FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making
Organizations: College of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada · Holland Bloorview Kids Rehabilitation Hospital, Toronto, ON M4G 1R8, Canada · Guelph General Hospital, Guelph, ON N1E 4J4, Canada · Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1, Canada
Abstract
Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18% accuracy for anatomical location, 67.96% accuracy for margin characteristics, and 79.13% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9% accuracy, 98.6% completeness score, 76.1% clinical relevance, and an overall score of 89.5%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.
Figures & tables
| Parameter | Precision | Recall | F1-score | Accuracy |
| Anatomical location | 0.75 | 0.72 | 0.70 | 77.18% |
| Margin characteristics | 0.65 | 0.64 | 0.64 | 67.96% |
| Attenuation type | 0.58 | 0.52 | 0.53 | 79.13% |
| Nodule diameter | MAE = 2.58 mm; SD = 3.73 mm; Accuracy = 21.4–87.9% | |||
| Attribute | Pre-trained GPT-4 | Fine-tuned GPT-4 | Human Reference | Proposed Model |
|---|---|---|---|---|
| Location (Accuracy) | 36.31% | 43.68% | – | 77.18% |
| Diameter (MAE) | 4.74 mm | 3.83 mm | 3.2 mm | 2.58 mm |
| Margin (Accuracy) | 38.42% | 39.47% | – | 67.96% |
| Attenuation (Accuracy) | 37.36% | 63.68% | 58–77% | 79.13% |