Impact of Input Resolution in Mammographic Mass Detection: A Controlled Multi-Architecture Study

Authors: Kaan Buyukdemirci, Emine Ulku Saritas

Organizations: Department of Electrical and Electronics Engineering, Bilkent University, Ankara 06800, Turkey · National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara 06800, Turkey

Abstract

Deep-learning-based mass detectors usually downsample mammograms, trading fine image detail for lower computational cost. However, published studies cannot reveal how much accuracy this trade-off sacrifices, since they also differ in architecture, preprocessing, and evaluation protocol. In this work, we isolated the effect of input resolution in a controlled study on the VinDr-Mammo dataset, training 18 detectors at six input resolutions ranging from 512 x 416 to 1600 x 1280 pixels, for 108 model-resolution combinations. Whole mammograms were resized without cropping or tiling. For each model, preprocessing, model initialization, augmentation, and evaluation procedures were kept fixed across resolutions. Detection accuracy was evaluated by mAP50 on the 219 mass-positive images of the official test split, and 57 combinations with test mAP50 of at least 0.60 were analyzed. From the lowest to the highest resolution, median mAP50 rose from 0.626 to 0.660 and the best mAP50 from 0.670 to 0.709. The best result, achieved by DINO with a ConvNeXt-S backbone, is the highest mAP50 reported to date on mass-positive VinDr-Mammo images. Gains were concentrated in small masses: for the smallest third of lesions, median mAP50 rose by 0.074 (from 0.367 to 0.441), compared with 0.007 and 0.032 for medium and large masses. Median training time increased from 0.45 to 1.40 h, and median inference time from 23.6 to 113.7 ms per image. Therefore, higher input resolution mainly benefits the small masses that are hardest to detect, at a computational cost that remains practical.

Figures & tables

Explore similar work

Aug 10, 2026

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% [email protected], and 74.38% [email protected]. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% [email protected], and 77.32% [email protected]. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.
Oct 1, 2026

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.
Jul 9, 2026

Multi-Resolution Feature Stem for Diabetic Retinopathy lesion segmentation

Diabetic Retinopathy (DR) is a leading cause of preventable blindness worldwide, requiring automated lesion segmentation using deep learning models for early detection and monitoring. However, DR lesions vary dramatically in size from tiny microaneurysms to large hemorrhages and exudates. This variability creates conflicting demands on the model architecture and input resolution, posing a challenge for effective design. This work investigates the impact of input resolution on different lesion types. Through systematic experimentation with multiple architectures (U-Net, UNet++, Vision Transformers, DeepLabV3+) at 512×512512 \times 512 and 1024×10241024 \times 1024 resolutions, we identify a critical, counter-intuitive phenomenon where increasing input resolution has opposing effects on different lesion types. We demonstrate that while higher resolution is essential for resolving fine-grained microaneurysms, it can unexpectedly degrade performance on larger hemorrhages. This finding challenges the common assumption that higher resolution is uniformly beneficial. To address this, we propose a novel Multi-Resolution Feature Stem, an input-level pyramid integrated with a UNet++ backbone. This architecture processes multiple scales in parallel, capturing fine-grained details without sacrificing contextual information. This work contributes crucial empirical evidence of this complex, resolution-dependent behavior and a practical, parameter-efficient architecture that successfully resolves this trade-off.