cs.CVSep 29, 2026

Anatomy-Aware Prediction of Bronchoscopic Accessibility from 3D CT

Authors: Linkai Peng, Cuiling Sun, Bin Wang, Jamie Rowell, Catherine Gao, Oyku Ikizgul, Eminenur Sentasci, Andrea Bejar, +5 more

Organizations: Department of Electrical and Computer Engineering, Northwestern University · Department of Computer Science, Northwestern University · Department of Medicine, Northwestern University · Department of Radiology, Istanbul Faculty of Medicine · Department of Radiology, Northwestern University

Abstract

Pre-operative planning for bronchoscopy is critical for the diagnosis of lung lesions. Current accessibility assessment relies on subjective manual inspection of CT scans, which is time-consuming and prone to inter-observer variability. In this paper, we formalize bronchoscopy accessibility prediction as a novel supervised learning task and present the first end-to-end framework to address it. We propose an Anatomy-Aware Mixture-of-Experts (MoE) model that integrates specialized modules: a CT Expert for local morphological features, a Lobe Expert for anatomical priors, and a Path Geometry Expert that encodes the sequential constraints of the bronchial tree. To support this task, we curated the first clinical dataset of 438 cases with pre-operative CT scans and documented procedural outcomes. Experimental results demonstrate that our method achieves an AUROC of 0.8052, significantly outperforming both state-of-the-art baselines and experienced human experts. This work establishes a new benchmark for computer-aided interventional planning in pulmonary medicine. Our data and code will be publicly available at https://nubagcilab.github.io/BronchoAccess/.

Figures & tables

Explore similar work

Sep 23, 2026cs.CV

BronchoTop: Bronchoscopy Navigation via RGB-Only Topological Localization

Accurate localization of the bronchoscope within the bronchial tree is essential for clinicians to be able to reach target lesions, perform biopsies and avoid misidentification of airway segments during diagnostic and therapeutic procedures. However, existing navigation systems typically rely on patient-specific CT scans or additional external sensors, increasing cost, setup time and patient radiation exposure. This work presents BronchoTop, a real-time, RGB-only framework for topological bronchoscopy localization that eliminates the need for patient-specific data. BronchoTop estimates scope location relative to a generic airway model through four modules: lumen detection and tracking, lumen-branch label association, probabilistic scope location estimation, and switch verification. By using only standard bronchoscopy video input, BronchoTop provides practical, real-time navigational assistance to physicians. Evaluation on phantom, simulated and real data demonstrates state-of-the-art accuracy, improving existing approaches performance by over 20% on real bronchoscopy sequences. BronchoTop is the first published framework including both the localization algorithms as well as all the real data used, together with code to generate additional simulations, encouraging and facilitating further developments and benchmarking. The results highlight BronchoTop's potential to enhance procedural safety, efficiency and accessibility in clinical and robotic bronchoscopy.
Apr 30, 2026cs.CV

Stop Holding Your Breath: CT-Informed Gaussian Splatting for Dynamic Bronchoscopy

Bronchoscopic navigation relies on registering endoscopic video to a preoperative CT scan, but respiratory motion deforms the airway by 5-20 mm, creating CT-to-body divergence that limits localization accuracy. In practice, this is mitigated through breath-hold protocols, which attempt to match the intraoperative anatomy to a static CT, but are difficult to reproduce and disrupt clinical workflow. We propose to eliminate the need for breath-hold protocols by leveraging patient-specific respiratory modeling. Paired inhale-exhale CT scans, already acquired for planning, implicitly define the patient-specific deformation space of the breathing airway. By registering these scans, we reduce respiratory motion to a single scalar breathing phase per frame, constraining all reconstructions to anatomically observed configurations. We embed this representation within a mesh-anchored Gaussian splatting framework, where a lightweight estimator infers breathing phase directly from endoscopic RGB, enabling continuous, deformation-aware reconstruction throughout the respiratory cycle without breath-holds or external sensing. To enable quantitative evaluation, we introduce RESPIRE, a physically grounded bronchoscopy simulation pipeline with per-frame ground truth for geometry, pose, breathing phase, and deformation. Experiments on RESPIRE show that our approach achieves geometrically faithful reconstruction, over 20x faster training, and 1.22 mm target localization accuracy (within the 3mm clinically relevant tolerances) outperforming unconstrained single-CT baselines. Please check out our website for additional visuals: https://asdunnbe.github.io/RESPIRE/
May 12, 2026cs.CV

BronchoLumen: Analysis of recent YOLO-based architectures for real-time bronchial orifice detection in video bronchoscopy

Bronchoscopy is routinely conducted in pulmonary clinics and intensive care units, but navigating the complex branching of the respiratory tract remains challenging. This paper introduces BronchoLumen, a real-time YOLO-based system for detecting bronchial orifices in video bronchoscopy, aiming to assist navigation and CAD systems. The paper investigates if bronchial orifices can be robustly detected across image domains using state-of-the-art object detection and a limited set of public image data. The study includes the description and comparison of YOLOv8, a widely adopted architecture, and YOLOv12, a more recent architecture integrating attention-based modules to improve spatial reasoning. Both models are trained and tested solely on publicly available datasets comprising different image domains. A comparison of both models is conducted based on the common metrics mAP@0.5 and mAP@0.5:0.9 with the latter emphasizing localization accuracy. For YOLOv8 we obtained a mAP@0.5 of 0.91 on an in-domain and 0.68 on a cross-domain test set. YOLOv12 achieved 0.84 and 0.68 respectively with slightly better localization accuracy with mAP@0.5:0.9 of 0.48 and 0.26 compared to YOLOv8 with 0.45 and 0.25. Challenges like motion blur and low contrast occasionally entailed uncertainties but the system demonstrated overall robustness in most scenarios. BronchoLumen is an open-weight, YOLO-based solution for bronchial orifice detection offering high accuracy and efficiency across multiple image domains. While the more recent YOLOv12 achieves better localization accuracy, we observed a slightly worse precision. The models have been made publicly available to foster further research in bronchoscopy navigation.