cs.LGNov 10, 2026

Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data

Authors: Muntaqim Ahmed Raju, Ruizhe Ma, John W. Ramsay, David J. Cornell

Organizations: University of Massachusetts Lowell, Lowell, MA, USA · U.S. Army DEVCOM Soldier Center, Natick, MA, USA

Abstract

Heart rate (HR) forecasting may provide advance information about near-future cardiovascular response, potentially supporting physiological monitoring and workload-management decisions during ruck marching. However, robust model development is constrained by the difficulty of collecting large-scale ruck-march datasets, creating a scarce-data problem in which models must generalize across participants while adapting to individuals from limited personal data. To address this problem, we benchmark population-only training (POT), personalized-from-scratch training (PFST), and population-pretrained fine-tuning (PPFT) for HR forecasting during loaded ruck marching using data from eight active-duty U.S. Army medics across thirteen sessions. LSTM, Attention-LSTM, and CNN-LSTM backbones were evaluated against a persistence baseline at 30 s and 60 s horizons. Across all neural architectures and horizons, PPFT yielded lower mean MAE, RMSE, and endpoint MAE than both POT and PFST. Participant-level paired analysis after averaging across three training seeds showed that, relative to PFST, PPFT reduced trajectory MAE by 2.22-4.30 bpm and endpoint MAE by 1.24-2.88 bpm. All six trajectory-MAE comparisons remained significant after Holm adjustment (padjp_{adj} = 0.0469), while four of six endpoint-MAE comparisons remained significant after adjustment. At 30 s, persistence achieved the lowest MAE (3.555 ±\pm 1.274 bpm), while CNN-LSTM PPFT achieved the lowest RMSE (4.669 ±\pm 1.916 bpm); LSTM PPFT achieved the lowest endpoint MAE (5.093 ±\pm 2.365 bpm). At 60 s, Attention-LSTM PPFT achieved the lowest MAE (5.573 ±\pm 1.939 bpm) and RMSE (7.134 ±\pm 2.260 bpm), while CNN-LSTM PPFT achieved the lowest endpoint MAE (7.553 ±\pm 2.357 bpm). These results suggest that population pretraining followed by participant-specific fine-tuning may provide a practical strategy for scarce-data wearable HR forecasting.

Figures & tables

Explore similar work

CardsList
  1. Zero-Shot Heart Rate Variability Forecasting from Consumer Wearables Using Time Series Foundation Models

    Jul 22, 2026Luukas Peräkylä, Fahad Sohrab, Ville Hautamäki +3Zero-Shot Time Series ForecastingTime Series Forecasting

  2. Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

    Oct 2, 2026Yuxuan Hu, Shilin Shan, Jianfei Yang +1Heart Rate EstimationmmWave Radar Sensing

  3. WildPPG: A Real-World PPG Dataset of Long Continuous Recordings

    Dec 23, 2024Manuel Meier, Berken Utku Demirel, Christian HolzHeart Rate EstimationPhotoplethysmography