Authors: Yoon Pyo Lee, Samrendra Roy, Jay Phil Yoo, Kazuma Kobayashi, Souvik Chakraborty, Syed Bahauddin Alam
Organizations: Department of Nuclear, Plasma, and Radiological Engineering, The Grainger College of Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA. · Department of Applied Mechanics, Indian Institute of Technology Delhi, New Delhi, India. · Yardi School of Artificial Intelligence, Indian Institute of Technology Delhi, New Delhi, India. · National Center for Supercomputing Applications, University of Illinois Urbana-Champaign, Urbana, IL, USA.
Planning electricity systems requires repeated decisions that connect regional resources, investment, operation and network constraints. Here we present an autonomous planning framework that carries prepared regional scenarios through proposal, numerical evaluation, feedback interpretation, redesign and final plan selection. Agents propose investment bounds, storage operating conditions and feeder interventions, interpret numerical feedback, and decide how to revise designs and when to stop. The framework automatically executes annual investment-and-dispatch optimization and representative-feeder verification, applies fixed acceptance criteria and retains the lowest-cost accepted candidate. We evaluate forty carbon-constrained trajectories across ten system-year scenarios in five electricity systems and four countries, using two model deployments and single- and multi-agent architectures. All forty retain candidates satisfying the implemented physical and fixed annual operational carbon-budget checks. Twenty-eight of forty matched reference designs exceed the new scenario ceilings. A separate archive of ninety-six trajectories under a common 1,000 Mt annual ceiling provides matched references and broader regional coverage. The results demonstrate autonomous planning under explicit emissions constraints using public regional data and published institutional demand outlooks.
Figures & tables
Study
Planning decision addressed
Scope demonstrated
Electricity-system studies in Nature Energy
Zhu et al. [ 5 ]
How much generating capacity is needed to meet global electricity needs under net-zero pathways?
Joint capacity expansion and hourly operation in a spatially resolved global model.
Few et al. [ 6 ]
Where can local flexibility reduce network upgrades?
Network simulations quantify how upgrade costs and the value of flexibility vary across Great Britain.
Beiter et al. [ 10 ]
How much offshore wind is built under different planning assumptions?
US expansion scenarios quantify deployment across cost, transmission and policy assumptions.
Senga et al. [ 11 ]
Where should interregional transmission expand?
US expansion strategies are compared on cost, emissions and reliability during extreme events.
Liang et al. [ 12 ]
Where does heat limit grid capacity?
Weather-dependent demand and equipment limits reveal transmission bottlenecks in western Europe.
Table 1: Planning decisions and scope of electricity-system studies and agent-assisted distribution planning.
Figure 1: Reality-grounded planning as an adaptive experimental loop. The broader input library covers eight systems and 58 model zones. Regional records, inherited assets, network assumptions, costs and demand outlooks define scenarios. ERA5 supplies 2023 weather; NASA projections for 2030 and 2035 are reconstructed with ERA5 intraday templates. PySAM and a turbine curve produce power profiles. Agents propose design bounds through a single conversation with strategy notes or a ten-role specialist team. Specialists propose, an orchestrator commits one experiment, and reviewers evaluate, critique, refine a procedure graph, compress memory and judge convergence. PyPSA optimizes investment and annual dispatch; OpenDSS screens representative feeders. Evidence returns to guide subsequent experiments, while a separate record retains the lowest-cost accepted committed candidate. In the primary evaluation, PyPSA also enforces an immutable annual operational CO 2 budget. The ERCOT traces and schematic, regional 2035 additions and 96-trajectory count illustrate the loose-cap reference evaluation under the original 1,000 Mt ceiling (Tables 11 and 7.2 ). Regional bars select the lowest observed accepted cost across four reference trajectories per system. Black denotes inherited assets and output; colours identify added technologies. Connections have model-zone resolution and the feeder is schematic. Primary carbon-constrained outcomes are reported in Fig. 2 . The basemap uses Natural Earth [ 22 ] .
Figure 2: Complete outcomes under annual operational carbon budgets. The ten system–year scenarios each contain two model deployments and two agent architectures. All forty retained outcomes satisfy the implemented physical and carbon-budget checks. Selected annual cost includes representative-distribution interventions. Emissions are direct operational CO 2 expressed relative to the corresponding scenario budget. A budget ratio of one denotes an outcome at the ceiling within numerical tolerance. The budgets are research constraints adopted from sources with the distinctions listed in Table 5 .
Figure 3: Optimized grid additions and operational carbon emissions. Paired maps show the minimum observed accepted-cost design for each system’s latest evaluated year. GPT-6.1 Sol single-agent supplies all representatives; tied minima and years are marked. Pie colours distinguish technology additions; grey and magenta links show existing connections and selected transfer increments. Fixed-size emission circles use a shared logarithmic colour scale; hollow circles denote zero. Each row reports annual cost, direct operational CO 2 , the whole-system budget and its source. Budget values and source-to-model mappings are in Table 5 . Emissions are modelled from retained dispatch and declared inventory factors. Locations represent model zones. The ten-case atlas retains all years. The basemap uses Natural Earth [ 22 ] .
Figure 4: Minimum observed accepted portfolios under carbon budgets. Each system–year scenario shows the portfolio with the lowest observed all-in annual cost among its four accepted trajectories. Six scenarios have a unique observed minimum and four have tied minima within a USD 10 annual-cost tolerance. Panels a–c display the GPT-6.1 Sol single-agent representative, while panel d lists every deployment–architecture configuration attaining the observed minimum within this tolerance. Generation and storage values describe additions to the inherited fleet, with battery power and energy distinguished. Selection is conditional on the system, representative-feeder and carbon-budget checks. The complete comparisons retain all forty trajectories and their numerical bounds.
System
Capacity
Expert plan
Carbon range
Difference
Brazil
Wind
49.55
120.19
+70.64
Brazil
Solar †
29.19
96.66
+67.47
Brazil
Battery power
6.63
0.00
-6.63
South Africa
Wind
26.39
5.57–6.24
[−20.82,−20.14]
South Africa
Solar †
21.16
63.02–64.24
[+41.86,+43.08]
Table 2: Published plans and carbon-constrained portfolios in 2035. Values are total capacities in GW, including inherited assets. Carbon ranges span all four retained accepted deployment–architecture trajectories per system. Differences are carbon-constrained agent values minus the published plan, calculated before rounding. Brazil and South Africa use annual model budgets of 29 and 142 MtCO 2 , respectively.
Figure 5: Recorded effort in the carbon-constrained planning searches. Logical system-evaluation requests, received API responses and provider-reported tokens describe different components of search effort. The forty trajectories contain 202 logical system-evaluation requests and 764 recorded received responses, with 90.562 million input tokens and 1.314 million output tokens. Logical requests include exact-result reuse and therefore are not counts of newly executed numerical optimizations. Recovery histories and the recorded reuse revision are retained in the evidence. These summaries do not constitute a wall-runtime or scaling benchmark.
AEMO five-minute regional TOTALDEMAND from price-and-demand records, averaged to hourly
New Zealand
5
EMI metered grid offtake by point of connection, summed to the five EMI zones
Table 3: Selected evaluation systems. Counts describe demand aggregation units within each coupled system. All reported trajectories use brownfield mode. The common base demand year is 2023, with different source types retained explicitly.
System
Corridors
Network basis
Candidate projects
NYISO
12
Directional transfer limits; five model cut-sets assembled from operating and reliability studies
Propel NY (1,300 MW into Zone K)
MISO
7
Zonal import/export limits; Midwest–South physical transfer limits 3,000/2,500 MW
LRTP Tranche 1 and 2.1 lines, segments of one project bundled
ERCOT
17
Fixed study limits of 12,240 MW for West Texas Export and 5,595 MW for North-to-Houston
Permian 765 kV import paths and STEP eastern backbone; aggregate STEP increment assigned as described below
South Africa
21
NTCSA line GIS aggregated to supply areas; ratings estimated using the PyPSA-RSA method [ 39 , 40 ]
31 inter-area candidates extracted from the TDP
Australia
5
Static directional capabilities from AEMO’s archived September 2025 edition (v5)
VNI West, QNI Connect, Marinus Link stages 1/2 and EnergyConnect; ISP Appendix 5
New Zealand
4
HVDC inter-island capability from the Transmission Planning Report 2023; island backbones as non-binding proxies
HVDC cable replacement and possible fourth-cable upgrade to 1,400 MW northward
Table 4: Zonal transmission networks in the evaluation package. Public records supply topology, interface limits and project descriptions. Corridor aggregation, estimated ratings, non-binding proxies and assigned project increments are modelling choices recorded in the input manifests.
System
Year
Budget (Mt yr -1 )
Source basis
NYISO
2023
24.761865
New York RGGI base allowance budget
NYISO
2030
12.425308
New York RGGI base allowance budget
NYISO
2035
3.550088
New York RGGI base allowance budget
MISO
2030
200.033343
Future 2 aggregate planning constraint
MISO
2035
164.641838
Future 2 aggregate planning constraint
South Africa
2030
168
IRP 2025 balanced-plan emissions pathway
Table 5: Annual operational CO 2 budgets in the primary evaluation. Each scenario contains both deployments and both architectures. Displayed values are rounded; the archive retains exact source values and conversions. The source categories are retained because an allowance budget, a planning-model constraint and a projected emissions outcome have different institutional meanings. Mexico and Brazil use published CO 2 -equivalent values as numerical proxies for direct operational CO 2 .
System
Demand 2023
Demand 2030
Change (%)
Demand 2035
Change (%)
MISO
640.968
868.579
35.5
961.187
50.0
ERCOT
446.802
983.792
120.2
1136.972
154.5
NYISO
146.997
160.160
9.0
170.170
15.8
South Africa
227.005
257.571
13.5
294.539
29.7
Australia
180.155
203.655
13.0
252.242
40.0
New Zealand
37.630
44.919
19.4
51.399
36.6
Table 6: Annual electricity demand in the year-matched inputs. The 2023 demand is paired with ERA5 2023 weather; 2030 and 2035 demand are paired with the corresponding NASA-derived weather. Energy is in TWh; changes are relative to 2023. Both architectures share each input. South African values are spatialized model outputs, Australian growth is mapped between consumption definitions, and New Zealand uses an island winter-growth annualization.
Wind
Solar PV
System
2023
2030
2035
2023
2030
2035
MISO
0.321
0.255
0.271
0.168
0.202
0.204
ERCOT
0.339
0.256
0.245
0.179
0.211
0.210
NYISO
0.230
0.422
0.441
0.149
0.184
0.189
South Africa
0.252
0.228
0.218
0.201
0.205
0.206
Australia (NEM)
0.249
0.439
0.449
0.170
0.180
0.180
Table 7: Mean resource capacity factors in the reported input packs. Values are unweighted means of annual node capacity factors in each system. The 2023 packs use ERA5; the 2030 and 2035 packs use NASA NEX-GDDP-CMIP6 fields reconstructed as described above.
Demand year
Weather source
Hourly template
Hourly index
2023
ERA5 2023 reanalysis
2023
2023
2030
NASA MPI-ESM1-2-HR SSP2-4.5, 2030 projection
ERA5 2023
2023
2035
NASA MPI-ESM1-2-HR SSP2-4.5, 2035 projection
ERA5 2023
2023
Table 8: Weather inputs and time coordinates. Future resource profiles combine the indicated NASA daily projection with ERA5 2023 intraday patterns. Each row covers eight systems and 58 nodes; every profile contains 8,760 hours. The two future rows comprise 16 prepared input packs and 116 annual profiles.
Appendix figures & tables22 assets
Supplementary material from the paper’s appendix.
Appendix
Figure 1: Carbon-constrained outcomes and matched loose-cap references. Comparisons pair each primary trajectory with the archived trajectory having the same system, year, deployment and architecture under the original 1,000 Mt annual ceiling. Twenty-eight reference designs exceed the source-derived ceilings. Costs include annualized representative-feeder interventions, and emissions are direct operational CO 2 within the model boundary. Open triangles identify the two 2023 Opus pairs with distinct output ceilings and provider configurations. The points describe observed trajectories and are not repeated samples.
Figure 2: Candidate-specific numerical bounds for the selected carbon-constrained outcomes. Each interval spans the numerical solver lower bound and achieved system objective for the selected candidate’s fixed optimization domain, adding the selected distribution cost at both endpoints. These intervals describe numerical uncertainty within each candidate-specific problem. They are not confidence intervals or bounds on the full agent search space. All forty selected outcomes pass the physical and carbon-budget checks.
Setting
Claude Opus 5.5
Inference
Anthropic Messages API
Completed trajectories
16 for demand year 2023
Single-agent ceiling
120 turns; 40 committed evaluations
Multi-agent ceiling
120 cycles
Default output ceiling
16,000 tokens
Generation
Adaptive thinking; high effort; standard-only tier
Appendix
Table 9: Execution settings for the sixteen reported Opus baseline trajectories. Evaluation counts include requests served by an exact matching cached result.
Model
Demand and weather inputs
Completed cases
GPT-6.1 Sol
2023 demand with ERA5 2023 weather; 2030 and 2035 demand with the corresponding NASA-derived weather
48
Claude Opus 5.5
2030 and 2035 demand with the corresponding NASA-derived weather
32
Appendix
Table 10: Completed cases in the new hosted weather campaign. Each listed demand year contains eight systems and two agent architectures. The sixteen earlier Opus base-year trajectories are reported separately.
Deployment
Demand / weather
Single
Multi
Accepted
Total
GPT-6.1 Sol
2023 / ERA5
8
8
16
16
GPT-6.1 Sol
2030 / NASA
8
8
16
16
GPT-6.1 Sol
2035 / NASA
8
8
16
16
Opus 5.5
2023 / ERA5
8
8
16
16
Opus 5.5
2030 / NASA
8
8
16
16
Opus 5.5
2035 / NASA
8
8
16
16
Appendix
Table 11: Loose-cap reference coverage and physical acceptance. Each cohort contains eight systems and both architectures. The complete GPT-6.1 Sol–Opus grid contains 96 trajectories. Accepted counts refer to trajectories with a retained committed candidate passing the implemented system and representative-feeder gate. Baseline resources are ERA5 2023; future resources are reconstructed for the indicated NASA projection year.
Figure 1: Lowest-cost accepted regional designs for 2035. a–h, Minimum accepted annual costs among four trajectories per system (billion USD). Power bars share a 0–100 GW scale; sector area encodes added generation and battery power. Colours identify technologies; hollow points mark additions below 0.005 GW. Black points locate US plants; black corridors are existing, dashed for assumed ratings. Magenta widths encode added transfer capacity. New allocations and straight corridors have model-zone resolution. All 96 outcomes remain tabulated; Appendix 9 gives zonal amounts. The basemap uses Natural Earth [ 22 ] .
Figure 2: ERCOT allocation and representative-feeder repair in an Opus multi-agent trajectory. This process example is distinct from the lower-cost Sol ERCOT design in Fig. 1 and Appendix 9 . a, New generation and battery power at numbered model zones, with the same technology colour key. b, Initial and selected Far West three-bus numerical circuits; line ratings increase from 400 to 600 A and impedances are halved under the intervention model. Line colours and percentages use annual peak current divided by each line’s own rating. Annual voltage ranges are shown separately; extrema can occur at different hours. c, Selected additions and battery energy; no new inter-area transfer is selected. d, Recorded violation hours, accepted feeder count and annualized intervention cost (million USD per year). All eight selected representative feeders pass. The selected design combines feeder reinforcement with a revised portfolio and dispatch.
System
Selected cost
System evaluations
Model requests
MISO
28.293256/28.293256
1/3
3/11
ERCOT
18.225239/18.225239
3/3
6/11
NYISO
8.030121/8.030121
2/3
5/21
South Africa
10.652093/10.656181
8/13
11/55
Australia
7.052820/7.052820
3/3
7/11
New Zealand
0.569150/0.569150
1/3
4/11
Appendix
Table 12: Claude Opus 5.5 planning with 2023 demand and ERA5 2023 weather. Entries are single/multi. Selected costs are billion USD per year, including representative-distribution interventions. System evaluations count committed and uncommitted verification requests, including exact-result reuse; model requests count unique received responses in the selected trajectory ledger.
Figure H1: Two deployments under 2023 demand and ERA5 2023 weather. a, System-evaluation requests across 32 trajectories, comprising committed simulations and hypothetical verifications, including exact-result reuse. Cell values are exact and colour uses one linear scale. b–d, Selected all-in annual costs in NYISO, South Africa and Mexico on panel-specific scales. Filled circles denote single-agent and open squares multi-agent trajectories. Blue denotes GPT-6.1 Sol and orange Claude Opus 5.5. Horizontal intervals extend from the candidate’s solver lower bound plus its distribution cost to its selected total cost; the magnified axes condition on each selected design.
System
GPT-6.1 Sol
Claude Opus 5.5
MISO
46.000616/46.145542
46.003694/46.003694
ERCOT
68.057741/68.076200
68.407019/68.407550
NYISO
6.477653/6.477653
6.477653/6.477653
South Africa
12.017688/12.019324
12.052166/12.020040
Australia
6.861099/6.861099
6.861099/6.861099
New Zealand
0.646734/0.646734
0.646734/0.646734
Appendix
Table 13: Selected annual cost under 2030 demand and NASA-derived 2030 weather. Entries are single/multi, in billion USD per year including annualized representative-distribution interventions. Each cell is one trajectory; candidate-specific solver intervals are retained in the comparison evidence.
System
GPT-6.1 Sol
Claude Opus 5.5
MISO
52.959760/53.216539
52.961390/53.216539
ERCOT
82.980096/82.957622
83.762708/83.150660
NYISO
6.829947/6.829947
6.829947/6.829947
South Africa
14.097805/14.098005
14.202359/14.101251
Australia
8.853329/8.854495
8.854495/8.854495
New Zealand
0.799669/0.799669
0.799669/0.799669
Appendix
Table 14: Selected annual cost under 2035 demand and NASA-derived 2035 weather. Entries are single/multi, in billion USD per year including annualized representative-distribution interventions. Each cell is one trajectory; candidate-specific solver intervals are retained in the comparison evidence.
Deployment/year
Committed
Verify
Responses
Median cycles
Sol 6.1 2023
62
29
398
1
Sol 6.1 2030
91
50
578
1
Sol 6.1 2035
91
53
517
1
Opus 5.5 2030
41
29
254
1
Opus 5.5 2035
46
41
290
1
Appendix
Table 15: Evaluation effort in the completed eighty-trajectory hosted campaign. Each row contains sixteen trajectories. Evaluations are logical requests, including exact-result reuse, rather than physical optimizer invocations. The 2023 control row uses ERA5 2023 weather; the future rows use the corresponding NASA-derived weather.
System
Selected cost
Evaluations
Responses
MISO
28.293256/28.293256
3/3
9/12
ERCOT
18.225239/18.225239
3/3
9/11
NYISO
8.030084/8.030121
4/4
14/21
South Africa
10.647249/10.647689
7/25
23/149
Australia
7.052820/7.052820
4/3
12/11
New Zealand
0.569150/0.569150
3/3
9/11
Appendix
Table 16: GPT-6.1 Sol controls with 2023 demand and ERA5 2023 weather. Entries are single/multi. Selected costs are billion USD per year including distribution interventions; evaluations include committed and hypothetical requests.
Figure H2: Selected-cost comparisons with NASA-derived future weather. a,b, Multi minus single selected annual cost, as a percentage of the single-agent cost, for GPT-6.1 Sol and Claude Opus 5.5 under 2030 and 2035 demand and weather. c,d, Opus minus Sol selected annual cost as a percentage of the Sol cost, for the two architectures. Intervals extend from the first candidate’s solver lower bound minus the second candidate’s achieved cost to the first candidate’s achieved cost minus the second candidate’s lower bound. Each candidate’s distribution cost is included at both endpoints. The intervals describe numerical bounds conditional on the two selected design domains. Negative values favour multi in a,b and Opus in c,d. Each point represents one matched pair.
Figure I1: Lowest-cost accepted 2035 design for MISO. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is GPT-6.1 Sol, single-agent, at USD 52.960 billion per year. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. Additional transfer capacity is 1.00 GW on 0035–8910. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I2: Lowest-cost accepted 2035 design for ERCOT. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is GPT-6.1 Sol, multi-agent, at USD 82.958 billion per year. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. No additional transfer capacity is selected. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I3: Lowest-cost accepted 2035 design for NYISO. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is Claude Opus 5.5, multi-agent, at USD 6.830 billion per year. All four trajectories have the same reported minimum cost; this portfolio is a stable representative of the tie. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. Additional transfer capacity is 1.00 GW on ZONB–ZONC, 1.00 GW on ZONE–ZONF, 1.00 GW on ZONI–ZONJ and 1.00 GW on ZONI–ZONK. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I4: Lowest-cost accepted 2035 design for South Africa. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is GPT-6.1 Sol, single-agent, at USD 14.098 billion per year. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. Additional transfer capacity is 1.20 GW on HYDRA–WC. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I5: Lowest-cost accepted 2035 design for Australia (NEM). Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is GPT-6.1 Sol, single-agent, at USD 8.853 billion per year. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. Additional transfer capacity is 1.26 GW on NSW1–QLD1, 2.55 GW on VIC1–TAS1 and 0.80 GW on NSW1–SA1. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I6: Lowest-cost accepted 2035 design for New Zealand. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is Claude Opus 5.5, multi-agent, at USD 0.800 billion per year. All four trajectories have the same reported minimum cost; this portfolio is a stable representative of the tie. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. No additional transfer capacity is selected. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I7: Lowest-cost accepted 2035 design for Mexico. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is GPT-6.1 Sol, single-agent, at USD 26.409 billion per year. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. No additional transfer capacity is selected. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Figure I8: Lowest-cost accepted 2035 design for Brazil. Lowest observed selected total annual cost among four physically accepted trajectories using identical 2035 demand and NASA resource inputs. The displayed portfolio is Claude Opus 5.5, multi-agent, at USD 33.736 billion per year. All four trajectories have the same reported minimum cost; this portfolio is a stable representative of the tie. Map symbols follow Fig. 1 ; numbers link to the zonal ledger. Existing is inherited generation; Energy is added battery energy; dashes are below 0.005 in the displayed units. No additional transfer capacity is selected. All represented feeder checks pass. Locations and corridors have model-zone resolution. The basemap uses Natural Earth.
Department of Computer Applications in Science and Engineering, BARCELONA Supercomputing Center, Barcelona, Spain · Escuela T´ecnica Superior de Ingenier´ıa (ICAI), Universidad Pontificia Comillas, Madrid, Spain · Human-Centered AI, Data and Software, LUXEMBOURG Institute of Science and Technology, Esch-sur-Alzette, Luxembourg