cs.CVAug 18, 2026

PerFact: Perception-Derived Fact Prompting for 3D Brain MRI Report Generation

Authors: Jianyu Sun, Zhenxuan Zhang, Guang Yang, Peter J. Lally

Organizations: Department of Bioengineering, Imperial College London, London, UK · Imperial-X, Imperial College London, London, UK · School of Biomedical Engineering & Imaging Sciences, King’s College London, London, UK

Abstract

Radiology report generation has matured almost entirely on 2D chest radiographs, where the default route to better reports is a larger backbone or a pre-training one on medical data. We revisit that assumption on 3D multi-sequence brain MRI, a volumetric multi-disease regime, and find that the model is not the lever. Zero-shot medical and radiology vision-language models transfer poorly to brain MRI, with chest radiograph specialists failing most conspicuously, and five backbones fine-tuned identically across three model families and an order of magnitude in scale differ only marginally. What determines the quality of the report is the information injected into the prompt. We delegate perception to upstream 3D segmentation and classification, serialize their outputs into a structured fact sentence, and prompt a LoRA-adapted vision-language model with it; we call this PerFact. In a controlled study that fixes the backbone, data split, target reports, and adaptation while varying only the injected grounding, perception-derived facts outperform retrieved prior reports, retrieval becomes redundant once facts are present, and end-to-end predicted facts remain effective without any ground-truth annotation at inference. The residual gap between predicted and oracle facts is explained by the granularity of the facts rather than by the generator. Closed-ended visual question answering comes at no measurable cost to report quality, though the grounding source has little effect on it. On 3D brain MRI, grounding information, not model choice, is the dominant controllable factor in report quality.

Figures & tables

Explore similar work

Feb 25, 2026

Brain3D: Brain Report Automation via Inflated Vision Transformers in 3D

Current medical vision-language models (VLMs) process volumetric brain MRI using 2D slice-based approximations, fragmenting the spatial context required for accurate neuroradiological interpretation. We developed Brain3D, a staged vision-language framework for automated radiology report generation from 3D brain tumor MRI. Our approach inflates a pretrained 2D medical encoder into a native 3D architecture and progressively aligns it with a causal language model through three stages: contrastive grounding, supervised projector warmup, and LoRA-based linguistic specialization. Unlike generalist 3D medical VLMs, Brain3D is tailored to neuroradiology, where hemispheric laterality, tumor infiltration patterns, and anatomical localization are critical. Evaluated on 468 subjects (BraTS pathological cases plus healthy controls), our model achieves a Clinical Pathology F1 of 0.951 versus 0.413 for a strong 2D baseline while maintaining perfect specificity on healthy scans. The staged alignment proves essential: contrastive grounding establishes visual-textual correspondence, projector warmup stabilizes conditioning, and LoRA adaptation shifts output from verbose captions to structured clinical reports\footnote{Our code is publicly available for transparency and reproducibility
Nov 23, 2024

Improving Factuality of 3D Brain MRI Report Generation with Paired Image-domain Retrieval and Text-domain Augmentation

Acute ischemic stroke (AIS) requires time-critical decision-making, where inaccurate interpretation of neuroimaging findings can lead to irreversible disability. Diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps from magnetic resonance imaging (MRI) are central to detecting acute infarction, yet generating factually reliable radiology reports directly from 3D MRI remains challenging due to the difficulty of learning robust cross-modal alignments between volumetric images and clinical text. We propose paired image-domain retrieval and text-domain augmentation (PIRTA), a retrieval-augmented generation framework that improves report factuality by avoiding explicit image-text alignment. PIRTA retrieves clinically similar 3D DWI/ADC volumes using a pretrained 3D vision encoder and leverages their paired clinician-authored reports to ground large language model (LLM)-based report generation. Experiments on multi-institutional in-house data, a held-out external privacy-preserving cohort, and the public ISLES benchmark demonstrate that PIRTA achieves strong image-domain retrieval performance and consistently improves ischemic-territory accuracy, a clinically grounded surrogate for report factuality, compared to direct image-to-text baselines. These results indicate that retrieval-grounded generation provides a scalable and reliable paradigm for producing factually consistent radiology reports from complex 3D brain MRI. Source code is available at https://github.com/jhlee0619/PIRTA.
Sep 1, 2026

BrainDiff: Longitudinal Report Generation for Multimodal Brain MRI

Neuroradiologists rarely read a brain MRI in isolation, yet automated brain-MRI report generation has been built almost entirely for single studies. Temporal analysis has been explored on chest radiography and chest CT, but to our knowledge, longitudinal reporting for brain MRI, where interval change is often subtle and spatially distributed, remains unaddressed. We present BrainDiff, the first longitudinal vision-language system for brain MRI. BrainDiff outperforms both frontier general-purpose and single-study neuroimaging models on the same patient pairs. Moreover, BrainDiff retains 91% of internal RadGraph-XL entity+relation F1 (rg_er) on an external, cross-hospital cohort. Beyond the system, we contribute three analyses. First, we identify two independent grounding levers: a counterfactual objective with prior-report dropout, which increases measured image reliance by ~47%, and a staged curriculum. Together, these interventions raise image reliance 2.5-fold from the baseline. Second, we provide a factorial over prior-report availability and image identity, isolating a visual contribution of +0.0387 rg_er, which grows when the prior report is withheld. Third, a cheap change-decodability test for candidate backbones shows that interval change is decodable far more weakly than single-study pathology (0.60 vs. 0.77 AUROC). Code is publicly available at https://github.com/jhuldr/BrainDiff.