econ.GNNov 12, 2026

Price co-movement and price information diverge across Nordic electricity zones after the energy crisis

Authors: My Thi Diem Phan, Tuyen Trung Truong, Hoai Phuong Ha, Dat Thanh Nguyen

Organizations: Department of Computer Science, UiT The Arctic University of Norway, P.O. Box 6050 Langnes, 9037 Tromsø, Norway · Department of Mathematics, University of Oslo, P.O. Box 1053 Blindern, 0316 Oslo, Norway · Faculty of Medicine, University of Oslo, P.O. Box 1078 Blindern, 0316 Oslo, Norway

Abstract

After the 2021-2022 energy crisis, day-ahead prices in Nordic bidding zones no longer move together. We ask whether this divergence also changes the information carried by prices. The answer matters for integrating variable renewable energy (VRE), because it can help identify where wind and solar forecasts are worth producing, publishing, and using. We measured the co-movement of each Norwegian and Swedish zone with Germany-Luxembourg (DE-LU) in 2018-2025. We then used a single model, selected on 2024 data, to forecast 2025 prices at 11:00 on the previous day and tested which inputs improved accuracy in each zone. The zones moved alike until 2019, but co-movement diverged in Sweden in 2020 and in Norway in 2021, and the split has persisted. In 2024, four southern zones co-moved strongly with DE-LU (intraday correlations of 0.54-0.71), while four northern zones co-moved weakly (0.25-0.30). Yet price information did not follow this split. Previous-day neighbouring prices reduced mean absolute error by at most 2.2% in any zone, equally in coupled and isolated zones. Removing the transmission system operators' wind and solar forecasts increased mean absolute error by at most 6% in Norway, 8-16% in Sweden, and 31% in DE-LU, and the ordering held in 2024. Within Norway, the value of these forecasts showed no detectable dependence on reservoir filling. The divergence in co-movement was therefore not matched by a divergence in price information, which differed mainly between national generation systems. Thus, a zone's coupling to the continent does not indicate the value of VRE forecasts there.

Figures & tables

Explore similar work

Apr 29, 2026

Electricity price forecasting across Norway's five bidding zones in the post-crisis era

Norway's electricity market is heavily dominated by hydropower, but the 2021-2022 energy crisis and stronger integration with Continental Europe have fundamentally altered price formation, reducing the reliability of forecasting models calibrated on historical data. Despite the critical need for updated models, a unified benchmark evaluating feature contributions across all structurally diverse Norwegian bidding zones remains lacking. Here we present a comprehensive evaluation of one-step-ahead forecasting of the Nord Pool market across all five Norwegian bidding zones. We constructed a multimodal hourly dataset spanning 2019-2025 and evaluated eight forecasting model families, including Light Gradient Boosting Machine (LightGBM), autoregressive models with exogenous variables, and advanced deep learning architectures, using a strictly causal test set. We implemented robust rolling-origin backtesting, leave-one-group-out feature ablation, and conditional regime analysis to dissect model performance and feature utility. Our results show that LightGBM achieves the best performance in every zone, with mean absolute error ranging from 1.60 to 5.58 euros per megawatt-hour, while a ridge-regularized autoregressive model with exogenous variables remains a highly competitive linear benchmark in northern zones. Feature ablation reveals that models relying solely on lagged prices and calendar variables achieve high accuracy and often match or closely approach the performance of the full multimodal model. However, conditional regime analysis demonstrates that external features like reservoir levels and gas prices remain crucial to stratify forecast errors, which consistently increase under stressed market regimes. This highlights the practical value of model interpretability and regime awareness for decision makers facing structural changes in market dynamics.
Oct 12, 2026

Cross-Market Meta-Learning for Electricity Price Forecasting

Day-ahead (DA) electricity price forecasting is usually posed per market, with a separate model fitted to each grid's own history. This caps accuracy: statistical and tree-based baselines saturate, while higher-capacity sequence models need more training data than a single market's few years of hourly prices can supply. Such methods also treat each node as an independent series, discarding the spatial dependencies induced by network topology and congestion. Because price formation across independent system operators (ISOs) is driven by shared physics and largely common market design, we instead treat cross-market history as a pretraining corpus. We present MetaGrid, a topology-aware transformer, meta-trained across markets so that a single zone-count-independent parameter set adapts to an unseen grid. On a leak-free benchmark of five U.S. ISOs, where every model receives the same prices, DA load forecasts and calendar features, MetaGrid attains the lowest average MAE, improving on the best baseline by 3.1% and on the same architecture trained from scratch by 7.7%.
Nov 5, 2026

EnergyBench: a live, gate-aligned benchmark of day-ahead forecasts for European power markets

Energy forecasting models are usually compared on backtests and fixed public datasets. Backtests can use data that did not yet exist when the forecast would have been made, and a fixed test set, reused across studies and possibly contained in the pretraining data of foundation models, invites overfitting to the benchmark. EnergyBench evaluates every entry live instead. Each day at 11:30 CET/CEST, thirty minutes before the day-ahead (SDAC) gate closes, every model forecasts the next day's price, wind and solar generation and load on the 15-minute grid for six bidding zones (BE, NL, FR, DE-LU, DK1, DK2). Unlike existing live benchmarks, EnergyBench runs the models itself, on one information set that it freezes at the cut-off and publishes, including three numerical weather prediction models, so that foundation models can be compared with and without the same weather covariates under the actual market deadline. Errors are pooled per series against a seasonal-naive baseline, and models are ranked by a Bradley-Terry rating on the Elo scale with a day-bootstrap interval. The field spans baselines, linear and gradient-boosted models on the frozen weather, eighteen time-series foundation models from eleven families, ensembles, and the grid operators' own forecasts. Over the first thirty-two live days, the covariates reduced the error of each of the ten foundation models run with and without them by 37-51% on matched races (64-73% on wind, 48-61% on solar). Used zero-shot, these models match or outperform a LightGBM model trained on the same covariates. Model size, from 3M to 331M parameters, has a much smaller effect, and median ensembles of the covariate models rank highest. The grid operators' pre-gate forecasts remain ahead on wind and solar, where the best single foundation models have 16-22% more error; on load the gap is 4-6%, within the intervals.