Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.
The increasing interest in data-driven methods for power system protection is accompanied by a lack of standardized, publicly available high-voltage waveform datasets that enable transparent and reproducible evaluation. To address this gap, this paper introduces the PROTECT-90 dataset, an open electromagnetic transient (EMT)-simulated reference benchmark for high-voltage fault studies with consistent digital-fault-recorder-like measurements, publicly released with this work. The dataset comprises 9,022 physically consistent short-circuit simulation episodes generated on a standardized 90 kV double-line topology with systematically documented domain randomization of grid operating points, line parameters, and fault conditions. For each episode, synchronized three-phase voltage and current waveforms are recorded at eight measurement locations and released together with structured, machine-readable metadata describing fault type, fault location, inception time, and operating conditions. All modeling assumptions, parameter ranges, and data-generation procedures are explicitly documented to ensure transparency and cross-study comparability. By combining physically grounded EMT simulation, balanced scenario coverage, and open accessibility, PROTECT-90 establishes a standardized foundation for reproducible benchmarking of protection-oriented signal processing and learning-based methods.
Julian Oelhaf, Georg Kordowich, Christian Bergler +3
Executable evaluation -- checking the consequences of an agent's actions with a program rather than grading its prose -- has become a prominent way to assess tool-using AI agents in software settings. Electric power engineering has not yet had an analogous benchmark: language-model use is still dominated by retrieval and text question answering, while agents acting on power-system artifacts remain mostly academic prototypes. We introduce the Power Systems Agent Benchmark, an executable benchmark for power-engineering agents. An agent receives a structured task and returns a structured solution; a deterministic evaluator recomputes the engineering quantities, checks operational constraints, and returns a feasibility flag, a normalized score, and explicit violations. The benchmark contains 41 task families across eight areas of power engineering, from power flow and protection to stability, microgrids, reliability, power quality, and forecasting. Each task is grounded in a citable source, standard, or documented engineering formulation. To resist contamination, held-out cases are synthesized on demand by per-family generators from private seeds: the construction is inspectable, but the instances remain private. In a reference evaluation with three command-line agents, the strongest score near the compact tier's ceiling, a smaller open model trails, and public and held-out performance are broadly consistent; a separate public-split grid with OpenCode and Aider probes harness effects. The reference evaluation doubles as quality control: unanimous failures flag candidate task or evaluator defects, and it exposed a latent evaluator bug missed by self-consistency checks. The evaluators are compact deterministic surrogates, but the task contract allows their internals to be upgraded to simulator-backed checks without changing how tasks are posed or solved.
This work introduces a latency-aware benchmarking framework for evaluating deep learning models in power system anomaly detection using high-fidelity, time-domain signals generated from an industry-grade electromagnetic transient simulator. Eight neural network architectures, ranging from MLPs to Transformers, were systematically evaluated on streaming datasets representing both physical faults and cyber-attacks in inverter-dominated networks. All models successfully classified two representative multi-event sequences in real time with sub-cycle response times below 15 ms. However, although classification decisions occurred within one cycle, the end-to-end inference latency consistently exceeded three cycles, ranging from 50 to 90 ms. These results highlight a critical gap between algorithmic capability and protection-grade deployment, pointing to the need for further optimization and hardware acceleration. The findings establish a reproducible benchmark for sub-cycle anomaly detection and provide guidance for transitioning machine learning methods from research prototypes to real-world protection applications.
Emad Abukhousa, Saman Zonouz, A. P. Sakis Meliopoulos