Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy
Authors: Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel, Alexandra Bennett, Keldon K. Lin, Terence T. Sio, Jonathan B. Ashman, Lisa A. McGee, Jean-Claude M. Rwigema, William G. Rule, Sameer R. Keole, Sujay A. Vora, William W. Wong, Nathan Y. Yu, Michele Y. Halyard, Steven E. Schild, Safia K. Ahmed, Daniel J. Ma, Robert L. Foote, Michelle A. Neben Wittich, Thomas J. Whitaker, Haibo Lin, Dinggang Shen, Wei Liu
Organizations: Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA · School of Biomedical Engineering, ShanghaiTech University, Shanghai, China · Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA · Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA · New York Proton Center, New York, New York, USA
Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.
Medical image registration aligns scans across time, patients, or imaging modalities to track anatomy and support diagnosis, treatment, and image-guided procedures.
Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA · School of Biomedical Engineering, ShanghaiTech University, Shanghai, China · Shanghai United Imaging Intelligence Co., Ltd., Shanghai 200230, China +2
Fraunhofer Institute for Digital Medicine MEVIS, Lübeck, Germany · Varian, a Siemens Healthineers company, Dättwil, Switzerland · Icon Group, South Brisbane, QLD, Australia