cs.CVAug 18, 2026

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

Authors: Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia

Organizations: School of Computer Science, Northwestern Polytechnical University, Xi’an, China · Imperial College London, London, UK · Department of Brain Sciences, Imperial College London, London, UK · Australian Institute for Machine Learning (AIML), Adelaide University, Adelaide, Australia · 

Abstract

X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

Figures & tables

Explore similar work

Mar 27, 2026

Conditional Diffusion for 3D CT Volume Reconstruction from 2D X-rays

Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited availability. Standard chest X-rays are cost-effective and widely accessible, but provide only 2D projections with limited pathological information. Reconstructing 3D CT volumes from 2D X-rays could markedly increase diagnostic accessibility, yet existing methods rely predominantly on synthetic X-ray projections, limiting clinical generalization. We propose AXON, a multi-stage diffusion-based framework that reconstructs 3D CT volumes directly from real X-rays with substantially improved fidelity over existing approaches. AXON follows a coarse-to-fine paradigm: a Brownian Bridge diffusion model first captures global anatomical structure, and a ControlNet-guided refinement stage then enhances local intensity detail and anatomical realism. To alleviate the depth ambiguity inherent in 2D-to-3D reconstruction, AXON incorporates bi-planar X-ray views, enabling more accurate spatial reasoning and structural recovery. A dedicated super-resolution module further increases the spatial resolution of the generated volumes. Experiments on public and external datasets show that AXON consistently surpasses state-of-the-art approaches while generalizing across diverse clinical distributions. At our highest-resolution bi-planar setting, AXON achieves an 11.9% improvement in PSNR and an 11.0% increase in SSIM over the strongest baseline evaluated at that resolution. In the 1283128^3 single-planar setting, it maintains a lead of 7.8% in PSNR on LIDC-IDRI, with larger margins on the external clinical dataset of 8.0% in PSNR and 16.9% in SSIM. Our code is available at https://github.com/ai-med/AXON/.
Sep 9, 2026

Multi-Pass, Multi-View Blended Learning for High-Fidelity Volumetric CT Synthesis from Chest X-Rays

Reconstructing volumetric Computed Tomography (CT) from a single 2D chest radiograph (CXR) is an ill-posed inverse problem, further complicated by the scarcity of paired CXR-CT training data. Prior approaches address this by training on Digitally Reconstructed Radiographs (DRRs), which are synthetic projections derived from CT volumes. However, the domain gap between DRRs and real CXRs limits generalization, often resulting in coarse or anatomically inconsistent reconstructions when applied to clinical images. To address this challenging problem, this study introduces a Multi-Pass Multi-View Blended Learning framework for synthesizing high-fidelity volumetric CT directly from real chest X-ray (CXR) images. The proposed approach progressively decomposes the synthesis task into two distinct, complementary learning stages. Stage 1 is an unsupervised CXR-to-DRR Domain Adaptation, while Stage 2 includes three passes, namely, (a) supervised DRR-to-CT Transformation, (b) unsupervised Multi-View Slice Refinement, followed by (c) Progressive Transfer Learning (PTL). With such a blended learning paradigm, the proposed approach mitigates the synthetic-to-real domain gap while enhancing both the structural integrity and anatomical detail of the final output. On the LIDC-IDRI dataset, where paired DRR-CT ground truth is available for quantitative evaluation, the proposed method improves upon prior methods by up to 14% in PSNR and 7.6% in SSIM. The framework successfully generates structurally consistent and anatomically realistic high-fidelity CT volumes from real CXRs, marking a significant advancement toward clinical viability of CT reconstruction from standard radiographic images.
Apr 1, 2026

HICT: High-precision 3D CBCT reconstruction from a single X-ray

Accurate 3D dental imaging is vital for diagnosis and treatment planning, yet CBCT's high radiation dose and cost limit its accessibility. Reconstructing 3D volumes from a single low-dose panoramic X-ray is a promising alternative but remains challenging due to geometric inconsistencies and limited accuracy. We propose HiCT, a two-stage framework that first generates geometrically consistent multi-view projections from a single panoramic image using a video diffusion model, and then reconstructs high-fidelity CBCT from the projections using a ray-based dynamic attention network and an X-ray sampling strategy. To support this, we built XCT, a large-scale dataset combining public CBCT data with 500 paired PX-CBCT cases. Extensive experiments show that HiCT achieves state-of-the-art performance, delivering accurate and geometrically consistent reconstructions for clinical use.