cs.RONov 9, 2026

Simulating Vein Compressibility for Ultrasound-Guided Femoral Access: Speed, Accuracy, and Phantom Validation

Authors: Amit Manicka, Laurent Coulon, Darwin Ang, Michael Loushin, Timothy M. Kowalewski

Organizations: Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota 55455, United States of America · Lightside Surgical, Bellevue, Washington 98005, United States of America · Healtcare Corporation of America, HCA HealthONE Trauma Quality Improvement Program Univ., Ocala, Florida · Visible Heart Laboratory, Department of Anesthesiology, University of Minnesota Medical School, Minneapolis, Minnesota 55455, United States of America

Abstract

In ultrasound-guided femoral access, probe pressure deforms the tissue and changes the vascular anatomy a robot observes. A simulator must reproduce these mechanics fast enough for robotic interaction, yet the computational effort needed for a clinically meaningful signal like vein collapse before artery is unclear. We test the feasibility of a physics-based simulation in NVIDIA's Isaac Sim for Healthcare, with Stable Neo-Hookean tissue solved by Vertex Block Descent on one GPU. A simulation of a low-fidelity cylindrical benchtop phantom with known geometry and mechanical properties, pressed by a robot, predicted its artery within 5 percentage points at every depth. It matched the vein within 3 points through 11 mm of a 25.4 mm press and followed the collapse behavior of the low-fidelity physical phantom. Across element size, time step, and solver iterations, wall clock time per frame scaled linearly with solver work, but accuracy did not improve with more work. The chosen setting reduced solver time per frame by a factor of 976, from 29,700 ms to 30.4 ms, while remaining within 1.03 points of the finest reference setting. The physics solver alone took 30.4 ms per frame, while the full stack, including ultrasound and graphics rendering, took 56.4 ms per frame. Finally, when seeded with realistic literature-based mechanical properties, the digital leg model compressed the vein far more than the artery at every setting, reproducing the expected clinical signal of vein collapse before artery, which is used to distinguish them. In total, these results suggest that the NVIDIA Isaac Sim platform may be suitable for augmenting reinforcement learning training or online simulation for autonomous femoral access with ultrasound.

Figures & tables

Explore similar work

May 30, 2026

An Exploratory Study into using Machine-Learning for Fast Step-by-step Emulation of Numerical Mechanical Thrombectomy Simulations for Ischemic Stroke

The treatment of ischemic stroke using mechanical thrombectomy involves difficult decisions under intense time constraints. Numerical physics simulations can in theory inform operators to make better decisions regarding treatment approaches and device selection, but are too slow to do so in practice. In this thesis, we investigate if current machine learning based surrogates can accurately emulate these simulations in a step-by-step manner while making them significantly faster. To do this we train three surrogate models on two simulations that involve a simplified aspiration procedure, with varying levels of geometric complexity. Our results show that two of our models accurately predict singular simulation steps and provide substantial speedups, especially when combined with specific data augmentations. However, the models showed a lack of stability when emulating simulations with complex geometries over longer time periods. Overall, this work provides a foundation for future studies to develop stable methods that scale to realistic numerical physics simulations of mechanical thrombectomy.
Aug 25, 2026

CRESSim-Neo: A Batched GPU Simulation Engine for Surgical Robotics and Robot Learning

We introduce CRESSim-Neo, a batched GPU simulation engine for surgical robotics and robot learning. CRESSim-Neo combines position-based simulation of rigid bodies, deformable tissues, fluids, and strands with batched rendering, surgery-specific sensing, and a GPU-resident data pipeline. The engine supports applications including tissue manipulation, fluid suction, suturing, cable-driven robots, and ultrasound image synthesis. Direct access to physics and rendering buffers enables GPU-resident robot learning and zero-copy PyTorch integration using DLPack. We demonstrate CRESSim-Neo across rigid-body, deformable-body, and fluid simulation tasks, including vision-based and surgical robot-learning scenarios. On an NVIDIA RTX 4090, the engine achieves up to 2.03 million environment steps per second for 8192 parallel CartPole environments, and scales to batched surgical scenarios involving tissue deformation, fluid interaction, and ultrasound sensing. Overall, CRESSim-Neo provides a unified and scalable platform for surgical simulation, synthetic data generation, and surgical robot learning.
Oct 13, 2026

RoboSimStudio: An Interactive Toolkit for Human and Agent Rapid Real2Sim of Robot Manipulation Tasks

It has been difficult to accurately model the physics of the interaction between a robot and the objects it manipulates, including contact mechanics, coupled contact dynamics, deformations, stiffness and friction. We present RoboSimStudio (RSS), an interactive toolkit that makes choices of solver, contact model, and physical parameters explicit and editable, allowing both humans and coding agents to quickly create and iteratively refine simulations based on observed physical behavior. We implement RSS with the open Newton physics simulation system and describe experiments with human-guided real2sim using (1) visual evaluation, (2) force-feedback and (3) agentic Real2Sim2Real. Code, video and additional information can be found on the project website: https://robosimstudio.github.io