eess.IVNov 9, 2026

Leveraging High-Activity Post-Therapeutic I-131 Scans for Deep Learning Reconstruction of Extremely Sparse Planar Images in Differentiated Thyroid Cancer

Authors: Boyang Pan, Hang Yang, Jianchen Pan, Cui Gan, Lanxi Zhang, Hongmin Li, Nan-Jie Gong

Organizations: Institute of Magnetic Resonance and Molecular Imaging in Medicine, East China Normal University, Shanghai, China · Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China · Nuclear Medicine Department, Southwest Hospital (the First Affiliated Hospital), Third Military Medical University (Army Medical University), Chongqing, China · RadioDynamic Medical, Shanghai, China

Abstract

Background: Diagnostic I-131 whole-body planar imaging in differentiated thyroid cancer (DTC) is count-limited by low administered activity, and quality worsens under rapid acquisition. Models trained on such data struggle because their targets lack photon statistics. Purpose: To test whether high-quality post-therapeutic (PT) I-131 scans can serve as superior training references for enhancing sparse diagnostic planar images, using transfer learning and input-image addition. Methods: In this single-center prospective study, 111 patients were enrolled in PT training (n = 19), diagnostic follow-up (FU) training (n = 58), and FU paired test (n = 34) cohorts. Five Restormer-based models were trained: FU_DLx2 on FU labels; PT_DLx2 transfer-learned on PT data; PT_DLx1+ and PT_DLx2+ with input-image addition; PT_DLx6 as a PT-only reference. Test-time processing used two-step denormalization and Poisson re-scaling to preserve noise statistics. Quality was assessed by PSNR, SSIM, and a blinded dual-reader evaluation of all 34 test-cohort patients. Results: PT_DLx2 achieved the highest PSNR (34.4 +/- 3.6 dB) and SSIM (0.81 +/- 0.07). PT_DLx1+ and PT_DLx2+ were comparable (33.8 and 33.3 dB; SSIM 0.80). FU_DLx2 ranked below the unprocessed fast scan (30.3 vs. 32.0 dB; 0.76 vs. 0.79). Subjectively, PT_DLx2+ scored highest in image quality (4.54 +/- 0.60) and diagnostic confidence (4.54 +/- 0.60), surpassing the reference standard (4.19 +/- 0.83 and 4.31 +/- 0.81; P = 0.005 and P = 0.008). FU_DLx2 and PT_DLx6 scored lowest. Conclusion: Count-rich PT scans provide effective training priors for reconstructing extremely sparse images. Input-image addition and cross-domain transfer learning from PT data outperformed direct training on count-limited diagnostic data, supporting 2x scan acceleration with quality matching or exceeding the unaccelerated standard scan for selected PT-derived configurations.

Explore similar work

Apr 16, 2026

CTSCAN: Evaluation Leakage in Chest CT Segmentation and a Reproducible Patient-Disjoint Benchmark

Reported chest CT segmentation performance can be strongly inflated when train and test partitions mix slices from the same study. We present CTSCAN, a reproducible multi-source chest CT benchmark and research stack designed to measure what survives under patient-disjoint evaluation. The current four-class artifact aggregates 89 cases from PleThora, MedSeg SIRM, and LongCIU, and we show that the original slice-PNG workflow induces near-complete case reuse across train, validation, and test. Using the playground environment, we run a multi-seed protocol sweep with the same FPN plus EfficientNet-B0 control configuration under slice-mixed and case-disjoint evaluation. Across 3 seeds and 12 epochs per seed, the slice-mixed protocol reaches 0.6665 foreground Dice and 0.5031 foreground IoU, whereas the case-disjoint protocol reaches 0.2066 Dice and 0.1181 IoU. Removing patient reuse therefore reduces foreground Dice by 0.4599 absolute (69.00% relative) and foreground IoU by 0.3850 absolute (76.52% relative). CTSCAN packages the corrected benchmark with deterministic split manifests, explicit weak-supervision controls, a scripted multi-seed protocol sweep, and reproducible figure generation, providing a reusable basis for patient-disjoint chest CT evaluation.
Jun 4, 2025

Generalizable dose denoising using diffusion transformer framework for pencil beam scanning proton therapy

Background and purpose: Intensity-modulated proton therapy (IMPT) enables conformal dose delivery for head and neck (H&N) cancers. However, its sensitivity to inter-fractional anatomical changes motivates online adaptations, where rapid and accurate Monte Carlo (MC) dose calculation remains a major bottleneck. Low-statistics MC simulations reduce computation time but introduce noise. This study aimed to develop a diffusion-transformer framework to recover high-statistics dose distributions from noisy MC simulations. Materials and methods: A diffusion-transformer-based dose denoising framework was developed. Eighty H&N patients were used for training and additional 10 H&N patients and 30 patients with lung, breast, and prostate cancers (10 per site) were used for evaluation. Noisy and high-statistics dose maps were generated using MCsquare. The model was trained using noisy dose maps and CT images as inputs and high-statistics dose maps as ground truth, with mean squared error, residual, regional mean absolute error (MAE), and dose-volume histogram (DVH) losses. Performance was evaluated using MAE, 3D gamma passing rates, and DVH indices. Results: Mean whole-body MAE ranged from 0.08 +/- 0.06 to 0.20 +/- 0.11 Gy (Relative Biological Effectiveness, RBE) (RBE = 1.1) across test cohorts. Mean whole-body 3 %/2 mm gamma passing rates ranged from 95.8 +/- 0.8 % to 97.6 +/- 0.9 %. DVH indices from high-statistics and predicted dose distributions showed close agreement for clinical target volumes and organs of interest. Conclusions: The diffusion-transformer-based framework denoised low-statistics MC dose distributions. Despite being trained on H&N data, the model generalized to lung, breast, and prostate cohorts without retraining.
Apr 8, 2026

Distilling Photon-Counting CT into Routine Chest CT through Clinically Validated Degradation Modeling

Photon-counting CT (PCCT) provides superior image quality with higher spatial resolution and lower noise compared to conventional energy-integrating CT (EICT), but its limited clinical availability restricts large-scale research and clinical deployment. To bridge this gap, we propose SUMI, a simulated degradation-to-enhancement method that learns to reverse realistic acquisition artifacts in low-quality EICT by leveraging high-quality PCCT as reference. Our central insight is to explicitly model realistic acquisition degradations, transforming PCCT into clinically plausible lower-quality counterparts and learning to invert this process. The simulated degradations were validated for clinical realism by board-certified radiologists, enabling faithful supervision without requiring paired acquisitions at scale. As outcomes of this technical contribution, we: (1) train a latent diffusion model on 1,046 PCCTs, using an autoencoder first pre-trained on both these PCCTs and 405,379 EICTs from 145 hospitals to extract general CT latent features that we release for reuse in other generative medical imaging tasks; (2) construct a large-scale dataset of over 17,316 publicly available EICTs enhanced to PCCT-like quality, with radiologist-validated voxel-wise annotations of airway trees, arteries, veins, lungs, and lobes; and (3) demonstrate substantial improvements: across external data, SUMI outperforms state-of-the-art image translation methods by 15% in SSIM and 20% in PSNR, improves radiologist-rated clinical utility in reader studies, and enhances downstream top-ranking lesion detection performance, increasing sensitivity by up to 15% and F1 score by up to 10%. Our results suggest that emerging imaging advances can be systematically distilled into routine EICT using limited high-quality scans as reference.