cs.LGNov 2, 2026

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

Authors: Gerda de Jager, Marelie H Davel, Ian Thomson

Organizations: Faculty of Engineering, North-West University, Potchefstroom, South Africa · Centre for Artificial Intelligence Research, South Africa · National Institute for Theoretical and Computational Sciences, South Africa

Abstract

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

Figures & tables

Appendix figures & tables2 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 24, 2026

Decoding High-Dimensional Finger Motion from EMG Using Riemannian Features and RNNs

Continuous estimation of high-dimensional finger kinematics from forearm surface electromyography (EMG) could enable natural control for hand prostheses, AR/XR interfaces, and teleoperation. However, the complexity of human hand gestures and the entanglement of forearm muscles make accurate recognition intrinsically challenging. Existing approaches typically reduce task complexity by relying on classification-based machine learning, limiting the controllable degrees of freedom and compromising on natural interaction. We present an end-to-end framework for continuous EMG-to-kinematics regression using only consumer-grade hardware. The framework combines an 8-channel EMG armband, a single webcam, and an automatic synchronization procedure, enabling the collection of the EMG Finger-Kinematics dataset (EMG-FK), a 10-h dataset of synchronized EMG and 15 finger joint angles from 20 participants performing rich, unconstrained right-hand motions. We also introduce the Temporal Riemannian Regressor (TRR), a lightweight GRU-based model that uses sequences of multi-band Riemannian covariance features to decode finger motion. Across EMG-FK and the public emg2pose benchmark, TRR outperforms state-of-the-art methods in both intra- and cross-subject evaluation. On EMG-FK, it reaches an average absolute error of 9.79°±1.489.79 °\pm 1.48 in intra-subject and 16.71°±3.9716.71 °\pm 3.97 in cross-subject. Finally, we demonstrate real-time deployment on a Raspberry Pi 5 and intuitive control of a robotic hand; TRR runs at nearly 10 predictions/s and is roughly an order of magnitude faster than state-of-the-art approaches. Together, these contributions lower the barrier to reproducible, real-time EMG-based decoding of high-dimensional finger motion, and pave the way toward more natural and intuitive control of embedded EMG-based systems.
Nov 23, 2024

Development of a Low-Cost Prosthetic Hand Using Electromyography and Machine Learning

Electromyography (EMG) is a measure of muscular electrical activity and is used in many clinical/biomedical disciplines and modern human computer interaction. Myo-electric prosthetics analyze and classify the electrical signals recorded from the residual limb. The classified output is then used to control the position of motors in a robotic hand and a movement is produced. The aim of this project is to develop a low-cost and effective myo-electric prosthetic hand that would meet the needs of amputees in developing countries. The proposed prosthetic hand should be able to accurately classify five different patterns (gestures) using EMG recordings from three muscles and control a robotic hand accordingly. The robotic hand is composed of two servo motors allowing for two degrees of freedom. After establishing an efficient signal acquisition and amplification system, EMG signals were thoroughly analyzed in the frequency and time domains. Features were extracted from both domains and a shallow neural network was trained on the two sets of data. Results yielded an average classification accuracy of 94.8% and 93.2% for the time and frequency domains respectively. Furthermore, results showed a faster computation and response for the time domain analysis; hence, it was adopted for the classification system. A wrist rotation mechanism was designed and tested to add significant functionality to the prosthetic. The mechanism is controlled by two of the five gestures, one for each direction. Which added a third degree of freedom to the overall design. Finally, a tactile sensory feedback system which uses force sensors and vibration motors was developed to enable sensation of the force inflicted on the hand for the user.
May 20, 2026

Unsupervised clustering and classification of upper limb EMG signals during functional movements: a data-driven

This study presents a comprehensive approach for the clustering and classification of upper-limb surface electromyography (sEMG) signals during functional reach and grasp movements. The methodology was applied to the NINAPRO DB4 dataset, which provides multichannel EMG recordings of 52 gestures. A four-stage pipeline was designed, including signal preprocessing, fea-ture extraction, gesture selection via hierarchical clustering, and comparative model evaluation. Preprocessing involved a fourth-order low-pass filter (0.6 Hz) and Hilbert envelope transformation, effectively reducing noise and enhancing signal clarity. Feature extraction yielded 26 temporal and frequency-domain met-rics, which were later refined using visual analysis, mutual information, principal component analysis, and decision tree importance scores. A final subset of five key features was selected for classification tasks. Gesture selection was per-formed through hierarchical clustering using Mahalanobis distance, resulting in six representative movements that balanced biomechanical diversity and compu-tational efficiency. A 200 ms window was identified as optimal for temporal seg-mentation based on stability and physiological plausibility. Classifier models were evaluated in two stages. Automated comparison using PyCaret identified Extra Trees (ET) and Artificial Neural Networks (ANN) as top performers. Sub-sequent independent training confirmed their stability and generalization capac-ity, with ANN showing progressive learning and ET maintaining robust, con-sistent results. The findings support the implementation of adaptive, low-latency control strategies for myoelectric prostheses and provide a scalable pipeline for future real-time applications.