Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease
Organizations: National Institute of Health Data Science, the Institute of Medical Technology, Peking University · Beijing University of Posts and Telecommunications · National Institute of Health Data Science, the Institute of Medical Technology, and the State Key Laboratory of General Artificial Intelligence, Peking University
Abstract
Radar heart sounds capture cardiac mechanical activity without contact, while echocardiography characterizes ventricular and valvular function. Paired measurements connect these signals to structural heart disease, yet such data remain sparsely represented in public resources. Here we present 537 radar heart-sound recordings paired with one echocardiographic report for each of 162 patients. The cohort covers three overlapping phenotypes: left ventricular ejection fraction (LVEF) below 50%, regional wall-motion abnormality and at least moderate valvular regurgitation, present in 38, 43 and 39 patients, respectively. Original complex signals, processed radar heart sounds and temporal quality segmentation support signal-to-phenotype analysis. Technical validation retains 95.93% of signal duration and confirms reproducible waveform reconstruction. Patient-level five-fold evaluation achieves a mean outer-test AUROC of for reduced LVEF, identifying mechanical information associated with ventricular systolic dysfunction. This resource supports research linking non-contact cardiac mechanical signals to echocardiographic structural and functional phenotypes.
Figures & tables
| Characteristic | All | LVEF | RWMA | Valve disease |
|---|---|---|---|---|
| Patients | 162 | 38 | 43 | 39 |
| Male | 109 (67.3%) | 30 (78.9%) | 29 (67.4%) | 23 (59.0%) |
| Female | 53 (32.7%) | 8 (21.1%) | 14 (32.6%) | 16 (41.0%) |
| Age, mean (SD), years | 63.22 (13.00) | 62.21 (16.43) | 64.19 (11.11) | 68.08 (11.69) |
| LVEF, mean (SD), % | 59.75 (14.58) | 37.65 (8.68) | 50.64 (8.80) | 54.87 (17.96) |
| Age, median (IQR), years | 66.5 (56.2–72.0) | 68.0 (50.2–73.0) | 67.0 (56.5–73.0) | 69.0 (65.0–75.5) |
| Parameter | Setting | Interpretation |
|---|---|---|
| RF board / acquisition board | TI IWR1443 / DCA1000EVM | Non-contact FMCW front end and raw-data capture |
| Transmit / receive configuration | 1TX4RX | TX0 enabled; TX1/TX2 disabled; four complex receive channels |
| Chirp start frequency | 77.000 GHz | FMCW profile start |
| Frequency slope | 63.343 MHz/ s | Linear frequency modulation |
| Idle / TX start time | 10.00 / 1.00 s | Chirp timing settings |
| ADC start / ramp-end time | 6.00 / 63.14 s | Sampled aperture within the ramp |
| Representation | Extent | Analytical role |
|---|---|---|
| Original complex radar signal | 60,000 by 512 per recording | Complex I/Q representation for the evaluated RX3 channel; supports range selection and phase-based signal extraction |
| Processed RHS | 60,000 samples at 1,000 Hz per recording | Signed cardiac-related vibration waveform; normalized amplitude is used for waveform illustrations and reconstruction comparisons |
| Temporal quality segmentation | Reviewed intervals on each 60-s time axis | Retained and excluded intervals following outlier screening and manual review; supports quality-aware exposure and spectral analysis |
| Experiment / metric | Unit / | Observed result |
| RHS numerical integrity | Recordings / 537 | All 60,000-point vectors finite and nonconstant |
| Quality interval accounting | Recordings / 537 | No kept-plus-deleted duration discrepancy above 2 ms |
| Retained signal exposure | Recordings / 537 | 30,908.45 s total; 95.93% of nominal duration |
| Retained duration, s | Recordings / 537 | 58.77 (56.25–60.00); minimum 40.04 |
| Quality-masked centroid, Hz | Recordings / 537 | 20.89 (20.19–21.66) |
| Processed band-power fraction | Recordings / 537 | 0.873 (0.826–0.905) |