Organizations: Institute for AI in Medicine (IKIM), University Hospital Essen, Girardetstraße 2, 45131, Essen, Germany. · Department of Physics, Technical University Dortmund, Otto-Hahn-Straße 4a, 44227, Dortmund, Germany. · Division of Radiology, German Cancer Research Center (DKFZ), 69120, Heidelberg, Germany. · Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany. · 

Abstract

Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

Figures & tables

Explore similar work

CardsList
  1. Automated Prostate Gland Segmentation in MRI Using nnU-Net

    Apr 2, 2026Pablo Rodriguez-Belenguer, Gloria Ribas, Javier Aquerreta Escribano +3Medical Image SegmentationMagnetic Resonance Imaging

  2. Deep Learning Segmentation of Diffusion-Weighted MRI Acute Ischaemic Stroke: A Pragmatic Evaluation Across Three Datasets

    Aug 26, 2026Atle Bjørnerud, Till Schellhorn, Thor H. Skattør +4Medical Image SegmentationU-Net

  3. Multiple Myeloma Lesion Segmentation on Whole-Body Diffusion-Weighted Imaging via Efficient Anatomical Anticipation and Multimodal Confirmation

    Sep 5, 2026Mengmeng Zhang, Shengqian Huang, Junde Zhou +12Medical Image SegmentationCross-Modality Medical Image Segmentation