Abstract

Reliable panoramic-radiograph detection requires consistency across datasets with different class definitions and deployment software. We present PanoDent-KD, an auditable 1280-pixel YOLO26m pipeline linking a 12-class source generalist, feature-level knowledge distillation (KD), exact classifier-row transfer, teacher-free five-class specialization, and embedded deployment. A common training and evaluation pipeline compares three source-training arms across three seeds: a supervised baseline (B1), single-teacher KD (STKD), and multi-teacher KD (MTKD). Five shared classifier rows initialize nine OralXrays-9 specialists, while the backbone, FPN-PAN neck, and dual-detection-head topology are retained unchanged. On the 2,686-image test subset, all three arms achieve macro box F1 near 0.82. B1 achieves the highest three-seed arm-level mean macro box F1 (0.8239±\pm0.0027) and mAP50:95mAP_{50:95} (0.6130±\pm0.0067). STKD seed 1, selected after development but before final testing, was used for deployment. Its Jetson Orin Nano Super FP16 TensorRT engine achieves 77.03-ms median and 80.86-ms P95 prediction-call latency, throughput of 12.90 images/s, and gross total-module energy of 1.39 J/image, with high numerical agreement between within-device PyTorch and TensorRT FP16 inference. These findings demonstrate the feasibility of an auditable, device-specific deployment workflow, but do not establish clinical validity or improved target-domain accuracy from KD.

Figures & tables

Explore similar work

Apr 17, 2026

Dental Panoramic Radiograph Analysis Using YOLO26 From Tooth Detection to Disease Diagnosis

Panoramic radiography is a fundamental diagnostic tool in dentistry, offering a comprehensive view of the entire dentition with minimal radiation exposure. However, manual interpretation is time-consuming and prone to errors, especially in high-volume clinical settings. This creates a pressing need for efficient automated solutions. This study presents the first application of YOLOv26 for automated tooth detection, FDI-based numbering, and dental disease segmentation in panoramic radiographs. The DENTEX dataset was preprocessed using Roboflow for format conversion and augmentation, yielding 1,082 images for tooth enumeration and 1,040 images for disease segmentation across four pathology classes. Five YOLOv26-seg variants were trained on Google Colab using transfer learning at a resolution of 800x800. Results demonstrate that the YOLOv26m-seg model achieved the best performance for tooth enumeration, with a precision of 0.976, recall of 0.970, and box mAP50 of 0.976. It outperformed the YOLOv8x baseline by 4.9% in precision and 3.3% in mAP50, while also enabling high-quality mask-level segmentation (mask mAP50 = 0.970). For disease segmentation, the YOLOv26l-seg model attained a box mAP50 of 0.591 and a mask mAP50 of 0.547. Impacted teeth showed the highest per-class average precision (0.943), indicating that visual distinctiveness influences detection performance more than annotation quantity. Overall, these findings demonstrate that YOLOv26-based models offer a robust and accurate framework for automated dental image analysis, with strong potential to enhance diagnostic efficiency and consistency in clinical practice.
Sep 18, 2026

Detection is solved, delineation is not: what governs tooth segmentation on panoramic radiographs

Automatic tooth segmentation and FDI numbering on panoramic radiographs underpins computer-assisted dental diagnosis, yet which factors govern performance remains unclear. We assemble a corpus of 1,422 panoramic radiographs containing 42,142 expert-delineated tooth polygons across the 32-class FDI taxonomy, annotated by 30 dental practitioners and independently reviewed by two others, and use it to isolate input resolution, architecture and anatomical priors under a single evaluation protocol. First, resolution dominates: across a controlled 640/1024/1280 ablation, mask mAP50-95 rises 0.656 -> 0.710 -> 0.717 while mAP50 stays flat at ~0.982. Both gains are significant under a paired bootstrap over images (p < 0.001, p = 0.024); neither mAP50 change is distinguishable from zero. Added resolution buys boundary precision, not detection. Second, architecture is nearly irrelevant in-domain: a query-based transformer with 2.1x the parameters is statistically equivalent to a one-stage detector (95% CI [-0.0064, +0.0064]), only marginally better under domain shift, 5.5x slower on CPU and not executable under standard ONNX runtimes. Third, three targeted interventions fail: a LoRA-adapted self-supervised encoder underperforms, a promptable foundation segmenter degrades masks by 39%, and globally optimal anatomical label assignment yields +0.0007 despite correcting a constraint violated in 40% of out-of-domain predictions. Zero-shot transfer to an independent multi-centre cohort, verified overlap-free, costs 62% of mask mAP50-95 but only 18% of mAP50, reproducing the dissociation. Decomposing masks along the tooth axis localises the residual error to the apical third. Boundary precision is therefore the binding constraint, and effort is better directed at resolution and acquisition diversity than at architectural novelty.
Jul 28, 2026

OrthKD: Extracting Generalized Clinical Knowledge from Heterogeneous Teachers for Lightweight Deployment

Deploying diabetic retinopathy (DR) screening models in primary care requires edge-efficient systems that remain accurate, safe, and reliable under domain shift. Multi-teacher knowledge distillation (KD) is a natural compression strategy, but existing approaches largely assume that all teachers provide equally trustworthy supervision. In our setting, this assumption fails: a strong CNN teacher (EfficientNet-B3, 0.876 QWK) and a weaker Transformer teacher (Swin-Base, 0.830 QWK) are complementary, yet the Transformer's logits can still mislead the student. We therefore propose OrthKD, a selective-trust distillation framework that transfers full supervision from the strong CNN, uses feature-only distillation from the weak ViT, and enforces orthogonality between teacher-specific student projections to encourage complementary rather than redundant evidence. This design preserves local lesion precision, injects global structural context, and improves robustness to distribution shift. On 132,049 retinal images, a 5.4M-parameter MobileNetV3 student reaches 0.885 QWK on EyePACS and improves zero-shot Messidor-2 performance from 0.507 to 0.728 QWK, while also achieving strong referral AUC and calibration. These results show that selectively distilling heterogeneous teachers can enable practical DR screening on resource-constrained devices.