cs.CVOct 31, 2026

Modeling Fat-shift for Improved Head Segmentation from MRI Scans using a Probabilistic Model

Authors: Merle Diedrichsen, Koen Van Leemput, Douglas N. Greve, Oula Puonti, Axel Thielscher

Organizations: Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark · Department of Neuroscience and Biomedical Engineering, Aalto University, Aalto, Finland · Department of Computer Science, Aalto University, Aalto, Finland · Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, USA · 

Abstract

Personalized computational head models for biophysical simulations rely on accurate whole-head segmentations from T1-weighted (T1w) magnetic resonance imaging (MRI) scans. While T1w scans provide excellent contrast for intracranial anatomy, extracerebral tissues have partly almost no signal (compact bone) and also suffer from the so-called chemical shift artifact, which affects the fatty tissues in MRI and causes them to spatially shift in the frequency encoding direction of the scan. This artifact occurs primarily in two structures of the head: the spongy bone, a fatty compartment inside the compact bone, and the subcutaneous fat, located directly underneath the skin. The frequency-encoding direction is often set in the superior-inferior direction, causing the fatty tissues to shift down and, as a result, making the skull appear thinner than it actually is. Existing segmentation methods do not model this artifact, consequently leading to inaccurate labeling of the skull and scalp, which introduces a bias in biophysical simulations. The direction and magnitude of the fat-shift can be determined from the scan parameters, thus making it possible to explicitly model the shift and to recover the correct anatomy. This study introduces a probabilistic model that uses variational inference to segment head and brain structures from a T1w scan while accounting for the fat-shift artifact. The proposed Fat-shift-informed Label Optimization of the Whole head (FLOW) method reconstructs extracerebral anatomy more accurately than a fat-shift-agnostic segmentation approach while maintaining high segmentation accuracy in all other structures. FLOW-based fat-shift corrected segmentations significantly reduce bias in electric field simulations compared to a segmentation method that does not model the shift.

Figures & tables

Explore similar work

May 17, 2026

VISTA: Variance-Gated Inter-Sequence Test-Time Adaptation for Multi-Sequence MRI Segmentation

Deploying multi-sequence magnetic resonance imaging (MRI) segmentation models to new clinical environments is challenging due to variations in scanners and acquisition protocols. Although existing TTA methods handle basic per-modality shifts, they often fail under a fundamental dual-shift problem, as their adaptation signals fail to capture modality-interaction shifts that disrupt inter-sequence consistency. To address this, we propose Variance-gated Inter-Sequence Test-time Adaptation (VISTA), a source-free framework that tackles modality-interaction shifts. First, we design an Inter-Sequence Intervention Generator (ISIG) that generates a set of consistency probes by swapping low-frequency spectra and entropy-localized patches across sequences, preserving anatomical semantics while challenging inter-sequence dependencies. Second, we introduce Cross-View Disagreement-Aware Pseudo Labeling (CDPL), which establishes a voxel-wise reliability metric using cross-view disagreement variance to dynamically gate self-training and enforce interventional consistency, encouraging the network to rely on robust anatomical semantics. Extensive experiments adapting from standard adult MRI (BraTS-GLI-Pre) to African low-field (BraTS-SSA) and pediatric (BraTS-PED) cohorts show improved performance over competing methods under clinical shifts, achieving absolute Dice improvements of +1.89% (SSA) and +2.82% (PED) over the source model. The code is available at https://github.com/dzp2095/VISTA.
Sep 27, 2025

Confidence-Calibrating Regularization for Robust Brain MRI Segmentation Under Domain Shift

The Segment Anything Model (SAM) exhibits strong zero-shot performance on natural images but suffers from domain shift and overconfidence when applied to medical volumes. We propose CalSAM, a lightweight adaptation framework that (i) reduces encoder sensitivity to domain shift via a Feature Fisher Information Penalty (FIP) computed on 3D feature maps and (ii) penalizes overconfident voxel-wise errors through a Confidence Misalignment Penalty (CMP). The combined loss, LCalSAM\mathcal{L}_{\mathrm{CalSAM}} fine-tunes only the mask decoder while keeping SAM's encoders frozen. On cross-center and scanner-shift evaluations, CalSAM substantially improves accuracy and calibration: e.g., on the BraTS scanner split (Siemens→\toGE) CalSAM shows a +7.4%+7.4\% relative improvement in DSC\mathrm{DSC} (80.1% vs.\ 74.6%), a −26.9%-26.9\% reduction in HD95\mathrm{HD95} (4.6 mm vs.\ 6.3 mm), and a −39.5%-39.5\% reduction in ECE\mathrm{ECE} (5.2% vs.\ 8.6%). On ATLAS-C (motion corruptions), CalSAM achieves a +5.3%+5.3\% relative improvement in DSC\mathrm{DSC} (75.9%) and a −32.6%-32.6\% reduction in ECE\mathrm{ECE} (5.8%). Ablations show FIP and CMP contribute complementary gains (p<0.01p<0.01), and the Fisher penalty incurs a modest ∼\sim15% training-time overhead. CalSAM therefore delivers improved domain generalization and better-calibrated uncertainty estimates for brain MRI segmentation, while retaining the computational benefits of freezing SAM's encoder.
May 4, 2026

SIAM: Head and Brain MRI Segmentation from Few High-Quality Templates via Synthetic Training

Synthetic training has recently advanced brain MRI segmentation by enabling contrast-agnostic models trained entirely on generated data. However, most existing approaches rely on hundreds of automatically labeled templates, introducing systematic biases and limiting their flexibility to incorporate new anatomical structures. We present the Segment It All Model (SIAM), a 3D whole-head segmentation framework for 16 anatomical structures, trained using only six high-quality, manually annotated templates. SIAM extends domain randomization to both intensity and shape domains: synthetic image generation ensures contrast variability, while high-resolution spatial transformations model anatomical differences in cortical thickness and deep nuclei morphology. Unlike prior synthetic models, SIAM simultaneously segments brain as well as extra-cerebral tissues, including cerebrospinal fluid, vessels, dura mater, skull, and skin, enabling fully automated, preprocessing-free analysis. Evaluation across eight heterogeneous datasets (N=301), that include multiple contrasts (T1-weighted, T2-weighted, CT) and span a wide range of ages, demonstrates that SIAM matches or outperforms state-of-the-art methods for brain structures, in addition to extending automated segmentation to non-brain structures. The model also exhibits superior consistency across contrasts and repeated acquisitions, together with improved sensitivity to subtle gray matter atrophy. We openly release the model and the label templates at https://github.com/romainVala/SIAM.