cs.LGOct 22, 2026

The Value of System 1 Models in Medicine

Authors: Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt, Johannes Moll, Anirudh Narayanan, Frederike Stumpf, 

Organizations: Department of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, Munich, Germany · Artificial Intelligence and Translational Imaging Lab, Department of Radiology, School of Medicine, University of Crete, Heraklion, Greece · Department of Medical Imaging, University Hospital of Heraklion, Heraklion, Crete, Greece · Department of Medicine III, School of Medicine and Health, Technical University of Munich, Munich, Germany · 

Abstract

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

Figures & tables

Appendix figures & tables8 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. A general-purpose System One decision model for clinical records

    Oct 19, 2026Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner +14EHR QAEHR Foundation Models

  2. System1-Arena: Which Decisions Can Be Left to System 1?

    Oct 15, 2026Tianyu Chen, Xinyang Liu, Ruyi An +2LLM Decision-MakingLLM Evaluation

  3. How Reliable Are System-One Decisions in Medicine? A Comparative Study of Jev, Jev-like Models, and LLMs

    Oct 13, 2026Yanrui Du, Danyang Zhao, Sendong Zhao +6Clinical Decision-MakingLLM Reliability