cs.CVAug 18, 2026

Bound-Aware Per-Organ Recall Risk Control for Multi-Organ CT Segmentation under Clinical Domain Shift

Authors: Souraj Adhikary, Negar Chabi, Andre Mastmeyer

Organizations: Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, Germany

Abstract

Distribution-free risk control adds organ-specific recall guarantees to frozen segmentation. We calibrate per-organ thresholds for an AMOS-trained nnU-Net, audit transfer to RAOS, and estimate local re-certification cost using case-level voxel false-negative rate (FNR). The AMOS control passes, but 7/127/12 organs exceed α=0.10α{=}0.10 after transfer; smaller calibration sets can mask exceedances with conservative or vacuous thresholds. Risk-Controlling Prediction Sets (RCPS) give high-probability control of population-mean risk, whereas Conformal Risk Control (CRC) gives weaker expectation control. Both require exchangeability; fixed and global thresholds give no per-organ guarantee. The Waudby--Smith--Ramdas (WSR) betting bound re-certifies six Tier-1 organs with 25 local cases, versus 30--40 for Hoeffding--Bentkus (HB). CRC needs 10--15 but has a heavier individual-case tail. No Tier-2 organ meets our illustrative precision criterion with 25 cases.

Figures & tables

Explore similar work

CardsList
  1. ReCIRC: Rectified Conformal Risk Control

    Sep 29, 2026Bruno Marcondes e Resende, Helton Graziadei, Thiago Rodrigo Ramos +1Conformal PredictionConformal Risk Control

  2. Budget-Aware Uncertainty for Radiotherapy Segmentation QA Using nnU-Net

    Apr 13, 2026Ricardo Coimbra Brioso, Lorenzo Mondo, Damiano Dei +4Segmentation Uncertainty EstimationMedical Image Segmentation