cs.CVNov 4, 2026

LungMend: A Healthy-Only Latent Diffusion Shape Prior for Lung Mask Correction in Severe Tuberculosis CT

Authors: Rezkellah Noureddine Khiat, Pierre-Yves Brillet, Catalin Fetita

Organizations: SAMOVAR, Télécom SudParis, Institut Polytechnique de Paris, Palaiseau, France · Avicenne Hospital, AP-HP, Bobigny, France

Abstract

Lung segmentation models such as R231 are widely used, but they fail on severe tuberculosis (TB) CT: cavities and consolidations look like non-lung tissue and are left out of the mask. We present LungMend, a post-processing model that corrects such masks using only healthy anatomy. A latent diffusion model, trained on healthy lungs with synthetically corrupted masks, learns to recover the complete lung from the faulty mask and the bone anatomy, without any pathological data or CT intensities. LungMend recovers cavities and consolidations that R231 misses and improves accuracy on expert-annotated slices. Code: https://github.com/noureddinekhiati/LungMend

Figures & tables

Explore similar work

Jul 7, 2026

TMF-RSE: Tri-Modal Fusion with Regional Semantics and Evidential Uncertainty for Lung Severity Scoring

Accurate quantification of lung disease severity from chest imaging is critical for clinical decision-making and resource allocation. We propose a tri-modal deep learning framework, TMF-RSE (Tri-Modal Fusion with Regional Semantics and Evidential Uncertainty), that combines appearance features from two-dimensional chest inputs, structural features from lung segmentation masks, and semantic features from vision-language models (VLMs) for severity quantification. Our approach employs complementary fusion mechanisms that integrate semantic guidance, structural priors, and hierarchical interactions across modalities. The model employs evidential regression to provide both severity predictions and uncertainty estimates. Experiments on the Per-COVID-19 CT and RALO datasets show that TMF-RSE outperforms recent transformer-based baselines, achieving MAE of 4.02 and Pearson correlation of 0.9629 on Per-COVID-19 validation, and 0.339 MAE / 0.973 PC on RALO geographic extent.
Oct 16, 2026

NV-Generate-Body: 3D Latent Diffusion Model forControllable Anatomy, Tumor, and Demographic Body Mask Synthesis

Curating large labeled CT datasets is expensive and constrained by patient privacy. We present NV-Generate-BodyMask, a 3D latent diffusion model that synthesizes whole-body CT segmentation masks with precise, joint control over organ anatomy, tumor burden, and patient demographics. The model operates in the compressed latent space of a frozen mask autoencoder, generating 2563256^3 volumetric label maps conditioned on a 19-dimensional vector via Adaptive Group Normalization and cross-attention. A size-adaptive ROI loss with spatial halo weighting and a paired tumor injection pipeline enable accurate tumor size conditioning despite the scarcity of annotated tumor cases. Trained on 8,571 masks across 26 cohorts spanning 132 labels, the model achieves Spearman ρ=0.70ρ= 0.70--0.920.92 for organ size, 85--100% tumor recall for lung, pancreatic, colon, and bone lesions, and strong demographic alignment (BMI ρ=0.78ρ= 0.78, sex-conditioned perfect prostate control).
Sep 8, 2026

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.