cs.ROOct 30, 2026

Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma

Authors: Francis Fan, Mackenzie A Eagleson, Yvonne Zhang, Hongting Pan, Lujia Yang, Ethan Kilmer, Jiawei Ge, Nural Yilmaz, 

Organizations: Laboratory of Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21218, USA · Department of Surgery, Johns Hopkins Medicine, Baltimore, MD 21287, USA · Brady Urological Institute, Johns Hopkins University, Baltimore, MD 21287, USA

Abstract

Uncontrolled hemorrhage remains a leading cause of preventable trauma mortality. Timely intervention is not always available, making autonomous systems that can aid in bleeding control a promising alternative. Given the safety-critical nature of the task, supervised autonomy, in which the system executes the technical steps while a human retains oversight, represents a necessary intermediate step toward this goal. In this work, we present a supervised autonomous bimanual robotic framework for injury cauterization (eletrosurgical coagulation) in low-grade splenic trauma. The system integrates real-time bleeding segmentation, markerless tool keypoint tracking, and deep tool-tissue contact detection to coordinate two robotic arms for synchronized suction and cauterization. Evaluated on a novel, cannulated ex vivo splenic hemorrhage model, the system achieved an average bleeding surface cauterization coverage of 82.9% across seven distinct injuries. This work demonstrates the feasibility of using a supervised autonomous bimanual system to deliver targeted coagulation across an injury site.

Figures & tables

Explore similar work

Oct 20, 2026

Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection

Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue. Histological analysis was performed to detect thermal injury extent at a cellular level, and 3D photogrammetric measurement was used to verify margin accuracy. ThERMO's performance was compared against two previously used fixed velocity methods. Results: ThERMO outperformed both fixed velocity comparison methods without requiring data-driven training or iterative tuning, reducing thermal injury by up to 52%, improving cut accuracy by up to 59%, and maintaining task completion speed. Conclusions: Closed-loop thermal feedback via ThERMO improves autonomous robotic electrosurgery by simultaneously reducing thermal injury and improving margin accuracy, reinforcing its value over fixed velocity approaches for tumor resection applications. Significance: This work advances autonomous robotic tumor resection by demonstrating that real-time closed-loop thermal feedback control can substantially reduce collateral tissue damage and improve surgical margin accuracy.
Sep 14, 2026

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 ±\pm 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.
Sep 28, 2026

AGRO-SUVIDE: Agentic Robotics for Surgical Viscoelastic Debridement

Augmented dexterity has the potential to reduce the fatigue experienced by surgeons during repetitive surgical tasks. In this paper, we propose the first AGentic RObotics framework for SUrgical VIscoelastic DEbridement (AGRO-SUVIDE), the repeated removal of small fragments attached to a viscoelastic substrate. Leveraging the self-improving and coding capability of agents, AGRO-SUVIDE adopts a modular framework. Specifically, the demonstration analysis module automatically identifies recurring skills from a single expert demonstration, using both visual and kinematic information. The construction module then builds each skill, either as a procedural model-based skill the agent codes against a scaffolded library or as a model-free policy-based skill. At runtime, the monitoring module composes the skills into a loop-style graph sized to the number of fragments it observes, then verifies pre- and post-conditions of each skill to decide whether to advance or retry. We evaluate AGRO-SUVIDE through 340 physical trials on the da Vinci Research Kit (dVRK). AGRO-SUVIDE achieves an average single-fragment removal success rate of 85%, completing consecutive three-fragment removal at 60% and at 95% with one human intervention. It further generalizes to unseen five-fragment scenarios with an average success rate of 80% for single-fragment removal. Project page: https://surgical-robotics.github.io/AGRO-SUVIDE/