cs.LGNov 10, 2026

Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data

Authors: Muntaqim Ahmed Raju, Ruizhe Ma, John W. Ramsay, David J. Cornell

Organizations: University of Massachusetts Lowell, Lowell, MA, USA · U.S. Army DEVCOM Soldier Center, Natick, MA, USA

Abstract

Heart rate (HR) forecasting may provide advance information about near-future cardiovascular response, potentially supporting physiological monitoring and workload-management decisions during ruck marching. However, robust model development is constrained by the difficulty of collecting large-scale ruck-march datasets, creating a scarce-data problem in which models must generalize across participants while adapting to individuals from limited personal data. To address this problem, we benchmark population-only training (POT), personalized-from-scratch training (PFST), and population-pretrained fine-tuning (PPFT) for HR forecasting during loaded ruck marching using data from eight active-duty U.S. Army medics across thirteen sessions. LSTM, Attention-LSTM, and CNN-LSTM backbones were evaluated against a persistence baseline at 30 s and 60 s horizons. Across all neural architectures and horizons, PPFT yielded lower mean MAE, RMSE, and endpoint MAE than both POT and PFST. Participant-level paired analysis after averaging across three training seeds showed that, relative to PFST, PPFT reduced trajectory MAE by 2.22-4.30 bpm and endpoint MAE by 1.24-2.88 bpm. All six trajectory-MAE comparisons remained significant after Holm adjustment (padjp_{adj} = 0.0469), while four of six endpoint-MAE comparisons remained significant after adjustment. At 30 s, persistence achieved the lowest MAE (3.555 ±\pm 1.274 bpm), while CNN-LSTM PPFT achieved the lowest RMSE (4.669 ±\pm 1.916 bpm); LSTM PPFT achieved the lowest endpoint MAE (5.093 ±\pm 2.365 bpm). At 60 s, Attention-LSTM PPFT achieved the lowest MAE (5.573 ±\pm 1.939 bpm) and RMSE (7.134 ±\pm 2.260 bpm), while CNN-LSTM PPFT achieved the lowest endpoint MAE (7.553 ±\pm 2.357 bpm). These results suggest that population pretraining followed by participant-specific fine-tuning may provide a practical strategy for scarce-data wearable HR forecasting.

Figures & tables

Explore similar work

Jul 22, 2026

Zero-Shot Heart Rate Variability Forecasting from Consumer Wearables Using Time Series Foundation Models

Short-term Heart Rate Variability (HRV) forecasting could provide clinicians with actionable lead time for detecting autonomic dysfunction and adverse cardiac events. Consumer wearable devices generate fragmented, artifact-rich HRV signals that challenge conventional forecasting approaches. In this study, we evaluated the forecasting ability of three Time Series Foundation Models (TSFMs), TimesFM, Chronos, and MOIRAI, against traditional baselines (Mean, Exponential Smoothing, and Exponentially Weighted Moving Average) on real-world wearable data collected from 49 healthy individuals. To address data fragmentation, we introduce a variability-preserving imputation method that augments linear interpolation with locally adaptive stochastic noise, retaining physiological dynamics essential for accurate forecasting. The results show that TSFMs outperformed all baselines without fine-tuning, achieving average Mean Absolute Scaled Error (MASE) between 0.81 and 0.87 across TSFMs and both context lengths (32 and 64 time steps), with Chronos and TimesFM as the top models, though MOIRAI showed limited gains over baselines. With up to a 2-hour forecast horizon, the results establish a baseline for TSFMs' performance on a real-world dataset, highlighting domain-specific fine-tuning as a promising direction for clinical deployment.
Oct 2, 2026

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.
Dec 23, 2024

WildPPG: A Real-World PPG Dataset of Long Continuous Recordings

Reflective photoplethysmography (PPG) has become the default sensing technique in wearable devices to monitor cardiac activity via a person's heart rate (HR). However, PPG-based HR estimates can be substantially impacted by factors such as the wearer's activities, sensor placement and resulting motion artifacts, as well as environmental characteristics such as temperature and ambient light. These and other factors can significantly impact and decrease HR prediction reliability. In this paper, we show that state-of-the-art HR estimation methods struggle when processing representative data from everyday activities in outdoor environments, likely because they rely on existing datasets that captured controlled conditions. We introduce a novel multimodal dataset and benchmark results for continuous PPG recordings during outdoor activities from 16 participants over 13.5 hours, captured from four wearable sensors, each worn at a different location on the body, totaling 216,hours. Our recordings include accelerometer, temperature, and altitude data, as well as a synchronized Lead I-based electrocardiogram for ground-truth HR references. Participants completed a round trip from Zurich to Jungfraujoch, a tall mountain in Switzerland over the course of one day. The trip included outdoor and indoor activities such as walking, hiking, stair climbing, eating, drinking, and resting at various temperatures and altitudes (up to 3,571,m above sea level) as well as using cars, trains, cable cars, and lifts for transport -- all of which impacted participants' physiological dynamics. We also present a novel method that estimates HR values more robustly in such real-world scenarios than existing baselines.