cs.LGAug 16, 2026

In Defense of OCTA: The Reconstruction-Utility Gap in OCT-to-OCTA Synthesis

Authors: Michael Chertok, Alon Tiosano, Orly Gal-Or, Lior Kramarski, Einav Baharav Shlezinger, Irit Bahar, Lior Wolf

Organizations: MarkerLeap, Raanana, Israel · Rabin Medical Center, Petah Tikva, Israel · Tel Aviv University, Tel Aviv, Israel

Abstract

Optical coherence tomography angiography (OCTA) images retinal blood flow, giving capillary-perfusion and foveal-avascular-zone biomarkers that grade diabetic-retinopathy ischemia. Because OCTA hardware is less common than structural OCT, recent work synthesizes it from OCT, reporting strong reconstruction (3D PSNR > 31 dB, SSIM > 0.9). We ask not whether the synthetic image looks similar, but whether it supports the measurements OCTA is acquired for. A frozen real-OCTA segmenter, applied as a probe to two synthesizers (XOCT, TransPro), shows downstream Dice falling with structural fineness: large vessels survive (0.862 -> 0.831) while the fine capillary network collapses (0.798 -> 0.635, five times the large-vessel loss; paired Wilcoxon p < 1e-3), TransPro worse throughout. A matched-blur control shows this detail is fabricated, not blurred. Retrained on a private Spectralis dataset, neither synthesizer reproduces the neovascular lesion (qualitative, n=3). Reconstruction fidelity is not clinical utility; we establish downstream-task fidelity as the evaluation OCT-to-OCTA synthesis needs.

Figures & tables

Explore similar work

Jun 3, 2026

Three-Dimensional Retinal Microvasculature Restoration in OCT Angiography

Optical coherence tomographic angiography (OCTA) is a powerful technique for imaging retinal microvasculature. However, acquiring reliable quantification of retinal blood flow and areas of retinal nonperfusion is challenging because of imaging artifacts. Existing methods primarily focus on noise suppression, projection artifact removal, or signal enhancement to improve the image quality of OCTA in cross-sectional or two-dimensional (2D) en face projections, while neglecting the intrinsic three-dimensional vascular architecture. In this study, we propose a deep learning-based algorithm for restoring capillary anatomical vasculature from a single OCTA volume. The network consists of an EfficientNet-B5 encoder and a decoder incorporating concurrent spatial and channel squeeze-and-excitation modules, connected via skip connections to preserve spatial resolution. Three adjacent B-frames are used as input to predict the restored middle B-frame. We evaluated the performance of the model using the peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) against ground truth generated from averaging multiple scans. The results show that the proposed model significantly (both p < 0.001) improved image quality compared with the original single OCTA volume, with a PSNR of 26.16 +/- 1.26 vs. 22.23 +/- 0.78 and an SSIM of 0.91 +/- 0.02 vs. 0.72 +/- 0.03. The proposed model also significantly (p < 0.001) improved microvascular fidelity, measured by the Dice coefficient overlap between the model output and ground truth, in both 2D and 3D by at least 3.8% and 51.2%, respectively, across several different vascular slabs.
Jun 15, 2026

Propagating Structural Guidance: Synthesizing Fluorescein Angiography from Fundus Images and Sparse OCT Scans

Fundus fluorescein angiography (FFA) is critical for assessing retinal vascular abnormalities, but its acquisition is invasive and not always feasible. In contrast, color fundus photography (CFP) is non-invasive and widely accessible, which has motivated studies on CFP-to-FFA synthesis. However, prior works rely solely on CFP surface texture, fundamentally limiting the ability to reconstruct functional vascular information and subtle pathological changes. To address this, we propose a novel framework that synthesizes FFA from CFP with structural guidance provided by optical coherence tomography (OCT). We construct a multi-modal retinal imaging dataset with paired CFP, FFA, and OCT from 3,676 patient eyes--the first tri-modally aligned dataset in retinal imaging. To bridge the spatial gap between OCT and fundus modalities, we propose a Spatially Aligned Cross-Modal Fusion (SACMF) module that projects depth-resolved OCT features onto the fundus plane and injects them into the CFP encoder via adaptive layer normalization. Beyond feature fusion, we further introduce Token-wise Cross-Modality Alignment (TCMA), a token-level contrastive learning strategy that explicitly aligns CFP and FFA representations at corresponding spatial positions. Our method achieves superior synthesis performance compared to state-of-the-art methods. Moreover, extensive experiments demonstrate that the FFA images synthesized by our approach bring greater improvements in downstream disease diagnosis performance than existing methods, highlighting the clinical potential of our approach as a non-invasive decision-support tool in routine workflows. The code is available at https://github.com/while-plus/OCT-guide-FFA-Syn.
Jul 4, 2026

Cross-Modal Fusion of OCT and OCT angiography enface for Improved Diagnostics of Diabetic Retinopathy

Diabetic retinopathy (DR) is a leading cause of vision impairment worldwide, highlighting the need for accurate and accessible screening tools. Optical Coherence Tomography (OCT) provides high-resolution structural information of the retina, whereas OCT angiography (OCTA) offers complementary vascular information that is highly relevant for DR diagnosis. In this study, we propose a cross-modal fusion of OCT B-scans with single-channel en face OCTA using a bidirectional cross-modal attention network for automated DR classification. Two independent datasets, OCT500 and UIC, comprising 730 subjects in total, were utilized to evaluate performance under within-dataset, combined-dataset, and cross-dataset generalization settings. A ConvNeXt V2 model trained solely on OCT images served as the unimodal baseline. In addition to ground-truth (GT) OCTA, we explored the use of translated (TR) OCTA generated from OCT scans, eliminating the requirement for dedicated OCTA hardware. Experimental results demonstrate that cross-modal fusion consistently outperforms unimodal OCT classification across all evaluation scenarios. Fusion with GT OCTA improved classification accuracy and discriminative performance, while TR OCTA achieved comparable or superior results in most settings. Furthermore, TR OCTA improved sensitivity and cross-dataset generalization, indicating enhanced robustness to domain shifts. These findings demonstrate that attention-based OCT-OCTA en face fusion provides clinically meaningful improvements for DR detection and suggest that computationally generated OCTA can serve as a practical, low-cost alternative to hardware-acquired OCTA, enabling broader deployment of high-performance retinal screening systems in resource-limited clinical environments.