model versus those trained according to (a) a naive approach that uses smooth phase, (b) a k-space training dataset generated using synthesized phase maps derived from a generative adversarial network, and (c) the ground truth k-space data. Our results suggest that the DL model trained from SBDM-synthesized k-space data outperforms the other approaches in terms of quantitative metrics as well as qualitatively observed recon. fidelity, i.e., whether the reconstructed images include erroneous or hallucinated features that could adversely impact diagnostic accuracy.
M. Berk Sahin, Dilek Yalcinkaya, Abolfazl Hashemi +1
Deep unrolled networks (DUNs) integrate physical forward models with learned regularization in cascaded network architectures, achieving exceptional performance in inverse problems while maintaining interpretability. While most DUNs operate in the object domain (e.g., image space), recent variants explored representation spaces for improved information flow. However, these methods rely on heuristic methods for data consistency (DC), sacrificing fidelity with measurements. In this work, we introduce DUNE (Deep Unrolled Networks in rEpresentation space), a framework that maintains exact adherence to physical measurements while operating in learned representation spaces. By deriving the DC gradient via the chain rule and implementing it through the Vector-Jacobian Product (VJP), we enable exact backpropagation of measurement residuals into the representation space. This formulation supports diverse architectural backbones, including pre-trained encoders to guide the iterative process. We assess DUNE against state-of-the-art baselines on accelerated MRI reconstruction tasks, demonstrating that exact VJP-based gradients yield superior reconstruction quality and structural fidelity across both single-channel portable low-field and multi-channel clinical high-field MRI acquisitions. The code will be available upon publication at https://github.com/EfeIlicak/DUNE.
Efe Ilıcak, Baris Imre, Chloé Najac +4
Department of Radiology, Leiden University Medical Center, Leiden, Netherlands