physics.med-phNov 6, 2026

SmartBloch-Agent: An Agentic Framework for Automated MRI Sequence Design and Optimization

Authors: Jiakai Yang, Haoye Zheng, Yixiao Yue, Qinqin Yang, Zhong Chen, Shuhui Cai, Congbo Cai

Organizations: School of Electronic Science and Technology, Xiamen University, Xiamen 361005, China · Department of Radiological Sciences, University of California Irvine, Irvine, CA 92697, United States of America

Abstract

Magnetic resonance imaging (MRI) pulse sequences organize radiofrequency excitation, gradient encoding, and signal acquisition, determining magnetization evolution and image formation. Sequence research requires translating imaging objectives into executable protocols meeting physical and acquisition constraints, refined via physical simulation, signal reconstruction, and scientific evaluation. Sequence construction, physical verification, parameter search, and assessment involve many tools and manual decisions, limiting automation from objective to verifiable sequence. We develop SmartBloch-Agent, an integrated framework for automated MRI sequence design and optimization. Given objectives and scientific constraints in natural language, an AI agent interprets goals, plans tasks, orchestrates tools, and makes feedback-informed decisions, drawing on a construction module and optimizers for structural design and parameter search. Our GPU-accelerated SmartBloch engine supplies physical computation for both stages, so the framework configures, per sequence and objective, event validation, Full-Bloch magnetization evolution, signal acquisition, image reconstruction, and scientific evaluation, and closes the loop without external MRI simulators. Results return to the agent to guide sequence revision, parameter optimization, and candidate selection, and the design files carry simulation, reconstruction, and evaluation evidence, forming an output package for a real-scanner workflow. Experiments show the framework automatically designs and optimizes MRI sequences for varied objectives and constraints, refines candidates with physical feedback, and improves several parameter-estimation metrics and downstream quantitative reconstruction. SmartBloch-Agent unifies objectives, design, physical execution, and evaluation into a continuous workflow for end-to-end automation of MRI sequence research.

Figures & tables

Appendix figures & tables16 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Apr 16, 2026

Sequence Search: Automated Sequence Design using Neural Architecture Search

Developing an MR sequence is challenging and remains largely constrained by human intuition. Recently, AI-driven approaches have been proposed; however, most require an initial sequence for parameter optimization or extensive training datasets, limiting their general applicability. In this study, we propose "Sequence Search," an automated sequence design framework based on neural architecture search. The method takes tissue properties, imaging parameters, and design objectives as inputs and generates pulse sequences satisfying the design objectives, without requiring prior knowledge of conventional sequence structures. Sequence Search iteratively generates candidate sequences through neural architecture search and optimizes them via a differentiable Bloch simulator and objective-specific loss functions using gradient-based learning. The framework successfully replicated conventional spin-echo, T2-weighted spin-echo, and inversion recovery sequences. Less intuitive solutions were also discovered, such as three-RF spin-echo-like sequences with reduced RF energy and refocusing phases deviating from the conventional Hahn-echo. This work establishes a generalizable framework for automated MR sequence design, highlighting the potential to explore configurations beyond conventional designs based on human intuition.
Nov 9, 2026

MRFoundry: Knowledge-guided agent loops for end-to-end MRI research

AI agents can write code, use scientific software, and revise computational workflows, opening new possibilities for MRI research. Effective assistance requires connecting acquisition physics, data conventions, specialized tools, and scientific validation. We present MRFoundry, an open-source, extensible package that connects MRI knowledge to agent actions and output checks. Project-local memory preserves decisions and evidence, while reviewed contributions allow researchers to improve shared guidance. Researcher-supervised examples demonstrate skill-guided sequence auditing and acquired-data reconstruction, connecting tool use, output checks, and documented decisions. Alongside MRFoundry, we introduce MRI Agent Bench to compare agents with and without the package across models and MRI task domains. Across 240 paired Core evaluations spanning 24 task types and ten models, all-checks-passed completion increased from 67.5% without MRFoundry to 78.3% with it. Across 134 Hard pairs, completion increased from 36.6% to 44.8%. MRFoundry makes MRI workflow expertise available as reusable guidance that researchers can inspect, adapt, and extend within existing agent and scientific software environments. MRFoundry is openly available at https://github.com/KeWang0622/MRFoundry.
Jun 8, 2026

A multi-agent system for spine MRI report generation from multi-sequence imaging

Spinal pathology is a leading cause of pain and disability worldwide. Spine MRI is central to clinical evaluation, yet its interpretation remains complex and time-consuming, requiring integration of information across multiple imaging sequences and anatomical regions. Despite recent advances in automated MRI analysis, effectively combining multi-sequence data while preserving sequence-specific diagnostic information remains an open challenge. Here we present SpineAgent, a multi-agent framework for spine MRI report generation built upon a multi-sequence foundation model trained on routine clinical data from 32,047 patients and 453,683 MRI series, comprising a total of 13,441,191 MRI slices. To accommodate diverse modalities of sequences, we first pre-train two DINOv3-based encoders separately on T1- and T2-weighted sequences. We then introduce a continual training strategy that learns a synthesizer to embed images of other sequences using the T1 and T2 encoders, producing patient-level embedding that integrates various signals across MRI sequences. Using these embeddings, SpineAgent achieves state-of-the-art performance, and demonstrates strong generalizability under cross-manufacturer and cross-cohort evaluation. Beyond classification, SpineAgent enables pathology localization by identifying findings-relevant slices and segmenting pathological regions. It also supports multimodal image-report retrieval, providing a solid foundation for scalable and explainable MRI report generation. We further integrate these validated capabilities of SpineAgent into 37 specialized agents. Finally, we incorporate their outputs as structured tokens within a Medical Report Agent trained end-to-end for report generation. Through both automated metrics and expert evaluation by five radiologists, SpineAgent achieves leading performance in spine MRI report generation.