cs.CVNov 7, 2026

EndoSCOP-V: A Multi-Turn Video Understanding Evaluation Framework for Multimodal Models in Endoscopy Reporting and Clinical Reasoning

Authors: Abhishek Tyagi, Tanmay Jain, Vilas Biradar, Krithi Krishna Koduri, Misba Hul Bashir Masoodi, Swetha Rapolu, Hardik Rughwani, Rachana Kotha, 

Organizations: Department of Artificial Intelligence, Asian Institute of Gastroenterology, India · Department of Gastroenterology, Asian Institute of Gastroenterology, India · University of Vermont Medical Center, USA

Abstract

Endoscopic diagnosis unfolds over native video, where a single positive finding during traversal of the gastrointestinal tract sets off a multi-minute chain of reasoning over location, morphology, severity and intervention. Existing endoscopy multimodal benchmarks test only static images or single-disease videos, which miss the temporal and clinical reasoning that real-world reporting demands. We introduce EndoSCOP-V, a video-grounded multi-turn evaluation framework for structured endoscopy reporting and clinical reasoning. It contains 1,307 real-world endoscopy and colonoscopy videos (63.2 h; 97% 1080p) averaging about 174 s. Its 20,274 question-answer turns are instantiated deterministically from clinician-filled structured endoscopy-reporting EHRs, so no per-case annotation is synthetic or LLM-rephrased. They come from 1,033 clinician-reviewed templates, about 18 per disease, that span a clinically aligned 9-task x 30-sub-task reporting taxonomy over 54 World Endoscopy Organization (WEO) MST 3.0 diseases. 22% of procedures carry co-existing pathologies, up to six per case. A Markovian context-pruned oracle-forcing protocol evaluates the dialogue turn by turn, injecting the gold answer before each subsequent turn so that per-turn reasoning is isolated from cascading dialogue errors. A panel of 15 board-certified endoscopists sets a 78% strict-accuracy baseline on 1,500 questions. Across 14 open-weight LMMs, the best 27B-class model reaches 59.8% strict accuracy, falling to 53.4% once format-trivial disease-rejection items are excluded. On a between-subjects spot-check, the best of 3 frontier proprietary models trails the clinician panel by 23 pp on strict NDR accuracy. Sub-task analysis reveals consistent gaps in quantitative measurement, multi-variable grading and intervention reasoning on long-horizon video. Data: Hugging Face (EndoSCOP-V). Code: GitHub (abhi25t/EndoSCOP-V).

Figures & tables

Appendix figures & tables12 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 30, 2026

A report-grounded vision-language foundation model for colonoscopy from 280000 routine reports

Vision-language models remain underused in colonoscopy despite the rich expert descriptions recorded in routine reports. These reports document lesion appearance, size and location but summarise entire procedures rather than caption individual frames, leaving clinical findings only weakly linked to the corresponding images. Here we develop EndoCLIP, a colonoscopy vision-language foundation model trained on 125,756 lesion-level image-text pairs progressively recovered from 280,476 routine colonoscopy records. Across lesion-level image-text retrieval, structured report generation and six multi-centre clinical classification tasks, EndoCLIP outperforms general-purpose and biomedical vision-language encoders in both zero-shot and linear-probe settings. On benign-versus-malignant classification, its linear probe approaches the performance of expert readers in a blinded study involving 12 endoscopists. These results suggest that recovering finding-to-frame correspondence can transform routine documentation into scalable supervision, enabling clinical targets to be specified in language rather than separately annotated for each task.
Apr 23, 2026

Divide-then-Diagnose: Weaving Clinician-Inspired Contexts for Ultra-Long Capsule Endoscopy Videos

Capsule endoscopy (CE) enables non-invasive gastrointestinal screening, but current CE research remains largely limited to frame-level classification and detection, leaving video-level analysis underexplored. To bridge this gap, we introduce and formally define a new task, diagnosis-driven CE video summarization, which requires extracting key evidence frames that covers clinically meaningful findings and making accurate diagnoses from those evidence frames. This setting is challenging because diagnostically relevant events are extremely sparse and can be overwhelmed by tens of thousands of redundant normal frames, while individual observations are often ambiguous due to motion blur, debris, specular highlights, and rapid viewpoint changes. To facilitate research in this direction, we introduce VideoCAP, the first CE dataset with diagnosis-driven annotations derived from real clinical reports. VideoCAP comprises 240 full-length videos and provides realistic supervision for both key evidence frame extraction and diagnosis. To address this task, we further propose DiCE, a clinician-inspired framework that mirrors the standard CE reading workflow. DiCE first performs efficient candidate screening over the raw video, then uses a Context Weaver to organize candidates into coherent diagnostic contexts that preserve distinct lesion events, and an Evidence Converger to aggregate multi-frame evidence within each context into robust clip-level judgments. Experiments show that DiCE consistently outperforms state-of-the-art methods, producing concise and clinically reliable diagnostic summaries. These results highlight diagnosis-driven contextual reasoning as a promising paradigm for ultra-long CE video summarization.
Aug 10, 2025

EndoCogniAgent: Closed-Loop Agentic Reasoning with Self-Consistency Validation for Endoscopic Diagnosis

Endoscopic diagnosis is an iterative process in which clinicians acquire, compare, and verify local visual evidence before reaching a conclusion. Current AI systems do not adequately support this process because fine-grained evidence acquisition and multi-step reasoning remain weakly coupled, complicating reconciliation of image-derived findings with their textual interpretations. This gives rise to two failure modes, hallucinated evidence and uncorrected error accumulation, that undermine diagnostic reliability. We propose EndoCogniAgent, a closed-loop agentic framework that formulates endoscopic diagnosis as a controlled state update process for integrating complementary visual and textual evidence. At each reasoning round, a central planner selects an evidence acquisition action, specialized expert tools extract spatial and semantic observations as structured textual evidence, and a self-consistency validation mechanism examines this evidence along two dimensions, knowledge consistency against the input image and temporal consistency with prior validated findings, before updating the diagnostic state. Validated observations are admitted into the evolving state to condition subsequent planning, while insufficiently supported or conflicting findings are retained with corrective feedback that redirects the planner toward additional verification. We further introduce EndoAgentBench, a workflow-oriented benchmark comprising 6,132 question-answer pairs from 11 endoscopic datasets, to evaluate diagnostic agents across a comprehensive diagnostic chain, from fine-grained visual perception to high-level diagnostic reasoning. EndoCogniAgent achieves 85.23% overall accuracy on perception tasks and 71.13% clinical acceptance rate on reasoning tasks. Blinded clinician evaluation further shows consistent improvements in diagnostic response quality over the evaluated baselines.