cs.CVNov 9, 2026

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

Authors: Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori, Nicola Valsecchi, Nasiq Hasan, Elham Sadeghi, 

Organizations: Department of Ophthalmology, University of Pittsburgh school of Medicine, Pittsburgh · Department of Experimental and Clinical Medicine, Eye Clinic, Polytechnic University of Marche, Ancona, Italy · Ophthalmology Unit, Dipartimento di Scienze Mediche e Chirurgiche, Alma Mater Studiorum University of Bologna, Bologna, Italy. · IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy

Abstract

Background: Geographic atrophy (GA) is an advanced form of age-related macular degeneration (AMD). It causes irreversible vision loss due to progressive degeneration of the retinal pigment epithelium (RPE) and photoreceptors. Accurate segmentation of GA in en-face image is crucial for early diagnosis, monitoring disease progression, and developing personalized treatment strategies. However, existing deep learning approaches are typically evaluated using single architectures and single-device datasets, limiting insight into relative performance and cross-device robustness. Methods: We trained and systematically compared five deep learning architectures for GA segmentation: Nested U-Net, ResU-Net, nnUnet, Swin-Unet and MedSegDiff model, together with a thresholding based classical baseline. The models were trained on a dataset of en-face OCT images derived from 269 OCT volumes from two different devices, following a three-step preprocessing technique involving normalization and inpainting to enhance the quality of the en-face images. Results: On the fixed held-out validation set comprising OCT scans from both Cirrus (R) (Carl Zeiss Meditec, Inc., USA) and Spectralis (R) (Heidelberg Engineering, Germany) devices, nnUnet achieved the highest mean Dice similarity coefficient (DSC) of 0.8882 +/- 0.0033. The other models yielded the following Dice scores: Nested U-Net (0.7932 +/- 0.0423), ResU-Net (0.8453 +/- 0.0074), Swin-Unet (0.6886 +/- 0.0294), and Diffusion model (0.7959 +/- 0.0242). Conclusions: nnUnet framework, demonstrated most reliable performance for GA segmentation in en-face OCT under limited data conditions. It offers the best balance of accuracy, stability, and efficiency for GA quantification.

Explore similar work

Jun 30, 2026

Fully Automated High-Precision Segmentation of Retinal Atrophy and Ellipsoid Zone Thickness in OCT: A Reliable Tool for Real-World GA Monitoring

Geographic atrophy (GA) secondary to age-related macular degeneration (AMD) requires precise monitoring of relevant structural biomarkers to assess disease stage, progression, and treatment response. This paper presents a fully automated, deep learning-based framework for the high-precision, pixel-wise segmentation of key biomarkers in optical coherence tomography (OCT) imaging: retinal pigment epithelium (RPE) loss, ellipsoid zone (EZ) loss, and EZ thinning. The proposed pipeline uses three specialized semantic segmentation models to delineate RPE loss, EZ boundaries (including interruptions), and Bruch's membrane. To ensure robustness and generalizability, the models were developed on a diverse dataset of 298 SD-OCT volumes representing the full phenotypic spectrum of AMD (GA:222, intermediate AMD: 40, neovascular AMD: 17, healthy: 19) and validated on an independent external dataset (n=43). The comprehensive evaluation was further strengthened using additional datasets to assess repeatability, inter-reader reliability, the impact of B-scan density on measurement accuracy, and subgroup performance stratified by lesion size. Results demonstrated high segmentation accuracy (Dice RPE loss: 0.88, Dice EZ loss: 0.87, Pearson's r > 0.99). Total EZ thickness measurements exhibited a sub-pixel average deviation of 2.15 μmμm, and segmentation reliability was confirmed by a strong reproducibility score (ICC > 0.98). By accurately and consistently quantifying outer photoreceptor degeneration and RPE loss, this fully automated framework provides a highly reliable tool for GA assessment in both clinical trials and routine real-world ophthalmic care.
Jun 3, 2026

Deep Learning-assisted AMD Staging based on OCT and OCT Angiography

To develop and evaluate deep learning models for automated grading of age-related macular degeneration (AMD) severity using optical coherence tomography (OCT) and OCT angiography (OCTA) data. Two hundred seventy-one participants aged >= 50 years with varying AMD severities. Central macular 6 x 6 mm OCT/OCTA volumes were acquired using a swept-source OCTA system (SOLIX; Visionix/Optovue Inc., CA). AMD severity was graded into four stages (No AMD, Early AMD, Intermediate AMD, and Advanced AMD) according to the AREDS simplified severity scale. Three deep learning models were developed using different input modalities: (1) biomarker maps derived from segmented pathological features, including retinal fluid, drusen, geographic atrophy (GA), and macular neovascularization (MNV); (2) two-dimensional (2D) en face OCT and OCTA projections; and (3) three-dimensional (3D) OCT/OCTA volumes. EfficientNet-based architectures were trained using normalized inputs, data augmentation, and five-fold cross-validation. A total of 2,030 OCT/OCTA volumes from 351 eyes of 271 participants were analyzed. All models demonstrated strong AMD staging performance with substantial agreement with the reference standard (QWK >= 0.83). The biomarker-based model achieved the highest overall performance (QWK = 0.85 +/- 0.03, mean +/- standard deviation) and the best detection of early AMD (F1-score = 0.59 +/- 0.14). The 3D model achieved performance comparable to the 2D OCT/OCTA model (QWK = 0.83 +/- 0.04 vs. 0.83 +/- 0.09), while the 2D OCT/OCTA model showed the highest precision (0.79 +/- 0.06) and most accurately identified eyes without AMD. Deep learning models using OCT/OCTA data can accurately and automatically grade AMD severity. Among the evaluated approaches, the biomarker-based model provided the most balanced performance and showed particular value for early AMD detection.
Aug 11, 2026

Modelling Geographic Atrophy Progression using Implicit Neural Representations

Age-related Macular Degeneration (AMD) is the major cause of blindness in the Western world. Its late dry phase is characterised by irreversible atrophic areas, namely Geographic Atrophy (GA). Longitudinal Fundus Autofluorescence (FAF) image acquisitions are currently the main tool for assessing lesion growth over time at the image level. However, due to its highly individualised progression, the evolution of late AMD remains poorly understood. In this work, we propose using Implicit Neural Representations (INRs) to model GA progression at the individual level in a low-data setting. Our approach generates both FAF and GA segmentation at both past and future time points. Among the comparison models, our method achieves competitive segmentation quality across different scenarios, yielding the lowest Mean Absolute Error (MAE) for the GA lesion area and the highest DICE score, without sacrificing FAF image quality. The code is available at https://github.com/SimoneSarrocco/ga-progression-with-inrs.